• Title/Summary/Keyword: Underground Safety

Search Result 1,126, Processing Time 0.024 seconds

Method to Improve the Location Accuracy of GPR Data for Underground Information Precise Detecting (지하정보 정밀탐사를 위한 GPR 데이터 위치정확도 개선 방안)

  • RYU, Jisong;JANG, Yonggu;PARK, Donghyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.3
    • /
    • pp.32-40
    • /
    • 2021
  • Underground information is difficult to visually check, which can lead to a huge accident in the event of a safety accident. Recently, the Ministry of Land, Infrastructure and Transport intends to reduce safety accidents caused by the aging or damage of underground facilities through the Special Act on Underground Safety Management. GPR is increasingly being used as a technology to acquire information in underground spaces that are difficult to see with the naked eye. However, GPR's location information is corrected by checking images of CCTV and GPS information acquired during exploration. This method has an average error of about 2 meters. In this works, We used LiDAR to calibrate the GPR information and found that the error was reduced from at least 7cm to up to 40cm. If accurate GPR information collected in the future is analyzed quickly using AI, etc., it will be able to collect and utilize underground information faster than it is now to secure safety.

Study on Improvement Plan of System through Analysis of Ground Sink Accidents - Focused on the management of underground facilities and their surrounding ground - (지반함몰 사고 분석을 통한 제도 개선안 연구 - 지하시설물 및 주변지반 관리 중심으로 -)

  • Kim, Dong-jin;Lee, Jong-keun;Kim, Hong-kyoon;No, Tae-kil
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.3 no.1
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to propose a system improvement plan to prevent ground sinking accidents. To do this, follow the procedure below. First, it defines terms that are used interchangeably, such as ground subsidence and ground depression. Second, analysis of the current status and cause of ground sink, and the analysis of the correlation between rainfall and ground sink causes, derives priority management causes. Third, we propose a system improvement plan for the cause of priority management. As a result, damage to underground pipes and inadequate underground works were identified as the cause of priority management, and two system improvement plans to manage them were proposed. The results of this study can be used as basic data for improving the system for more effective prevention of underground sink in the future.

A Study on the improvement of working condition in the downtown Underground construction - Focused on the Ventilation and Lighting - (지하건설공사의 작업환경 개선에 관한 연구 -환기와 조명을 중심으로-)

  • 고성석;안홍섭
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.119-132
    • /
    • 1997
  • According to the construction environmental changes due to the trend of large scale and complicated building construction, many construction methods(such as : TOPDOWN )are more often used. However, it is pointed out that occupational pulmonary diseases, reduction of the machinery lifetime and productivity caused to be narrow visual field and collision between the workers. Therefore, this study is mainly dealing with the views of productivity and safety improvement in order to improve work efficiency and to insure the safety in underground construction environment.

  • PDF

Study on the Ways to Improve Deep Underground Road Facilities and Operation Based on the Cases of Longitudinal Tunnel (장대터널의 사례에 기반한 대심도 지하도로 교통시설 및 운영 개선방안)

  • Choi, Jong Chul;Lim, Joon Beom;Hong, Ji yeon;Lee, Sung Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.122-131
    • /
    • 2015
  • Recently, starting with the deep underground road construction plan in Seobu Expressway, Korea, there area many studies on deep underground roads to be newly built. However, there is an extreme lack of safety standards, which does not consider traffic conditions and road driving characteristics. Therefore, this study reviewed safety elements to reflect in the deep underground road planning by analyzing driving stability of longitudinal tunnels with road environments, which resemble deep underground roads. For comprehensive analysis, the characteristics and causes of the accidents that have occurred in seven longitudinal tunnels with a length of 2km or over in Gangwon area, were collected. Specifically, geometric structures and facilities of each tunnel were investigated. Also, the present state of facility installation and the changes in driving speed of vehicles passing through each tunnel were observed to analyze the causes for the traffic accidents in each tunnel and accident reduction alternatives. It was revealed that the most frequent accidents in the tunnels resulted from the changes of traffic flow due to the abrupt speed reduction of forward vehicles, or the failure in speed control of following vehicles during the traffic congestion situation. Moreover, installing facilities such as plane and longitudinal curves, median strips and marginal strips seem to induce consistent driving speed. These results mean that for accident prevention, speed management must be preceded and there is a need to develop and introduce safety facilities actively to control the driving flow of forward and following vehicles.

A Study on the Optimized Installation of Gas Storage Tank through Pugh Method (퓨 방법을 통한 최적의 저장탱크 시공에 관한 연구)

  • Huh, Yong Jeong;Lee, Jong Rark;Lee, Seon Yeong;Leem, Sa Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.8-12
    • /
    • 2014
  • The aim of this study is achieving customer satisfaction by finding cost-effective installation of storage tanks in the gas filling stations. Pros and cons were measured by comparison between above and underground tanks using Pugh methods. In particular, severe problems regarding gas safety are expected to be resolved by reducing the frequency of gas accidents occurred in mass storage facilities. To this end, we have used Pugh's method to compare the advantages and disadvantages of the existing storage tanks-Ground above type and underground type. After the analyses, it is shown that underground containment storage tank can provide the highest degree of safety and Real estate among Ground above type, Underground buried type and underground containment type storage tanks.

Analysis of Electromagnetic Field Around Distribution Line (배전선로 주변에서의 전자계 분포 해석)

  • Kwon, Myung-Rak
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.672-676
    • /
    • 2017
  • Electrical energy is playing an increasingly vital role as the primary energy source in everyday life. With the increase in electric power consumption, power facilities are under an increasing stress and must operate at a high capacity. Consequently, the demand for electric power cables in power transmission and distribution lines is rapidly increasing. Underground distribution lines have been steadily replacing the aboveground lines owing to the increase in electric power demand and the need to increase the supply voltage. In addition to line damage, worker safety is of primary concern in this type of underground infrastructure. In this study, to improve the safety of workers dealing with underground transmission lines, we analyzed the electromagnetic field generated around the distribution line and determined the basic criteria for developing a device that can detect a live underground line.

An Investigation Into the Actual Condition of Electrical Equipments Installation and Management for Establishing the Countermeasures Against the Electric Shock in Submerged Underground (지하구내 침수시 감전 방지대책 수립을 위한 전기설비 설치 및 관리실태 조사)

  • Jung, Jin-Soo;Jung, Jong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.84-90
    • /
    • 2008
  • This paper describes the investigation into the actual condition of electrical equipments installation and management for establishing the countermeasures against the electric shock in submerged underground. The investigation was carried out for 27 underground premises in conurbation including Seoul, and potential of the exposed electrical equipments negatively affecting on human safety when disaster occurs was measured. The objects to which measurement was carried out were as follows; electrical source; advertising lighting; power equipment. As a result, it was confirmed that potentials more than 230[V] were induced in some equipments. In addition, the electrical equipments installed in most conventional underground premises were left unmanaged.

The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point (지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정)

  • Kim, Jae-Hyun;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5123-5127
    • /
    • 2011
  • Research and development for the technology, that is about maintenance and accidents prevention of underground power distribution line, are demanding. The precise detection of leakage point of underground power line is very important, because it is difficult to detect the exact location of a fault in underground power line and to repair faults. When earth electric potential is measured to detect underground electric leakage point after transmitting AC electric pulse wave to underground power line, it must be measured in a specific half period of AC pulse wave because the distribution of the electric earth potential varies with the polarity of the transmitted wave. In this paper we proposed the measurement of half period modulated earth potential as a method to detect a underground leakage point. And We compared the proposed method with other methods. Through experiments we verified that the proposed method can be implemented and operated properly.

Electrical Risk Factors affecting Human Body due to Underground Flooding (지하구내 침수 시 인체에 대한 전기적 위험요소 도출)

  • Jung, J.W.;Lim, Y.B.;Jung, J.S.;Ko, W.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.56-59
    • /
    • 2005
  • In this paper, electrical risk factors due to the powered recovery equipments thrown to escape the dangerous condition that electrical apparatuses were submerged were derived and analyzed. After surveying several underground flooding sites, we could find out the status quo of the underground electrical equipments and what the most dangerous factors to a human body under water were. The results acquired from this study are applying to safely assessment algorithm.

  • PDF

Strength Method Using Pre-flexed Members for the Corner of Underground Box Structures under Additional Surface Load (추가 상재하중을 받는 지중박스구조물의 우각부에 대한 프리플렉스 부재를 이용한 보강공법)

  • Chung, Jee Seung;Lee, Jin Hyuk;Kim, Ki Am
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.102-108
    • /
    • 2016
  • This paper presents a new strength method of underground box structures under additional surface load. An L-bracing using pre-flexed steel member threads called the "Pre-flex strength method" is used to improve capacity of the RC box structure under earth pressure due to additional surface load. The pre-flexed steel member is fixed the top and bottom of the structure after chemical anchor was installed by drilling hole on the box structure. The structural performance was evaluated analytically. 3 types of underground RC box structure were used; $2.0m{\times}2.0m$, $3.0m{\times}3.0m$ and $4.0m{\times}4.0m$. For the performance evaluation, structure analysis were performed on moment and shear resisting structures with and without pre-flex strength method. Numerical results confirmed that the proposed strength member system installed on underground RC box structures enhanced the strength capacity. The feasible region of the proposed pre-flex strength method in accordance with the earth pressure due to additional surface depth was evaluated.