• 제목/요약/키워드: Underground power transmission system

검색결과 114건 처리시간 0.044초

무선센서를 이용한 지하전력구의 케이블 접속함 표면온도감시시스템 개발 (A Development of Surface Temperature Monitoring System for Underground Tunnel Cable Joint using Wireless Sensor)

  • 김영일;송재주;신진호;이봉재;조선구
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1879-1884
    • /
    • 2007
  • In the electric power industry, it is important that the supply of energy must be guaranteed. Many power utilities control and supervise the transmission line to avoid power failures. In case of underground tunnel, some troubles are reported in cable joint. To stabilize the power, it is needed to monitor the cable joint. Many researches of cable joint monitoring have been going on by partial discharge measurement and temperature measurement using optical cable. These methods need much cost to install and maintain, so it is only used in critical transmission line. In this research, we use wireless sensor technology, because of its low cost and easy installation. We develop the temperature monitoring system for cable joint. Temperature sensor is installed on the surface of cable joint and sends data to server through router node using wireless network. Generally Ad hoc routing is searched in wireless network. However, in this research, we design the static linear routing mechanism, which is suitable for electric power line monitoring and analyze the life time of the sensor node by measuring the amount of the battery consumption.

EMTP를 이용한 송전케이블 시스전압 분석 (Underground Transmission Cable Sheath Voltage Analysis Using EMTP)

  • 오동수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.428-430
    • /
    • 2000
  • This paper describes under-ground transmission cable sheath voltage by using EMTP and proposes a new design method for calculating cable sheath voltage in steady state. The cross bonding system of power cable is modeled on ${\pi}$ equivalent circuit and the sheath voltage(current) of cable can be analyzed with comparing to conventional method.

  • PDF

전력구내 지중케이블 강제냉각에서의 적정냉각구간에 관한 연구 (A Study on the Optimum Cooling Span of the Underground Power Transmission Cable Equipped by a Forced Cooling System)

  • 이재헌;정상호;김재근;박만홍
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.49-62
    • /
    • 1990
  • The forced cooling system has been widely applied to passing more electric current in the underground power transmission cable technology. In this paper, the optimum cooling span of the in-trough-indirect water cooling method within an electric tunnel was investigated. A parametric study was performed for the cable currents, the coolant flow rates, and the coolant inlet temperatures. As a result, the temperature of the inlet air has been found as the most important parameter in determination of the optimum cooling span.

  • PDF

지중송전계통에서 불평형요소에 따른 뇌과전압 해석 (Analysis of lightning overvoltage with unbalanced element in Underground Transmission Cable System)

  • 강지원;이동일;김재승;김양상;정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.718-720
    • /
    • 2005
  • This paper analyses the transient phenomena against lightning surge on underground power cable systems. For analysis, several actual underground power cable systems are modeled using ATP. In lightning surge strokes, the various unbalanced conditions including the length of crossbonded lead, the breakdown of CCPU and distance unbalance are considered. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

  • PDF

275kV XLPE절연 전력케이블의 해외프로젝트 적용 (Application of 275kV XLPE Power Cables for Overseas Protect)

  • 권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1736-1738
    • /
    • 2002
  • Oil-filled power cables and XLPE power cables have been globally applied for extra-high-voltage underground power transmission lines. The application of XLPE cables for the transmission lines have been largely increased at the domestic and overseas projects because of some issues. O.F cables have some week points, related with the issues of the environmental pollution and the needed maintenance work, even though they have been applied for several ten years and their reliability has been proven. Meanwhile, the demands on XLPE power cables increase as their manufacturing technologies have been improved and their simplicity of installations has been focused on. In Korea, for the first time, the 275kV XLPE cable is to be applied at an overseas power plant project. This paper introduces the project profile, the design of the XLPE cable and its accessories, the cable system design and the installation design.

  • PDF

PSCAD/EMTDC를 이용한 전력케이블 고장현상에 판한 연구 (A Study on Power Cable Fault Using PSCAD/EMTDC)

  • 김점식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.868-870
    • /
    • 1996
  • This paper describes the faun phenomena by the simulation in power system including underground transmission power cable. Studying on fault phenomena is a very important part to decide the circuit breaker, protective relay and system configuration. Simulation was carried out in several different model system depended upon cable kinds using PSCAD/EMTDC, which is one of the transient program. The simulated results show the possibility to analyze transient phenomena for the cable system.

  • PDF

실계통 345kV 지중송전선 대칭좌표 임피던스의 해석 (Analysis of Sequence Impedances of 345kV Cable Transmission Systems)

  • 최종기;안용호;윤용범;오세일;곽양호;이명희
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

지중 송전관로 되메움용 순환골재의 현장실증시험을 통한 적용성 평가 (Assessment on Applicability of Recycled Aggregates for Backfill Materials of Underground Transmission Lines Based on Field Demonstration Tests)

  • 강성철;이강렬;안태봉
    • 한국건설순환자원학회논문집
    • /
    • 제3권1호
    • /
    • pp.72-83
    • /
    • 2015
  • 지중 송전선은 전기저항에 의한 발열현상이 늘 있으며, 그 주변의 되메움재를 통하여 열을 방출하게 된다. 따라서, 송전관로의 설계에는 발생하는 열을 주변 지반이 효과적으로 외부에 전달하여, 열적 안정성을 확보하는 것이 매우 중요한 설계 요소가 된다. 본 연구에서는 지중 송전관로 되메움재용 순환골재의 현장 적용성을 향상시키기 위하여, 순환골재의 품질기준 및 시공기준을 제시하고, 현장 실증시험을 통하여 송전관로의 열안정성을 분석하였다. 현장 실증시험에서는 순환골재 두 종류와 현재 되메움재로 사용하고 있는 모래의 열적 거동을 비교하였다. 시험 결과, 순환골재는 시간경과와 관로에서의 이격거리에 따라 온도와 함수비 변화가 모래와 유사하게 나타났다. 따라서 순환골재는 지중 송전관로 되메움재로서 일반 모래를 대체하여 적용 가능할 것으로 판단된다.

국내외 지중송전시스템의 과도상태 해석 (Analysis of transient state between Korea and Japan in Underground Transmission Cable System)

  • 강지원;장태인;홍동석;이동일;정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.462-464
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge between Korea and Japan on underground power cable systems. For analysis, find proper earthing resistance of neutral grounding system adopted in Japan. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

  • PDF

154kV 지중 방식층용 ZnO소자 및 서지 보호장치 성능 (The Performance of ZnO Varistors and Surge Protector for 154kV Underground Cable)

  • 조한구;한동회;윤한수;이종혁;장태봉;이형구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.248-250
    • /
    • 2001
  • The surge protector is crucial power apparatus to guarantee the safe operation of power transmission of underground cable which can effectively restrain the overvoltage and inductive lightning stroke in power system. This paper describes the results of a study on the performance of ZnO varistors and surge protector for 154 kV underground cable. And, the influence of water tight and insulating performance was evaluated through such as surge protector of the armored design.

  • PDF