DOI QR코드

DOI QR Code

Strength Method Using Pre-flexed Members for the Corner of Underground Box Structures under Additional Surface Load

추가 상재하중을 받는 지중박스구조물의 우각부에 대한 프리플렉스 부재를 이용한 보강공법

  • Received : 2016.07.29
  • Accepted : 2016.10.24
  • Published : 2016.10.31

Abstract

This paper presents a new strength method of underground box structures under additional surface load. An L-bracing using pre-flexed steel member threads called the "Pre-flex strength method" is used to improve capacity of the RC box structure under earth pressure due to additional surface load. The pre-flexed steel member is fixed the top and bottom of the structure after chemical anchor was installed by drilling hole on the box structure. The structural performance was evaluated analytically. 3 types of underground RC box structure were used; $2.0m{\times}2.0m$, $3.0m{\times}3.0m$ and $4.0m{\times}4.0m$. For the performance evaluation, structure analysis were performed on moment and shear resisting structures with and without pre-flex strength method. Numerical results confirmed that the proposed strength member system installed on underground RC box structures enhanced the strength capacity. The feasible region of the proposed pre-flex strength method in accordance with the earth pressure due to additional surface depth was evaluated.

Keywords

References

  1. J.S.Chung, J.G.Kim and J.H.Lee, "The Earthquake Resistant Reinforcement Method of the Existing R.C Box Structures suing Pre-flexed Member System", Journal of the Korean Society of Safety, Vol. 31, No. 3, pp.68-74, 2016. https://doi.org/10.14346/JKOSOS.2016.31.3.68
  2. D. H. Min, C. Park, Y. S.Yoon, D. K. Park and K. A. Kim, "Development of Strengthening Method for RC Box Structures Using Pressure Members", KSCE Conference, pp.141-144, 2012.
  3. J. S. Chung, Y. K. Kang, B. H. Kim, D. H. Min, Y. S. Yoon and J. W. Jeong,"A Study on the Arrangement of pressure Menbers for Strengthening in the RC Box Structure", KSCE Conference, pp.2396-2399, 2012.
  4. D. H. Min, C. J. Cha, Y. S. Yoon, D. K. Kim and D. Kim "Development of Corner Joint Strengthening Method for RC Underground Box Structures using Pressure Members", Korea Institute for Structural Maintenance and Inspection' autumn conference, pp409-410. 2014.
  5. J.S.Chung, I.G.Moon, D.H.Min, "Anti-seismic Capacity imporovement of Underground Box Structures Strengthened with Pressure Bracing", Journal of the Korean Society of Safety Vlo. 28. No.4, pp.97-102, 2013. https://doi.org/10.14346/JKOSOS.2013.28.4.097
  6. Ministry of Land, Transport and maritime Affairs, "Concrete Structure Code", 2012.
  7. D. H. Min, J. S. Kong, J. S. Chung. Y. S. Yoon and D. G. Kim "Strenghening Method using Pre-flexed Members for the Corner Reinforced Concrete Box Structures under Ground", Korea Institute for Structural Maintenance and Inspection' Spring Conference, pp.365-366, 2015.
  8. Ministry of Land, Transport and maritime Affairs, "Common Duct Design Criteria", 2010.
  9. S. G. Song "A Study on Strengthening Method for the Corner of box Structures using Pre-flexed Members", Korea University, 2016.