Browse > Article

A study on the concentration of formaldehyde in public Facilities in Cheon-An area  

Jeon, Hye-li (Department of Environmental Health Science, Soonchunhyang University)
Jo, Su-Yeon (Department of Environmental Health Science, Soonchunhyang University)
Jo, Hye-Ran (Department of Environmental Health Science, Soonchunhyang University)
Cho, Tae-Jin (Department of Environmental Health Science, Soonchunhyang University)
Park, Jong-An (Department of Environmental Health Science, Soonchunhyang University)
Son, Bu-Soon (Department of Environmental Health Science, Soonchunhyang University)
Publication Information
Journal of environmental and Sanitary engineering / v.24, no.2, 2009 , pp. 1-8 More about this Journal
Abstract
This study was conducted at a Terminal, a Parking Lot, an Underground shopping center, a Funeral hall and a Hospital waiting room of Cheon An area in August 2008 to examine the concentration level of HCHO(formaldehyde). The concentration level of the remodeled sites were $39.4\;{\pm}\;12.0\;{\mu}g/m^3$ in the terminal, $32.7\;{\pm}\;7.3\;{\mu}g/m^3$ in the parking, and $97.8\;{\pm}\;29.4\;{\mu}g/m^3$ in the underground shopping center. The underground shopping center had the highest level and followed by the terminal and the parking. On the contrary, the site remodeling had the level of $17.7\;{\pm}\;12.4\;{\mu}g/m^3$ in the funeral hall and $17.9\;{\pm}\;0.6\;{\mu}g/m^3$ in the hospital waiting room. The funeral hall had highest level than that of the hospital waiting room. Both the remodeled sites and the not remodeled site had concentration level of HCHO below the standard level, but it was higher in the remodeled sites. There were no relations among the HCHO, the temperature and the humidity in facilities of Cheon An area.
Keywords
HCHO; remodel level; terminal;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 정규철 : 산업독성편람, 서울, 신광출판사, 442-445, 1994
2 환경부 : 실내공간 실내공기오염 특성 및 관리방법 연구, 연구보고서, 2002
3 정연희, 최상준 : 인천지역 일부 학교의 실내 및 대기 중 HCHO 농도 평가, 한국환경보건학회지, 33(5), 372-378, 2007   과학기술학회마을   DOI
4 홍은주, 전용택, 이치원, 노선진, 이종대, 송미라, 손부순 : 충남지역 초.중.고등학교 실내 공기 중 HCHO의 농도분포에 관한 연구, 대한위생학회지, 22(2), 53-60, 2007   과학기술학회마을   PUBMED
5 McCarthy, J. F., Bearg, D. W. and Spengler, J. D. : Assessment of indoor aIr quality, indoor air pollution: A Health Perspective, 82-108, 1998
6 Spengler, J. D. Sources and concentrations of indoor air pollution. indoor air pollution, A Health Perspective, J.M. Samet and J.D. Spengler, Eds. The Johns Hopkins University Press, London, 33-67, 1991
7 윤홍식, 정지연, 이광용, 박동욱, 박두용 : 유아교육시설의 위치 및 실내.실외에 따른 HCHO 농도 변화, 한국환경보건학회지, 30(3), 259-263, 2004   과학기술학회마을
8 노동부 : 산업보건기준에 관한 규칙 노동부령 제 195호, 2003
9 하권철 : 경남지역 지하생활공간 중 미량 유해물질인 HCHO의 농도 분포 특성, 한국환경보건학회지, 30(5), 353-357, 2004   과학기술학회마을
10 변상훈, 김영환, 손종렬, 문경환 : 아파트 실내에서 시간경과에 따른 HCHO 의 농도조사 Journal of health Science & Medical Technology, 28(1), 50-54, 2002
11 홍성철, 조혜미, 조태진, 이치원, 정용택, 손부순 : 충남 지역 미적용 다중이용시설의 실내공기질에 관한 연구, 환경위생공학회지, 23(2) 35-45, 2008   과학기술학회마을   PUBMED
12 신동천, 양지연, 임영욱, 김호현, 박성은, 홍천수 : 실내환경오염이 거주자의 건강에 미치는 영향평가 및 예방모델개발, 한국대기환경학회, 35, 69-70, 2003
13 문경환, 변상훈, 최달웅, 이은일, 오은하, 김영환 : 실내 공기 중 일부 알데히드류에 대한 위해도 평가 - 일부 주택 및 아토피 환자 주택을 대상으로- 32(1), 19-26, 2006   과학기술학회마을
14 Hines, A. L. : Indoor air quality and control, New Jersey, PTR Prentice Hall, 1993
15 환경부 : 다중이용시설 등의 실내공기질 공정시험법, 2003
16 서종원 : 작업장 및 실내공간 공기오염물질 중 VOCs와 HCHO(HCHO) 에 대한 유해성 평가, 설비저널, 31(6), 2002   과학기술학회마을
17 Ryan, P. B. and Lambert, W. E. : Personal exposure to indoor air pollution. indoor air pollution, A Health perspective, 109-127, 1994
18 Harrje, D. T. : Building dynamics and indoor air quality. indoor air pollution: A Health Perspective, J.M. Samet and J.D. Spengler, Eds. The Johns Hopkins University Press, London, 68-81, 1991