• Title/Summary/Keyword: Underground cables

Search Result 244, Processing Time 0.02 seconds

The Characteristic of Laws on the Kind of Urban Green Spaces and the Legal Requirements for the Green Spaces of Urban Habitat in China (중국의 도시녹지 종류와 도시거주구 녹지의 설치 기준에 관한 법제도의 현황과 특성)

  • Shin, Ick-Soon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.1-11
    • /
    • 2013
  • This study investigated Chinese Laws on the kind of urban green spaces and the legal requirements for the green spaces of urban habitat and analyzed the specificities of them intending to provide basic data to suggest bringing in or not the relevant Chinese Laws to Korea. This study can be summarized as follows: First, the concept of Chinese urban green spaces(g.s.) classified by 5 kinds(park g.s., production g.s., protection g.s., attachment g.s., the others g.s.) placed the park and green spaces in the same category unlike the Korean urban green spaces that only distinguishes between park and green spaces. The Chinese Urban Park is classified by 4 kinds(composite park, community park, special park, linear park) at the 'Standard for urban green spaces classification' which is below in rank of the legal system. Second, in case of calculation for green spaces ratio of urban green spaces in China, the green rooftop landscaping area should not be included as a green spaces area except the rooftop of a basement or semi basement building to which residents have easy access. The green spaces requirements and compulsory secure ratio by 3 habitat kinds(habitat, small habit, minimum habitat) of when to act as a residential plan is regulated. Third, the green spaces system is obligated to establish at habitat green spaces plan and is specified to conserve and improve existing trees and green spaces. The green spaces ratio on reconstruction for old habitat is relaxed to be lower than for new habitat and a gradient of green spaces is peculiarly clarified. The details and requirements for establishment and the minimum area intending for each classes of the central green spaces(habitat park, children park, minimum habitat's green spaces) are regulated. Especially at a garden style of minimum habitat's green spaces, intervals between the south and north houses and a compulsory security for green spaces area classifying into two groups(closing type green spaces and open type green spaces) by a middle-rise or high-rise building are clarified. System of calculation for green spaces area is presented at a special regulation. Fourth, a general index(area/person) of public green spaces within habitat to achieve by 3 habitat kinds is determined, in this case, the index on reconstruction for a deterioration zone can be relaxed to be lower to the extent of a specified quantity. A location and scale, minimum width and minimum area per place of public green spaces are regulated. A space plot principle including adjacent to a road, greening area ratio against total area, security of open space and the shadow line boundary of sunshine are also regulated to intend for public green spaces. Fifth, the minimum horizontal distance between the underground cables and the surrounding greening trees are regulated as the considerable items for green spaces when setting up the underground cables. The principle to establish green spaces within public service facilities is regulated according to the kind of service contents. It shall be examined in order to import or not the special regulations that only exist in Chinese Laws but not in Korean Laws. The result of this study will contribute to gain the domestic landscape architect's' sympathy of the research related to Chinese urban green spaces laws requiring immediate attention and will be a good chance to advance into the internationalization of Korean Landscape Architectural Laws.

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

An Experimental Study on the Fire Monitoring System for Tunnel Using SMA and Fiber Optic Cable (형상기억합금과 광케이블을 이용한 터널의 화재감지 시스템 개발에 관한 실험적 연구)

  • Hwang, Ji-Hyun;Park, Ki-Tae;Lee, Kyu-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.128-134
    • /
    • 2014
  • Recently, design and construction of street tunnels tend to focus on cost reduction and preservation of nature. Accordingly, research is actively being carried out to quickly detect fires when they occur in tunnels, which have partially closed structures. Among such research, fire detection methods using optical fiber sensors have a wide bandwidth and fast transmission speed, while using light as a medium. Therefore, it does not receive electrical interference and there is almost no loss of information during transmission, while also having little noise as well. In relation to this, a fire monitoring system that can accurately detect the location of fires in real time using shape memory alloy and optical cables was developed in this study. In order to verify the developed method, light loss measurement test was conducted according to indoor temperature changes, while also conducting fire simulation tests by installing test beds in common underground zones with different external environments of temperature and distance. Upon carrying out experiments, the fire monitoring system developed in this study was found to be able to detect fires in long distance sections in real time.

A Study on the Indirect Benefits of Undergrounding Overhead Power Line Projects in an Urban Area Using Contingent Valuation Method (조건부가치측정법(CVM)을 이용한 도심지 송전선로 지중화사업의 간접편익 추정)

  • Park, Chan-Ho;Kim, Sung-Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.871-879
    • /
    • 2008
  • Recently, as there are a rise in the standard of living and higher concerns of an electromagnetic wave and environment, undergrounding the aerial cables which are supported by large pylons and generally considered as the least attractive feature of an urban area is on an increasing trend to improve aesthetic benefits and electric reliability. This study applied Contingent Valuation Method (CVM) which is expected to become an effective tool to measure indirect benefit to estimate the substantial benefits of undergrounding overhead power line projects in an urban area. The tunneling construction project of the 345kV Shinsungnam electric power cable in Seongnam city was selected and a hypothetical scenario was given to respondents to determine their levels of Willingness to Pay (WTP) for undergrounding overhead power lines. The result from the estimation of the WTP of undergrounding overhead power lines in Seongnam city was calculated as approximately 17.1 billion won. Placing existing overhead lines underground is difficult to justify economically. Most undergrounding costs appear to be justified by aesthetic and public policy considerations. Therefore, considering the result of this study, undergrounding overhead power lines is of great benefit to public.