• Title/Summary/Keyword: Underground facilities

Search Result 632, Processing Time 0.03 seconds

Plan Planing of Apartment Remodelling by Resident's Needs Analysis (보급형 공동주택의 리모델링 계획안의 제안)

  • Ban, Hye-Min;Kang, Jae-Woo;Choi, Jung-Min
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.492-496
    • /
    • 2006
  • This study has the purpose a remodeling plan of apartment complexes in residential areas. Based on the analysis on characteristics of circumstance surrounding it and economic gains for the residents who live in the apartments, this study suggests a concrete model to accomplish the purpose. The apartment in Nowon-gu was studied and some apartments which have same characteristics with the target of remodeling plan were interviewed and answered the questionnaire. To grasp the functions required and planning factors of apartment's remodeling, the questionnaire focused on the residents' request in each levels of their own entire hosing complex, just a building in the hosing complex area, and their own household. The conclusion is, (1) The major problems of common apartment complexes were serious aging, insufficient everyday life facilities and high rate of the residents' dissatisfaction. (2) The study suggests remodeling plans of an apartment complexes in each levels of their own entire hosing complex, just a building in the hosing complex area, and their own household, such as, underground parking area, tree-planting of first and top areas, improvement of a housing floor plan, a view of the front side, and so on.

  • PDF

Efficiency Evaluation of Operating Railroad with Subway Cabin Air Purifier (도시철도 객실 공기정화장치(SCAP)의 운행차량 효율평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;NamGoong, Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1303-1308
    • /
    • 2011
  • In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.

  • PDF

Field Application of a Double Filtration Process to Control Fine Dust in a Metro Subway Station (도시 지하역사 미세먼지제어를 위한 이중여과장치의 현장적용 연구)

  • Park, Haewoo;Kim, Wooram;Jo, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.625-633
    • /
    • 2013
  • This study attempted to find an alternative method for fine dust control in the pre-exiting facilities of metro-subway stations. A new double-layer design was proposed for the MVAC (mechanical ventilation and air control) system. Several filter lay-outs were combined a pre-filter with electret filter (EF), electret bundle filter (EBF), or electret pleated filter (EPF), and were then examined focusing on the collection efficiency of particulate matters and pressure drop across the filter layers. The experimental results from the lab and field tests showed the best collection efficiency with EPF, which achieved 85% for $PM_{10}$ and 55% for $PM_{2.5}$. It was also found from the long term field test that the new filter lay-out could provide quite consistent dust level particularly in underground platform regardless of external condition.

Attribute Data Management for Developing the Database of a 3D Earthwork BIM System (3D 토공 BIM 시스템 데이터베이스 구축을 위한 속성 데이터 관리)

  • Moon, Sungwoo;Seo, Jongwon
    • Journal of KIBIM
    • /
    • v.6 no.4
    • /
    • pp.27-34
    • /
    • 2016
  • A Building Information Model (BIM) is an attempt to simulate the process of building structures in a three-dimensional (3D) digital space. While the technology is usually applied to structured buildings, bridges, and underground facilities, it is rarely applied to an unstructured environment of earthwork operations. If a BIM is used for earthworks, the 3D simulation can be used for construction equipment guidance and earthwork management. This paper presents a real-time, 3D earthwork BIM that provides a 3D graphical simulation of excavators in conjunction with geographic modeling. Developing a real-time, 3D earthwork BIM requires handling a variety of factors, such as geographical information and vehicular movement. This paper mainly focuses on the management of these attributes and provides a database design for storing and retrieving data. In an example application, a prototype of the 3D earthwork BIM is presented to understand what it would provide when used during earthwork operations at a construction site.

Combination of engineering geological data and numerical modeling results to classify the tunnel route based on the groundwater seepage

  • Aalianvari, A.
    • Geomechanics and Engineering
    • /
    • v.13 no.4
    • /
    • pp.671-683
    • /
    • 2017
  • Groundwater control is a significant issue in most underground construction. An estimate of the inflow rate is required to size the pumping system, and treatment plant facilities for construction planning and cost assessment. An estimate of the excavation-induced drawdown of the initial groundwater level is required to evaluate potential environmental impacts. Analytical and empirical methods used in current engineering practice do not adequately account for the effect of the jointed-rock-mass anisotropy and heterogeneity. The impact of geostructural anisotropy of fractured rocks on tunnel inflows is addressed and the limitations of analytical solutions assuming isotropic hydraulic conductivity are discussed. In this paper the unexcavated Zagros tunnel route has been classified from groundwater flow point of view based on the combination of observed water inflow and numerical modeling results. Results show that, in this hard rock tunnel, flow usually concentrates in some areas, and much of the tunnel is dry. So the remaining unexcavated Zagros tunnel route has been categorized into three categories including high Risk, moderately risk and low risk. Results show that around 60 m of tunnel (3%) length can conduit the large amount of water into tunnel and categorized into high risk zone and about 45% of tunnel route has moderately risk. The reason is that, in this tunnel, most of the water flows in rock fractures and fractures typically occur in a clustered pattern rather than in a regular or random pattern.

A study on the realtime renewal and update of digital map using general survey (일반측량 성과도를 활용한 수치지도의 실시간 수정갱신 체계화 연구)

  • Lee Sang-Gil;Kwon Jay-Hyoun;Yang Hyo-Jin;Jeon Jae-Han
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.393-398
    • /
    • 2006
  • Currently, 54 kinds of digital maps are provided by National Geographic Information Clearinghouse and the majority of those maps are based on aerial photographs or satellite image. The digital maps which symbolize and simplifies the topography and objects from ortho-photos does not reflect the objects 'shapes and facilities' changes. Especially, underground structures and complex building shapes are not correctly identifies by ortho-photos. Furthermore, the 1/1,000 and 1/500-1/2,500 maps for urban area produced by some local government or public organizations have detailed information with high precision, it is not easy to update the information due to the frequent changes of structures in the city. Although some efforts to solve this problem such as conducting field survey and shorten the survey period were tried, it is not the fundamental solution due to the high cost. Therefore, in this study, a realtime renewal and update of digital map using general survey are suggested. By assigning absolute coordinates to the general survey products and matching with digital maps, it is possible to update the digital map economically and rapidly. In addition, it is suggested that the construction of DB for general survey and sharing among survey companies to solve the duplicated survey.

  • PDF

A Study on Mechanical Behaviors of Granite and Sandstone at Low Temperature (저온하에서의 화강암, 사암의 역학적 거동에 관한 연구)

  • 안경문;박연준;이희근
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.91-99
    • /
    • 1997
  • To stabilize the energy price, the more storage facilities of energy are required and among the storage methods of LPG and LNG, the method of storage at low temperature under normal confining pressure is considered. It is needed to understand the mechanical and thermal characteristics of rock under temperature variation so that the behaviors of rock can be predicted. In this paper, the variation of the rock charateristics of the Hwangdeung granite and the Boryung sandstone is studied at low temperature. The mechanical characteristics of rock under low temperatures are that as temperature decreased, unaxial compression strength and Young's modulus increased for Hwangdeung granite; strength and Young's modulus in wet condition were greater than those in dry condition. In the case of Boryung sandstone, as temperature decreases unaxial compression strength and Young's modulus increase but decrease below -10$0^{\circ}C$ in dry condition and below -16$0^{\circ}C$ in wet condtion. The mechanical characteristics of rock after cooling to previous temperature and thawing are that uniaxial compression strength and Young's modulus decrease as temperature decreases. Uniaxial compression strength and Young's modulus in wet conditon decrease more than those in dry condition. Brazilian tension strength decreases as temperature decreases.

  • PDF

Computation of Underground Storm Water Storage Facilities Volume for Reducing the Flood Damage in Urban Area (도시침수저감을 위한 지하저류조 용량 산정)

  • Han, Kun-Yeun;Son, In-Ho;Lee, Sang-Yeob;Im, Jae-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1007-1011
    • /
    • 2009
  • 도시지역에 있어서 홍수피해의 직접적인 원인으로는 외수의 범람에 의한 침수와 내수 배제 불량에 의한 침수피해로 구분할 수 있는데 최근 도시지역에 발생하는 홍수피해의 대부분은 외수의 직접 범람에 의한 피해보다는 각종 수리구조물의 배제능력 부족이나 방류지점에서의 배수위의 영향으로 인한 내수의 배제 불량에 기인한 피해가 증가하는 추세이다. 또한 최근 도시지역에 홍수피해를 유발하고 있는 강우의 특징은 단시간에 많은 강우가 집중하여 발생하는 국지성 집중호우로 단시간 내에 수공구조물의 기능을 마비시킴으로써 침수피해를 가중시키는 경향이 있으므로 배수시설 설계 시 이러한 강우의 특성과 도시유출 특성에 대한 고려가 요구되며 중요 시설물에 대해서는 설계빈도의 상향조정이 필요하다. 본 연구에서는 기존 도시유역에 적용되고 있는 강우-유출모형의 기본이론의 장 단점을 검토하여 본 연구의 목적과 용도에 가장 적합하다고 판단되는 SWMM 모형을 선정하여 적용하였다. 대구 서구 비산 7동 배수구역의 유출모의를 실시한바, 향후 경제적 편익을 고려하고, 정확한 실측 유량자료 값을 산정, 관거 내 유속을 방해하는 토사 등 보다 정확한 관거자료, 모의에 사용하는 각종 매개 변수값의 정확도를 높인다면 인위적인 배수계통을 가지는 도시유역에서의 각종 풍수해에 피해를 최소화 할 수 있는 보다 합리적인 방재대책 수립에 큰 도움을 줄 것으로 판단된다.

  • PDF

Review of National Standards for Allowable Limit of Blast Vibration on Structures (구조물에 대한 국외 발파진동 허용 규제기준 분석)

  • Ryu Chang-Ha
    • Explosives and Blasting
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2005
  • Blast-induced ground vibration nay cause an environmental impact such as neighbour's complaints or damage on adjacent structures and facilities. Complaints associated with blasting have often become a target of public grievances. One of the difficulties to solve the problem is that we do not have a national standard for the acceptance level of blast-induced ground vibration. A peak particle velocity criterion, which was suggested for urbane underground construction, has often been widely used. Efforts have been made to establish more rational criteria. It seems that differing cultures have often differing thresholds of the toleration of vibration, and that technical data or rational grounds for establishing the limits are hardly provided. In this paper, national standards for allowable limit of blast vibration were presented and discussed.

Numerical Analysis of Utility Tunnel Movement under Reclamation Ground (매립지반 지하공동구의 수평이동원인에 대한 수치해석적 분석)

  • Yoon, Woo Hyun;Hwang, Chulsung
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.35-40
    • /
    • 2013
  • Recently reclamation land is largely developed to utilize the land according to economic growth. The soil of landfill is soft, low shear strength, which makes it difficult to use the equipment. A large movement is occurred on the utility tunnel under construction. The inclined land with high water level and underground facilities are widely distributed and the excess pore water pressure may occur under construction similarly to this study. Some different conditions are made to design result, such as 4m of soil piling near the construction area, heavy rainfall during 2nd excavation that may cause flow liquefaction. To analyze the cause of transverse lateral movement, Three dimensional analysis are performed to four load cases, which is original design condition, flow liquefaction by heavy rainfall, unsymmetric lateral soil pressure, and both of them simultaneously. Ten steps of full construction stage, 1st excavation for utility tunnel, construction of utility tunnel, 1st refill, piling soil from 1m to 4 m, 2nd excavation for drainage culvert, liquefaction around the utility tunnel, construction of drainage culvert and 2nd refill, are take into account to investigate the cause of movement.