• 제목/요약/키워드: Underground water

검색결과 1,335건 처리시간 0.028초

규산질계 분말형 도포방수재의 내투수성 성능평가 연구 (Hydrostatic Pressure Resistance Performance Testing of Cement Mixed Siliceous Powder Waterproofing Coationgs)

  • 박소영;권시원;김수연;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.31-32
    • /
    • 2018
  • Lately, cement mixed siliceous powder waterproofing coating has been used as a waterproofing material in the wet environment condition of an underground concrete structure. Underground is exposed to environmental influences such as pressure of ground water, pressure of soil. However, the quality standard for pressure (water pressure, earth pressure) is not specified in the specification of the cement mixed siliceous powder waterproofing coating. Therefore, in this study, the permeability test was carried out based on the assumption that the durability should be verified in consideration of the environmental aspects of the material in actual field. As a result of the test, the permeability was generated from the inorganic single type material, but it was caused by the sealing failure and the test error, and the permeability was not generated in most of the materials. The results of this study will be analyzed by reviewing the physical properties of the material, and the research direction will be resumed.

  • PDF

지하수의 영향을 고려한 지하공동구조체의 동적응답 (Dynamic Response of Underground Openings Considering the Effect of Water Saturation)

  • 김선훈;김광진
    • 한국전산구조공학회논문집
    • /
    • 제14권3호
    • /
    • pp.391-399
    • /
    • 2001
  • 본 논문에서는 지하수의 영향을 고려하여 발파로 인한 폭발하중에 대한 지하공동구조체의 3차원 동적해석을 수행하였다. 지하공동 주변 암반체는 13.5%의 공극율을 갖는 석회암으로 가정하였으며, 동일한 폭발하중에 대해 주변 암반체의 공극이 완전히 건조한 경우와 이 공극이 완전 포화된 경우로 나누어 해석을 수행하였다. 수치해석결과 지하공동구조체가 포화된 암반체에 위치하는 경우가 건조한 암반체에 위치하는 경우에 비해 속도, 변위, 응력이 모두 크게 발생하였다. 그리고 포화된 암반체의 지하공동구조체 부근에서는 전단파괴의 가능성이 발생함을 확인할 수 있었다.

  • PDF

GIS를 이용한 농업시설물 데이터베이스관리시스템 개발 (Development of Database Management System for Agriculture Facilities Using Geographic Information System)

  • 안원태;최석근
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.570-579
    • /
    • 2021
  • 현재의 농어촌은 고령화로 인한 인력 및 장비부족, 농산물 가격하락 등 여러 환경이 갈수록 열악해지고 있는 실정이다. 본 연구는 이러한 문제를 해결하기 위하여 수 많은 농업기반시설물 중 중요 관리대상인 관정, 양수장, 취입보 등을 대상으로 데이터베이스 구축하여 점검, 고장 및 수리 등의 이력사항을 관리하기 위하여 수행되었다. 특히, 관정의 경우에는 무분별한 설치와 공간정보 부재로 인하여 경제적 손실 및 환경오염 등의 문제를 야기시키기 때문에 수문지질도, 수맥도, 지하수 심도 등의 공간정보를 이용하여 관정의 최적위치를 결정하였다. 따라서, 본 연구는 시스템 개발을 통하여 농촌지역에 산재되어 있는 수 많은 시설물들을 효율적으로 관리할 수 있었고, 공간정보를 이용하여 14개 관정에 대한 현황을 분석한 결과 6개 지점에서의 위치정보가 잘못된 것으로 나타났으나, 현장조사결과 1개 지점에서는 수맥도 분석이 잘못된 것으로 분석되었다.

지반응력 및 지하수위 변화가 지하철구조물 안정성에 미치는 영향 사례연구 (A Case Study on the Effects on Underground Structure due to Changes in the Groundwater Level and Ground Stress)

  • 정지승;이선길;이규영;정해욱;김홍주
    • 한국지반환경공학회 논문집
    • /
    • 제16권9호
    • /
    • pp.13-21
    • /
    • 2015
  • 최근 도심지에서는 지하수위 변화에 따른 지반침하 및 싱크홀이 다수 발생함에 따라 안정된 지하수위 관리에 대한 필요성이 대두되고 있다. 본 연구에서는 지반의 지하수위 및 유효응력의 변화가 지하철구조물의 안정성에 미치는 영향을 파악하기 위해 버스환승센터 조성 구간 부지 하부로 통과하는 지하철구조물을 대상으로 연구를 수행하였다. 지하철구조물의 안정성 평가를 위해 수행된 연계해석 및 구조해석 결과 지하수위 저하에 따른 구조물의 안정성은 확보되는 것으로 평가되었다. 이와 같이 도심지 터파기 시공 전 지하수위 변화에 따른 지반거동 및 인접구조물에 미치는 영향을 사전에 검토하고 예측하여 효율적인 공사관리가 이루어져야 할 것이다.

다수의 부구간으로 나누어지는 트로프간 접수냉 전력케이불의 열해석에 관한 연구 (A Study on the Thermal Analysis of Indirect Water Cooled Power Cables Laid within Trough devided into Several Sub-Sections)

  • 문영현;김백;이태식
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.703-711
    • /
    • 1992
  • As the underground area of the metropolitan becomes denser recently, an introduction of forced cooling system is under study to maximize the carrying capacity of existing cables in tunnels. Indirect water cooling system laid within trough will probably be adopted for the next 345KV class underground power cables in this country. The system covers a distance of 1.5-3.0Km for one water cooling interval and one water cooling interval is composed of several sub-sections that have different thermal analysis conditions. Thus the distribution of temperature in each sub-section is described by different conditions in general. In this paper a method that can accurately match the temperature of the coolant in the boundary between sub-sections has been suggested. An algorithm to find the temperature distributions effectively in the thermal system has also been presented. A computer program using this method has been tested in a smaple system and the results have shown the usefulness of this program.

  • PDF

연안해수와 지하해수를 사용하는 제주 넙치 양식장의 수질과 미생물 변동 (Investigation of water qualities and microbials on the flow-through olive flounder, Paralichthys olivaceus farms using coastal seawater and underground seawater in Jeju)

  • 김유희
    • 수산해양기술연구
    • /
    • 제58권1호
    • /
    • pp.59-67
    • /
    • 2022
  • This study assessed the levels of water qualities and microbials contamination of inland olive flounder farms in Jeju in the summers from 2015 to 2017. Three farms (A-C) located in a concentrated area using mixing coastal seawater and underground seawater and one farm (D) located in an independent area using only coastal seawater were selected. Total ammonia nitrogen (TAN) reached a maximum of 0.898 ± 1.024 mg/L as N in the coastal seawater of A-C, which was close to the limit of the water quality management goal of the fish farm. TAN in the influent from A-C was up to three times higher than that of D, so that the discharged water did not spread to a wide range area along the coast and continued to affect the influent. TAN of the effluent in A-C increased by 2.7-4.6 times compared to the influent, resulting in serious self-pollution in the flounder farm. Heterotrophic marine bacteria in the influent of A-C was about 600 times higher than D, and the discharge of A-C was increased by about 30 times compared to the influent.

지하 열에너지 저장 기술 및 스웨덴 암반공동내 열수 저장 사례 (Technologies of Underground Thermal Energy Storage (UTES) and Swedish Case for Hot Water)

  • 박도현;김형목;류동우;최병희;선우춘;한공창
    • 터널과지하공간
    • /
    • 제22권1호
    • /
    • pp.1-11
    • /
    • 2012
  • 열에너지 저장은 고온 또는 저온의 열에너지를 임시 저장하는 것으로서 에너지 수요와 공급 사이의 불균형을 줄일 수 있고, 이를 통해 에너지를 절약하고 에너지 이용효율을 향상시킬 수 있다. 특히 간헐적으로 에너지를 생산하는 신재생에너지의 경우 에너지 저장 장치와의 조합은 필수적이다. 또한 지하 암반의 낮은 열전도도와 높은 열용량을 이용하여 지하에 열에너지를 저장하는 경우 열손실을 최소화하여 추가적인 효율 향상이 기대된다. 본 고에서는 지하 열에너지 저장 기술을 조사 분석하고 스웨덴에 암반공동내 열에너지 저장 사례를 소개하였다.

지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 - (Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.128-137
    • /
    • 2002
  • 개발된 알루히트를 이용하여 지하수 이용 열교환기를 개발하였다. 시작기는 600mm, 700mm 알루히트 19개의 끝을 U자 용접을 하여 지하수가 직렬흐름이 되도록 2가지로 제작하였다. 성능시험은 개방된 공간에서 지하수 유량과 공기양의 변화를 주면서 상온에서 실시하였다. 1. 시작기의 열전달 계수는 33~156(W/m2℃) 범위로 나타나 설계가정 값에 잘 일치하는 것으로 판단되었다. 2. 열전달 면적이 증가할수록, 지하수 입·출구의 온도 차이가 클수록, 공기의 입·출구 온도 차이가 클수록, 또 송풍량이 증가할수록 에너지 전달량이 증가하였다. 3. 지하수 입·출구 온도 차이가 6℃ 이고 송풍량이 6,000m3/h일 때 전달 열용량은 6,825W였으며, 공기의 입·출구 온도 차이는 25.8℃에서 23.2℃로 -2.6℃의 강화 효과가 있었고, 대류열전달계수는 88.5W/m2℃ 였다. 4. 지하수 입·출구 온도 차이가 2℃ 이고 송풍량이 4,000m3/h일 때 전달 열용량은 2,625W으로 작았지만, 공기의 입·출구 온도 차이는 27℃에서 22.5℃로 -4.5℃의 강화 효과가 있었고, 대류열전달계수는 33.6W/m2℃였다. 5. 시작기 I, II, III의 전달 열용량 데이터 각각의 상관계수 R2은 0.9141, 0.8935, 0.9393이었으며, 공기유량이 6,000m3/h, 5,000m3/h, 4,000m3/h일 때 각각의 데이터 상관계수 R2은 0.9513, 0.9414, 0.9003으로 신뢰할 수 있었다.

LPG 지하저장기지 수평 수벽공의 클로깅 현상 발생시 지하수위 및 주입수량, 삼출수량의 변화양상에 관한 실험적 연구 (An Experimental Study on Groundwater Head, Injection Water Flowrate and Seepage Water Flowrate under Clogging State of Underground Storage)

  • 한충용;강주명
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.101-105
    • /
    • 1997
  • LPG 지하저장기지에서 클로깅 현상이 발생할 경우 저장공동 주위의 지하수위가 설계된 수치보다 낮아져 저장물이 누출되므로 이에 대한 감지가 필수적이라 할 수 있다. 따라서 본 연구에서는 클로깅 현상이 실제로 발생하였을 경우 저장기지에서 관측할 수 있는 관측인자인 공동주변 지하수위, 수벽공 주입수량, 공동 삼출수량들의 변화양상을 고찰하기 위하여 지하저장기지를 모사한 모형실험장비를 제작하여 각 인자들의 변화 측정실험을 수행하였다. 클로깅 발생시 관측인자의 변화양상은 다음과 같다. 지하수위는 공동의 압력이 커짐에 따라 증가하고 클로깅이 심할수록 감소하는데, 클로깅 발생을 지하수위 변화에 의해서 보다 잘 감지하려면 공동의 압력을 가능한 낮게 하고, 공동 운영 초기의 지하수위와 현재 운영 상태의 지하수위를 비교해 보는 것이 바람직하다. 클로깅에 의한 지하수위의 감소는 수벽공의 압력이 커질수록 다소 둔화된다 현탁물질에 의한 클로깅이 심할수록 주입수량과 삼출수량은 선형적으로 감소하는데 주입수량의 감소율이 삼출수량의 감소율보다 크게 나타난다.

  • PDF

기존 도시의 홍수저감을 위한 우수관거 배수용량 증대 및 지하 빗물저류조 설치효과 비교 분석 (Comparative Analysis of the Storm Sewer Expansion Methodology and Underground Rainwater Storage Tanks for Urban Flood Control)

  • 이호열;서규태;이택순
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.754-761
    • /
    • 2013
  • Urban floods are usually caused by the lack of drainage capacity. Hence, sewer capacity expansion methodology by replacing small pipes with bigger ones is primarily applied as a flood control measure. However, this approach is often unreasonable because of the costs and time involved. Thus, the installation of underground rainwater storage tanks with the two advantages of flood control and water conservation is proposed. This study compared the effectiveness of flood control by both the sewer expansion methodology and rainwater storage tanks using the Storm Water Management Model. Three cases were simulated in this study. The first case analyzed flood reduction by the storm sewer expansion methodology. The simulation results indicate that the overflow volume from manholes was reduced by 49% with this methodology. The second case analyzed flood reduction by installation of rainwater storage tanks. The simulation results indicate that the overflow volume was reduced by 62%. However, these two cases could not prevent urban floods completely. Hence, the third case analyzed the joint application of the storm sewer expansion methodology and rainwater storage tanks. In this simulation, flooding did not occur. Consequently, the results of this study clearly show that underground rainwater storage tanks are more effective for flood control than capacity expansion of storm sewer. Furthermore, the joint application of these two flood control measures is more effective than their separate application.