• Title/Summary/Keyword: Underground cables

Search Result 244, Processing Time 0.025 seconds

Analysis of Electromagnetic Field Around Distribution Line (배전선로 주변에서의 전자계 분포 해석)

  • Kwon, Myung-Rak
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.672-676
    • /
    • 2017
  • Electrical energy is playing an increasingly vital role as the primary energy source in everyday life. With the increase in electric power consumption, power facilities are under an increasing stress and must operate at a high capacity. Consequently, the demand for electric power cables in power transmission and distribution lines is rapidly increasing. Underground distribution lines have been steadily replacing the aboveground lines owing to the increase in electric power demand and the need to increase the supply voltage. In addition to line damage, worker safety is of primary concern in this type of underground infrastructure. In this study, to improve the safety of workers dealing with underground transmission lines, we analyzed the electromagnetic field generated around the distribution line and determined the basic criteria for developing a device that can detect a live underground line.

An Improvement of Optical Fiber Composite Power Cable On-Line Monitoring System for Underground Distribution Network (지중 배전계통 적용을 위한 광복합 케이블 실시간 감시시스템 개선)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Park, Jung-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.77-83
    • /
    • 2012
  • Since power system is switching to smart grid, on-line monitoring technology has become necessary for underground distribution power cable. Therefore, the application of DTS(Distributed Temperature Sensing) technology using OFCPC(Optical Fiber Composite Power Cable) capable of monitoring underground distribution power cables has been developed. These can bring about reductions in faults and increases in operating capacity of underground distribution system. To date, the test-bed of optical fiber composite power cable on-line monitoring system has been constructed. Then, matters to be improved have been drawn through verification experiments. This paper presents the improvement and experiment results of the optical fiber composite power cable on-line monitoring system to apply to underground distribution lines in the field.

Evaluation of Jacket Compounds for Underground Distribution Power Cables (지중 배전케이블용 자켓 컴파운드의 특성평가)

  • 한재홍;송일근;김동명;이재봉;정창수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.687-694
    • /
    • 2002
  • In order to replace the jacket material for URD power cables, the 6 kinds of polyethylene compounds were manufactured and evaluated. The characteristics of the compounds were investigated by water vapor transmission (WVT) test, thermal and mechanical test. In WVT test, all the polyethylene compounds showed the superior water resistance to conventional PVC. The molecular structure and density of polyethylene play an important role in WVT. Also, the polyethylene compounds showed the suitable characteristics in thermal and mechanical test. Especially, the linear polyethylene compounds showed the superior characteristics to LDPE ones. Due to the fillers in compounds, the abrasion resistance was decreased and the cut-through resistance was increased. From this study, it can be considered that the polyethylene compounds may be suitable to jacket material for URD power cables.

A Study on Fault Detection Method in Underground Cables using the Detecting Electro Magnetic Wave and Acoustic Signal (전자파의 음향신호측정에 의한 지중 케이블의 고장점 검출기법에 관한 연구)

  • Min, Kyoung-Rae;Kim, Hun;Yoon, Yong-Han;Kim, Jae-Chul;Song, Ho-Yub
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1357-1359
    • /
    • 1999
  • This paper presents fault detection in cables. We developed the device for detecting pinpoint location of faults in power cables using acoustic method. The proposed device consists of hardware and software for the fault detection. Using the device, we explain how to detect the pinpoint of faults and introduce that the other method use the time delay between electro-magnetic and acoustic signals for the pinpoint of the faults.

  • PDF

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

A Study on the Reduction Factor of the Permissible Current-Carrying Capability of Underground Transmission Power Cables installed in Free Air (기중 다회선 부설에 대한 송전 케이블의 허용전류 저감계수에 관한 연구)

  • Jeong, S.H.;Kim, D.K.;Choi, S.B.;Lee, D.I.;Kang, J.W.;Gwak, B.M.;Tack, E.G.;Yoon, H.H.;Kim, J.S.;Park, J.H.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.343-345
    • /
    • 2001
  • This paper calculates the reduction factors of JCS 168E standard and IEC pub 287-2-2 according to installing groups of cables in a tunnel in Korean, respectively. Also, this paper proposes a method fat calculating reduction factors for groups of cables in free air.

  • PDF

A Study on Diagnosis of The Energized Status of 22.9kV Multigrounded Underground Power Cable (22.9kV 다중 접지 지중 전력 케이블의 가압 상태 진단에 관한 기초 연구)

  • Kim, Chang-Gyo;Hong, Jin-Su;Jeong, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.699-703
    • /
    • 1999
  • An experimental study to identify the energized status of the 22.9kV underground power cable by the detection of vibration has been performed. We have derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The relative amplitudes of the cable vibration according to the energized status of the cable were calculated by computer simulation. The cable vibration can also be picked up by accelerometer. A prototype was tested on the underground distribution system in Chonan substation, KEPCO. Comparison between simulation results and field test results was performed. The results showed that the energized status of the calble can be identified by measuring the vibration of the cable using accelerometer.

  • PDF

The line impedance calculation and measurement of the underground transmission cable (지중 송전 케이블 선로임피던스 계산 및 실측)

  • Kim, Nam-Yul;Kim, Joung-Yun;Heo, Hoi-Deok;Lee, Su-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.405-407
    • /
    • 2006
  • The power system analysis based on the accurate impedance of the individual underground cable, which is the inter connected to a large power system, is required. A study on calculation method of impedance allowable current for underground cables. furthermore, various methods of bonding and earthing the sheath have been used for the purpose of eliminating or reducing the sheath losses. the effectes of bonding and earthing must be includied in impedances. therefore, the subject of predicting thermal performance of soil and cable systems has been received increasing attension. for these problems, this paper describes a general formulation of impedance that is based on the effect of crossbonding and earthing of the sheath on the 66kV, 132kV and 220kV underground cable systems. also the work is presented, for calculating the temperature rise of power cable and soil.

  • PDF

Evaluation of Construction Applicability for Slurry Backfill Materials of Underground Power Cable (지중송전관로 유동화 뒷채움재의 시공성 평가)

  • Kim, Dae-Hong;Cho, Hwa-Kyung;Oh, Gi-Dae;Lee, Dae-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1068-1075
    • /
    • 2006
  • Flow-able backfill is known as soil-cement slurry, void fill, and controlled low-strength material (CLSM). The benefits of CLSM include reduced equipment costs, faster construction, re-excavation in the future, and the ability to place material in confined spaces such as narrow parts nearly impossible for compaction or perimeter of underground power cables. A review of some recent full-scale tests carried out by KEPRI on slurry backfill materials for application in underground power cable was presented. Based on this research, applicability was assessed and compare to results of laboratory tests for improved slurry materials with optimal mixture contents.

  • PDF

Effect analysis of distributed jointing method on underground Transmission Cables (지중송전케이블의 분산식 접속법에 따른 영향 분석)

  • Ha, C.W.;Kim, J.N.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.148-150
    • /
    • 2002
  • The distributed jointing method is used in the underground tunnel due to narrow space of jointing. This method causes non-uniform length between cable joints. It has an effect on the sheath circulating current and the induced voltage. Furthermore the distributed jointing method may cause transient overvoltage resulting from lightning in underground cable which is connected with overhead line. The author diversely studied the sheath circulating current and induced voltage on underground cable depending on the distributed jointing length under the normal and the transient circumstances. The various simulation results really improve the cable system utility.

  • PDF