• 제목/요약/키워드: Underground Sound

검색결과 57건 처리시간 0.028초

지하철 역내 가스 검출 원격 모니터링 시스템 구현 (Development of a remote monitoring system for gas detection at the subway station)

  • 박용만;김희식;김규식;이문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

NATM 터널 설계/시공을 위한 새로운 가이드라인 고찰 (New guideline for geomechanical design/construction of conventional NATM tunnels)

  • 김창용;홍성완;김광염;백승한;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제7권1호
    • /
    • pp.73-88
    • /
    • 2005
  • 본 논문에서는 현재 암반 지하 구조물의 설계에 있어 사용되고 있는 접근법인 정량적 암반분류시스템, 시공중 암반 거동에 근거한 분류시스템 그리고 일반적인 정성적 설계 절차의 특징 및 장단점을 살펴보았으며, 이러한 설계 기법의 단점을 해결하기 위하여 제안된 오스트리아 터널 설계 가이드라인을 소개하고 국내의 경우와 비교하였다. 그 결과 기술적으로 안전하고 경제적인 터널 건설을 위해서는 불확실한 지반조건 및 환경조건에 매우 유연하게 대처할 수 있는 설계 및 시공 기술이 필요하다고 판단되며, 오스트리아 터널 설계 가이드라인에서 이와 관련된 기준을 제시하고 있다. 따라서 국내에서도 안전하고 경제적인 터널 건설을 위하여 시공중 계측 자료를 충분히 활용하여 실제 지반 조건을 예측하고 불확실한 지반 조건에 유연하게 대처할 수 있는 설계 및 시공 기술을 적용하는 것이 바람직하다고 사료된다.

  • PDF

지중 원격 음파통신 시뮬레이션 연구 (A Study on the Simulation of Underground Acoustic Telemetry)

  • 신영기
    • 플랜트 저널
    • /
    • 제18권2호
    • /
    • pp.41-45
    • /
    • 2022
  • 머드 유동 압력파를 이용한 기존의 통신방식은 속도가 1-2 bps 수준으로서 통신에 소요되는 시간이 길어 실시간 제어가 불가능한 수준이다. 통신 속도를 10배 이상 향상시키기 위한 음파통신 방식은 상용화되기는 하였으나 가격이 비싸 이용이 제한적이고 응용 사례도 많지 않다. 본 연구는 해당 설비에 해당하는 시뮬레이터를 개발하여 실제 시험 결과와 유사하게 성능을 개발하였다. 드릴 파이프를 통한 음파 통신 모사를 위해 머드에 의한 마찰 감쇠를 모사할 수 있는 지배 방정식을 제안하고 수치해석 모델을 개발하였다. 감쇠 계수는 시추 현장에서의 음파 에너지 감쇠율과 비교하여 보정하였다. 개발된 수치해석 모델을 대상 QPSK 변조 방식의 통신 알고리즘을 적용하여 지상부에서 통신 에러율 0.04% 수준의 우수한 성능을 확인하였다. 이는 아직 노이즈가 혼입되지 않은 조건에서의 통신 성능이며 이를 적용하기 위해 현장 노이즈 데이터를 확보하여 혼입을 위한 실제 노이즈 신호를 재생하는 기술을 확립하였다.

  • PDF

터널통과 전동차 내외부 소음 특성 규명 (Identification of Noise Characteristics for Subway Train Passing through the Underground Tunnel)

  • 조준호;이규진;정우성;홍철기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.340-345
    • /
    • 2002
  • Passengers in automobile or train are exposed to a worse noise environment when they are in the tunnel than in the open field. This is due to a relatively higher space density of sound energy by multiple reflection phenomenon of noise generated by operation of transportation vehicles from tunnel wall compared to open field. In this study, noise characteristics of subway train running through a tunnel were investigated at straight/curved track and tunnel type(semi circular/box). Also the noise measured simultaneously at inner and outer sides of train running through a tunnel, so that the coherence of the various noise sources of subway train to inner noise was evaluated.

  • PDF

토양 및 지하수 보전을 위한 토양관리 및 대책방안 (Management Strategy for Soil and Groundwater Conservation)

  • 김경숙;정재춘
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.221-224
    • /
    • 1998
  • Environmental pollution is continuously increasing with the economic growth and industrial development. With this trend, soil and groundwater pollution problem has been surfaced as important social issues. Recently, Korean government promulgated the Soil Environment Conservation Act. But there are many problems to control sound soil quality management. Anthropogenic source of pollution such as waste landfill, pesticides, fertilizer, underground storage oil tanks is important as well as natural source such as acid rain and forest fire. The regulation should be expanded to include groundwater preservation as well as soil quality, because soil pollution is closely related to groundwater pollution. Therefore, legal regulations must be expanded to these facilities and take into account technical feasibility and finance.

  • PDF

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

지하투과레이다 기법을 이용한 부안 수성당 지역의 지하 유적 탐사 (Detection of Subsurface Ancient Remains in Sooseong Dang Area, Buan Using Ground Penetration Radar Technique)

  • 이현재;전항탁;윤설민;함세영
    • 지질공학
    • /
    • 제29권4호
    • /
    • pp.553-563
    • /
    • 2019
  • 고고학적 유적지 탐사의 최종 단계에서는 시굴과 발굴조사를 실시하지만, 초기 단계에는 비파괴방법인 지구물리탐사를 이용하여 지하의 유적지를 평가한다. 그 중에서도 GPR 탐사는 천부 지하에 대한 해상도가 높아 유적지 조사에 효과적으로 적용되어 왔다. 본 연구에서는 부안지역의 수성당 부근 지하에 매장되어 있는 유물을 찾기 위해서 지하투과레이다(Ground Penetration Radar, GPR) 탐사를 실시하였다. 1차 GPR 탐사는 세 개 지역(Site-1, 2, 3)에서 수행하였고, 1차 조사의 결과를 바탕으로 2차 세부 GPR탐사는 Site-3에서 수행하였다. 탐사 결과, 지표로부터 표토층, 풍화대, 기반암이 나타나는 것으로 파악되었으며, 뚜렷한 이상대는 심도 약 100 cm 내외에서 장축 방향의 측선과 평행한 동서에 가까운 방향성을 나타내고 있다. 이 GPR 이상대의 불규칙한 형태적 특징과 강신호의 단속적 분포 양상은 수성당에서 발견된 제사도구와 연관이 있을 것으로 판단된다. 이러한 GPR 탐사는 지하 천부에 매장되어 있는 고고학적 유적이나 유물을 탐지하는데 효과적으로 이용될 수 있을 것으로 판단된다.

홍도의 소리경관 자원의 발굴, 보존 및 육성을 위한 사운드스케이프 조사연구 (Research on the Soundscape for Excavation, Preservation and Promotion of Soundscape Resources in Hongdo Island)

  • 한명호;오양기;노태학
    • 한국음향학회지
    • /
    • 제28권4호
    • /
    • pp.343-355
    • /
    • 2009
  • 이 연구는 지역의 소리환경의 정체성을 회복하고 소리문화로 계승/발전시키기 위하여, 그 지역의 소리경관 자원을 발굴하여 보존하고 육성하기 위한 방안을 마련하기 위한 조사연구이다. 이러한 목표를 위해, 이 연구는 한국의 서남해안의 섬인 홍도를 대상으로 주민의 면담조사와 소리들으며 걷기를 이용한 관찰조사를 수행하였다. 조사결과, 홍도에서 들을 수 있는 소리는 새소리, 파도소리, 바람소리, 갈매기소리, 몽돌구르는 소리 등의 자연의 소리, 그리고 뱃고동소리, 선박의 안내방송, 관광객들의 말소리, 교회의 종소리, 등대의 에어사이렌 등의 인공의 소리에 이르는 많은 소리가 있는 것으로 확인되었다. 또한 연구의 결과, 홍도의 고유한 사운드스케이프를 회복하기 위해서는 몇가지 방안을 배려할 필요가 있는 것으로 조사되었다. 즉, 선박 안내방송의 효율적 운영개선, 몽돌해수욕장의 선착장 이전, 당산제 행사의 운영 및 관리, 홍도 등대 및 무종의 보존 및 관리, 마을 복개하천의 복원 및 정비, 마을 공동어시장의 운영 및 관리, 풍어제 및 홍어축제의 복원, 홍도운동회의 운영관리, 뱃고동소리의 음질 변경, 상여소리 등의 민속문화자원의 복원, 생태자연환경 및 도서해양환경의 보존활동, 지역의 활력과 매력을 위한 어메니티 증대를 꾀하는 방안이 필요한 것으로 파악되었다. 또한 많은 관광객들이 이러한 홍도의 사운드스케이프의 정체성과 소리환경의 중요성을 깨닫고 홍도의 사운드스케이프를 직접 체험하고 느낄 수 있도록 하기 위한 소리지도 (Sound Map)를 작성하였다.

음향방출 및 가속도 신호를 이용한 지하매설 상수도배관의 누수지점 탐지연구 (Leak Location Detection of Underground Water Pipes using Acoustic Emission and Acceleration Signals)

  • 이영섭;윤동진;정중채
    • 비파괴검사학회지
    • /
    • 제23권3호
    • /
    • pp.227-236
    • /
    • 2003
  • 지하매설 상수도 배관의 누수는 사회적, 환경적 그리고 경제적 문제를 야기시킨다. 이러한 누수에 대한 적절한 대응책의 하나로서 배관의 누수지점에 대한 탐지 및 수리가 해당될 것이다. 누수음은 배관의 누수지점의 식별에 좋은 탐지원이다. 비록 청음봉, 청음기 또는 지상마이크로폰과 같은 누수음으로 누수지점을 탐지하는 몇 가지의 방법이 있어 왔지만, 과들은 이렇게 효율적인 도구들은 아니었다. 본 논문에서는, 좀 더 쉽고 효율적인 방법을 제공할 수도 있는 음향방출센서와 가속도계를 사용한 누수위치탐지를 다룬다. 누수지점 탐지를 위해 센서로부터의 입력신호에 대한 필터링, 신호처리 및 알고리듬을 기술하였다. 120 미터 길이의 배관이 실험을 위해 설치가 되었고, 실험결과들은 음향방출센서와 가속도계가 누수지점의 정밀탐지에 이용될 수 있음을 보여 주었다. 누수지점의 탐지에 극히 중요한 지하매설배관 속의 유체의 음파 전파속도에 관한 이론적 해석 또한 기술되었다.

넌코히어런트 전송 방식에서 초음파를 이용한 디지털 통신속도 개선 프로토콜 제안 (Proposal of a non-coherent Communication Protocol with Ultra Sonic which can Improve the Communication Speed)

  • 윤병우
    • 융합신호처리학회논문지
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2009
  • 수중이나 지하에서는 매질의 전도성으로 인하여 전파를 이용한 무선 통신이 어렵다. 이러한 경우 초음파 등과 같은 음향신호를 이용하여 무선통신을 하는데 이 경우도 시변 다경로현상, 도플러효과, 각종 감쇄 등으로 인하여 코히어런트방식의 통신에서는 장거리 전송이 어렵다. 따라서 장거리 전송에서는 FSK 등과 같은 넌코히어런트방식의 데이터 전송방식을 사용하는데 이 경우 음향신호의 전송속도가 늦다는 특성 때문에 넓은 대역폭의 데이터 전송이 어렵다. 수중에서 다양한 통신 수요에 따라 음성통신 뿐만 아니라 화상 데이터 전송 등이 요구되는데 이와 같은 많은 데이터 전송시 넌코히어런트방식의 통신에서 그 요구조건을 만족시키기가 어렵다. 본 연구에서는 시간지연신호에 디지털 데이터를 실음으로써 동시에 8비트 또는 16비트 등과 같이 여러 비트의 데이터를 전송함으로써 전송속도를 개선할 수 있는 새로운 전송프로토콜을 제안한다.

  • PDF