A study on the basic experiment of performance criteria for application of pipe bursting method in actual field (Pipe Bursting 공법의 적용성 검토를 위한 주요 성능평가 항목의 기초실험연구)

  • Park, Sangbong;Kim, Kibum;Seo, Jeewon;Park, Sanghyuk;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.435-443
    • /
    • 2018
  • Most of aged water supply pipes have been replaced by the open cut method. However, this method has some limitations because water pipes, in many cases, are buried together with other underground facilities or are buried in the middle of high-traffic roads or in narrow alleyways where boring machines cannot be used. This research developed a pipe bursting device for small diameter pipes that enables pipe replacement without excavating the ground, by the busting of existing buried pipes followed by the traction and insertion of new pipes. As a results of examining the field applicability of the developed device, PE pipes and PVC pipes required the tractive force of 413.65~665.69 kgf and 457.43~791.35 kgf respectively, plus an additional 30 % tractive force per elbow. The proper number of bursting head was demonstrated that the connection of more than 2 heads could secure a stable bending radius of 15D. The developed device can be improved through field experiments involving various pipe types and pipe diameters, as well as presence/absence of elbow, so as to be utilized regardless of diverse variables according to the conditions of the soils surrounding existing pipes.

A Study on the Waste Incinerator Location Problem in Seoul (서울시 쓰레기 소각장 입지에 관한 연구)

  • 이금숙;이희연
    • Journal of the Korean Regional Science Association
    • /
    • v.14 no.1
    • /
    • pp.91-107
    • /
    • 1998
  • Waste disposal problem is one of the most important social welfare indicators in urban area, because the volume of waste generated from urban area is remarkable. So far most waste of Seoul has been disposed at landfills. However, this landifill disposal method is confronted with several difficulties in recent. As public concern on environmental problem increases and autonomy system is settled down, local community people of the landfills refuse to receive the waste produced other places any more. It brought reginal confliction problem between waste sending and receiving by refusing to accept waste from certain region. Furthermore, it is difficult to find another place to fill up the waste, while the existing landfiis is reached at the limit in the near future. In terms of environmental aspects landfill method is not the best way to dispose waste. It contaminates the soil and ground/underground water by leaking water containing many serious pollutants as well as offensive oder. In terms of equity, this waste disposal method is not fair. Environmental pollution causes damage to residence near to the landfills, while the waste produced other places. In order to satisfy the equity aspect, the waste generated a region should be disposed within the region. Incineration of Waste has been provided as the alternative. Government plans to construct waste incinerator in every anatomy, so the waste produced by local community is disposed within their local autonomous area. However, the location decision is not easy, since waste incinerator is one of the facilities to the community people. We can not apply the existing location models for this problem, because they show strong NIMBY phenomenon for the location. The location of waste incinerator should be determined very carefully with consideration of various location factors and criteria. This study proposes a methodology for determining the location of the waste incinerators by utilizing GIS, which is a power research tool for location decision where various geographical factors related. We drive the location factors which should be considered in the determination of waste incinerators. They involve environmental, socio-economic, and institutional factors. In first, we eliminate the area which is located within the environmental location criteria such as slope, fault line, distance to river, and then eliminate ares which is conflict with the social and institutional criteria.

  • PDF

Execution Case Study on the Explosive Demolition of a Large-Section RC Special Structure (대단면 철근콘크리트 특수구조물 발파해체 시공 사례)

  • Park, Hoon;Suk, Chul-Gi
    • Tunnel and Underground Space
    • /
    • v.19 no.5
    • /
    • pp.397-406
    • /
    • 2009
  • Recently, the number of industrial structures that must be demolished due to structural deterioration and unsatisfactory functional conditions has been increased. To minimize environmental hazardous factors created during the process of demolition, the explosive demolition method has been applied increasingly. This execution case was intended to describe an application of the explosive demolition method to the demolition of a Crusher & Screen structure, which was a large-section reinforced concrete special structure. It was deemed necessary due to its structural deterioration and unsatisfactory functional condition. Various pre-weakening processes and blasting patterns were applied to the large-section reinforced concrete members, and to reduce blasting vibration and impact vibration, time intervals were established for blasting in the same column and for blasting between blasting blocks. By applying the explosive demolition method to the demolition of a large-section reinforced concrete special structure, the explosive demolition was completed safely and efficiently, without causing any damage to surrounding facilities.

Hydraulic Analysis of Tailing Dam using GIS (GIS 기법을 이용한 광미댐 수문 분석)

  • Song, Won-Jyong;Heo, Sung;Kim, Tae-Heok
    • Tunnel and Underground Space
    • /
    • v.18 no.5
    • /
    • pp.375-385
    • /
    • 2008
  • Hydraulic analysis in a dam that has a single outlet of water can be made through a simple comparison between the total precipitation and the volume of discharged water. In case of tailing dams this estimation could yield an error because several drainage facilities are worked independently as well as simultaneously. In this research, a capability of the drainage system in the tailing dam of the old Sangdong Mine was analysed by the means of GIS technic. As a result of this study, it was expected that in the normal working condition of the whole drainage system, the flooding of water over the dam should not occur in spite of the consecutive precipitation during one hour with an intensity of 80.31 mm/hr, a probable precipitation within 100 years. It was, however, revealed that, if the drainage system did not work completely, the water could flood over the dam when the total precipitation reached 251.1 mm.

How Phenolic Composites were chosen - In Case of England (2) (페놀 컴포지트 실용화의 길 - 영국의 경우 (CASE STUDY 2))

  • Nomaguchi, Kanemasa;Forsdyke, Ken L.;Brown, Denver E.
    • Composites Research
    • /
    • v.17 no.2
    • /
    • pp.41-48
    • /
    • 2004
  • "Phenolic composite", one of safety composites was chosen to build rolling stock in England while it was applied to building materials in London Underground facilities. This paper was written by Mr. Denver E. Brown. He emphasizes, from visibility and toxicity points of view, phenolic is the best and Mr. Forsdyke says, there is no question, passenger's lives are No. 1 issue, material recycling is not No.1! not No.1!

A fundamental study on the sulphate-resistant mortar using waste glass fine powder and meta-kaolin according to various fine aggregates (잔골재 종류에 따른 폐유리 미분말 및 메타카올린을 사용한 내황산염 모르타르에 관한 기초적 연구)

  • Jeong, Dongwhan;Park, Junhui;Ahn, Taeho;Park, Yeongsik;Sho, Kwangho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.3
    • /
    • pp.115-121
    • /
    • 2017
  • The degradation of the concrete due to deterioration factors, such as corrosion of steel bars, cracks and structural strength of reinforced concrete structures, is a social problem. Especially, concrete structures constructed in seawater, underground water, waste water treatment facilities and sewerage are subject to chemical attack by acid and sulphate. Therefore, this study was conducted to compare sulfated glass and fine aggregate of slag using waste glass fine powder and meta kaolin. The results showed that the slag fine aggregate showed better sulfate resistance than the river sand, and the fine powder of waste glass showed the best performance at 3 % displacement.

A Study on the Performance and Dehumidification Load of an HVAC System for Conservation of Ancient Tombs (고분 공조시스템의 운전특성 및 제습부하에 관한 연구)

  • Park, Jin-Yang;Ko, Seok-Bo;Jun, Hee-Ho;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.253-262
    • /
    • 2007
  • Although the importance of good conservation of historical sites including ancient royal tombs is well aware, still not much attention has been paid for facilities to realize it. There are numerous ancient royal tombs spread in Korean peninsula which are opened and some of them are selectively on display for public access. However, the conservation measures of these sites have not been seriously investigated. Even the level of understanding of the underground environment of tombs is not satisfactory. In the present study, we focus on the dehumidification loads to maintain appropriate conservation conditions in terms of temperature and humidity. Two experimental tombs different in size were built in KNU (Kongju National University) campus with the dimensions ($L{\times}W{\times}H$) of $1.0m{\times}2.8m{\times}1.0m\;and\;1.3m{\times}3.0m{\time}1.2m$, respectively, HVAC systems are installed to maintain a suitable condition for conservation, i.e., $22{\pm}2^{\circ}C$ in temperature and $55{\pm}5%$ in relative humidity. The condensed water are measured to estimate the dehumidification loads while the temperature and the humidity inside the tombs were maintained within the specified range.

Enterprise GIS Implementation Plan at Local Government: from Data Centric to Service Centric Architecture (지방자치단체의 Enterprise GIS 고도화전략: 데이터중심에서 서비스중심 아키텍처로)

  • Kang, Young-Ok
    • Spatial Information Research
    • /
    • v.15 no.3
    • /
    • pp.347-362
    • /
    • 2007
  • GIS has been rapidly developed since 1995 when the Ministry of Construction and Transportation started the First National GIS Construction Project and built large scale topographic map at local governments level. From that time local governments have been built several application system such as road management system, waterworks management system, sewer management system, underground facilities management system, and urban planning information system, etc. However, the construction of GIS application system at different department level brings the problem of data sharing and overlapping database construction. To overcome this environment Enterprise GIS concepts has been introduced. In case of Seoul Metropolitan government Spatial Data Warehouse have been constructed. However, Seoul Metropolitan government still have the problem of inactive use of GIS system and adaption to the rapidly changing information environment. This study aims to present Strategic plan to uggrade Enterprise GIS concenpt from data centric to service centric architecture at local government level.

  • PDF

Pattern Classification of Volatile Organic Compounds in Various Indoor Environment (다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류)

  • Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min;Kim, Ki-Youn;Kim, Jong-Cheol;Jun, Hyung-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.49-56
    • /
    • 2007
  • The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.

Design of the Railbeam Lengths at the Roadbed (철도 레일빔 설계법에 대한 연구)

  • Jung, Hyuksang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • This paper deals with contents on the estimation of rail beam from the geotechnical engineering aspect. Rail beam is reinforced rail installed on the inside and outside of rail to prevent differential settlement during the construction period of railroad crossing construction. Such rail beam is frequently being installed to ensure stability of existing railroad facilities because of increasing constructions of underground structures crossing railroad in recent. However, there is a difficulty in design due to lack of design standard on rail beam length. Furthermore, derailing accidents are also occurring as a result of rail beam length shortage. Accordingly, this paper presented flow chart based on the classification into soil ground and bedrock ground for the rail beam length estimation. In addition, case study was conducted on rail combination and location through which effective rail combination and location were ensured.