• Title/Summary/Keyword: Underground parking facilities

Search Result 33, Processing Time 0.031 seconds

Crime Prevention Through Environmental Design of Underground Parking in Commercial Facilities - Field survey of Underground Parking Spaces in Department stores, Large Discount Mart and Mixed Used Commercial Facilities - (상업시설 지하주차장의 CPTED계획요소에 관한 연구 - 대형마트와 백화점, 복합상업시설 지하주차장 현장조사 -)

  • Min, Young Hee;Kwon, Ju-Young;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.129-137
    • /
    • 2016
  • Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.

Energy Saving Potentials of Ventilation Controls Based on Real-time Vehicle Detection in Underground Parking Facilities

  • Cho, Hong-Jae;Park, Joon-Young;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.331-340
    • /
    • 2013
  • The main topic of this paper is to show a possibility of indoor air quality enhancement and the fan energy savings in underground parking facilities by applying the demand-controlled ventilation (DCV) strategy based on the real-time variation of the traffic load. The established ventilation rate is estimated by considering the passing distance, CO emission rate, idling time of a vehicle, and the floor area of the parking facility. However, they are hard to be integrated into the real-time DCV control. As a solution to this problem, the minimum ventilation rate per a single vehicle is derived in this research based on the actual ventilation data acquired from several existing underground parking facilities. And then its applicability to the DCV based on the real-time variation of the traffic load is verified by simulating the real-time carbon monoxide concentration variation. The energy saving potentials of the proposed DCV strategy is also checked by comparing it with those for the current underground parking facility ventilation systems found in the open literature.

A Study on Inhabitants' Mental Survey for Apartment House's Underground Parking Lots (공동주택 지하주차장 계획을 위한 거주자 의식조사연구)

  • Jeong, Young-Suk;Cho, Sung-Woo;Oh, Se-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.113-117
    • /
    • 2009
  • By statistics in August, 2007, currently Korean motors registration number broke through 16 million units. The demand of motors is being increased as time goes on and the demand of parking lot within apartment complex is increased together. Therefore, it is inevitable to expand underground parking lots. Underground parking lots have relatively weaker environment than the ground and physical/psychological problems as distance far away from the main building, fear for vehicle damage and crimes, impure air, darkness and closed feeling take place. Underground parking lots also occupy a lot of area ratio within apartment complex and have a lot of effects on other facilities. Therefore, underground parking lots are neglected for all that underground parking lots have deep relations with satisfaction for public space within apartment complex. Accordingly, the purpose of the study is to make reference materials when underground parking lots are planned by grasping satisfaction of underground parking lots through inhabitants'mental survey and surveying preferential location and requirements of parking lots.

  • PDF

A Research on the Reconstruction Project for the Main Gate Area of the U University Campus (대학 정문 진입부 재구성을 통한 캠퍼스 환경개선에 관한 연구 -경남 소재 U대학의 주차 및 복합시설 구성을 중심으로-)

  • Lee, Kwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • In order to solve the current shortage of parking spaces, and redesign the main gate area of the U University, the research investigated some cases of other schools located in Seoul which actively constructed multi-purpose building structures. Those schools are considered to be good samples showing their efforts to fulfill the needs of more parking spaces in their campuses, and to cover with the growing needs of multi-functioned facilities accommodating services of academic affairs, reading room spaces, and amenities. With the investigation, the research finded out the current trends of campus developments from the sample schools, such as underground parking facilities connected with multi-purpose buildings along the main arteries of campuses. Following the trends the research thoroughly examined the present conditions of our school and tried to make some possible alternatives for the facilities. Under the conditions, the research suggested 1)to construct underground parking lots accepting around 1,000 cars under the ivory tower square located in front of University Administration Building, 2)to develop a big-scaled open square at the university main gate, and 3)to build a multi-purpose structure along the main street of the campus, which included administration services, studying spaces, and some commercial facilities.

A Study on the Plans of Apartments Underground Parking lots to Prevent Women's Criminal fear Psychology - Focused on apartment design competitions of Suwon A region - (여성의 범죄불안심리를 고려한 공동주택의 지하주차장 계획 연구 - 수원A지구 공동주택 현상설계를 중심으로 -)

  • Li, Jin-Ji;Kim, Nam-Hyo
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.104-114
    • /
    • 2009
  • The purpose of study was understanding necessity of environment design for underground parking lot in residential design plan and grasping design plans of 'Activity Support' that considerate women, exclude women's unsecured feeling at underground parking lot. The inquiry analyzed 6 design plan in design competition that considerate women according to precede studies, a theory of CPTED, a design guide for wayfinding, and survey. A ramp, circulation, entrance, lighting, ventilation, and space design plan are proceed on this study The result are as below. First, a rectilinear figure ramp suits entrance plan on the circulation, but if it is not possible, cross-using of rectilinear and curvilinear figure ramp plan is desirable. Second, on the circulation plan, vehicles circulation plan and equality parking distribution plan got accomplished generally, and help senses of direction because it is planed network systemize. On a large scale underground parking lot, simplify parking circulation to convenience entrance and exit for weak in sense of direction. Third, the shape and material that‘s environmentally conscious will be in use to the entrance plan. As the first stage to the underground, artwork that women prefer can modulate the rejection of underground space. Forth, natural lighting system and ventilation can make the environment-friendly space, decrease the women’s rejection to the underground, it can also keep a natural watch on the space. Fifth, on the space design plan, it can use bright and comfortable design of wall and ground to decrease the women‘s rejection, also it is useful to the sense of direction. LED indirect lighting plan that 58.7% of women prefers on survey reflects women’s state of desire that bright and atmosphere. In addition, proper use of plans that subsidiary facilities, rest area with Sunken, and nature-friendly material can minimize differences of underground and ground parking lot.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

Numerical Simulation on Ventilation Characteristics of an Underground Bus Parking Lot (버스전용 지하주차장의 환기 특성에 관한 수치해석적 연구)

  • Seung, Sam-Sun;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.179-184
    • /
    • 2007
  • In this paper, the ventilation characteristics of an underground parking lot with 17 buses has been investigated for two cases by computational fluid dynamics. It has been found that the average concentration of CO and $NO_x$ gas in the parking lot were 1.3 and 0.3 ppm respectively, when four buses operated. When the fifteen vehicles stopped in the parking lot, the average concentration of CO and $NO_x$ gas was 2.9 and 0.8 ppm respectively. The average concentration of two pollutants$(CO,\;NO_x)$ are lower than the standard values. Therefore the facilities and its location is proper to ventilation.

  • PDF

Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities (다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화)

  • Choi, Im-Cho;Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

The Concentrations of TSp, PM10 and Heavy Metal at Underground parking Lots of Public Facilities in Taegu City (대구시 공중이용시설 지하주차장의 총부유먼지, 호흡성먼지 및 중금속 농도)

  • 이현주;정재열;이종영;송희봉;홍성철
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.22-29
    • /
    • 2000
  • This study was performed to investigate the concentrations of TSP, PM10 and heavy metals(Pb, Cd,Hg, Ni, Zn) of underground parking lots in Taegu city. The samples were collected from 3 department stores and 1 central park in the winter and the summer, 1997. The samples of 3 department stores were divided into sale period and non-sale period in the winter and the summer. The concentrations of TSP and PM10 were 109.6±1.5㎍/㎥ and 93.3±1.5㎍/㎥. In TSP, the zinc was the highest level, 287.16±1.5ng/㎥ and the cadmium was the lowest, 2.4±2.1ng/㎥ and in PM10, the zinc was the highest level, 193.6±1.5ng/㎥ and the cadmium was the lowest, 0.6±3.9ng/㎥. The correlation coefficient between the concentration of TSP and PM10 was 0.982(p<0.05). The correlation coefficients of corresponding heavy metal in TSP and PM10 were 0.863 for lead, 0.617 for mercury, 0.890 for nickel and 0.850 for zinc(p<0.05). The concentrations of TSP, PM10 and cadmium of PM10 in the winter were higher than those of the summer. However, the concentration of Hg of PM10 in the summer was higher than that of the winter. The concentrations of TSP and PM10 in sale period was higher than those of non-sale period and the concentrations of heavy metal in TSP and PM10 were not significantly different between sale and non-sale period. The proportions of PM10 to TSP were above 60% in dust, lead, nickel, and zinc and less than 40% in cadmium and mercury. The concentrations of TSP, PM10 and heavy metal in the underground parking lots were comparatively lower than those of general atmosphere. However, this kind of research to PM10 in the underground parking lots must be continued because it is very important particulate matter that affects human beng's health.

  • PDF

A study on the concentration of formaldehyde in public Facilities in Cheon-An area (천안지역 일부 다중이용시설의 포름알데히드 농도에 관한 연구)

  • Jeon, Hye-li;Jo, Su-Yeon;Jo, Hye-Ran;Cho, Tae-Jin;Park, Jong-An;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • This study was conducted at a Terminal, a Parking Lot, an Underground shopping center, a Funeral hall and a Hospital waiting room of Cheon An area in August 2008 to examine the concentration level of HCHO(formaldehyde). The concentration level of the remodeled sites were $39.4\;{\pm}\;12.0\;{\mu}g/m^3$ in the terminal, $32.7\;{\pm}\;7.3\;{\mu}g/m^3$ in the parking, and $97.8\;{\pm}\;29.4\;{\mu}g/m^3$ in the underground shopping center. The underground shopping center had the highest level and followed by the terminal and the parking. On the contrary, the site remodeling had the level of $17.7\;{\pm}\;12.4\;{\mu}g/m^3$ in the funeral hall and $17.9\;{\pm}\;0.6\;{\mu}g/m^3$ in the hospital waiting room. The funeral hall had highest level than that of the hospital waiting room. Both the remodeled sites and the not remodeled site had concentration level of HCHO below the standard level, but it was higher in the remodeled sites. There were no relations among the HCHO, the temperature and the humidity in facilities of Cheon An area.