• Title/Summary/Keyword: Underground Road

Search Result 341, Processing Time 0.022 seconds

A Design Focuses on the Internal Structure of Double-level Tunnel (도심지 대심도 복층터널의 내부구조물 계획)

  • Park, Shin-Young;Jeong, Jae-Ho;Cho, Nam-Kak;Shin, Il-Jae;Sim, Dong-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1314-1321
    • /
    • 2010
  • The west express way which links south west area of the central city of Seoul has been notorious for extremely heavy traffics since its first opening in 1991(i.e. the average vehicle speed is less than 25km/h, a daily traffic is 112,000 and among them, more than 94% of the vehicles are the light vehicles). The city government recently initiated a new BTO(Build-Transfer-Operate) project as an alternative in releasing heavy traffic and a high construction cost. The proposed underground express road is the first double-level tunnel (i.e. a total length of road is 10,91km and the tunnel is 9.308km long) ever built in South Korea, while such tunnel system is not new worldwide as such A86 East tunnel in France, SMART tunnel in Malaysia, and Fuxing tunnel in China. This paper discusses major design issues regarding the internal structures such as deck slab, and secondary liner.

  • PDF

A Study for Construction of Road and Underground Facilities Information Sharing Systems in Local Government (지자체단위의 도로기반시설물 정보공유체계 구축을 위한 연구)

  • 김명호;신동빈;안종욱;김감래
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.4
    • /
    • pp.347-357
    • /
    • 2002
  • It is required that information sharing and integrated management between roads and underground facilities because there are so many possibilities to happen unexpected accidents. But if there are road excavation work happened, work agency should ask fer other facility information to the facility management company. In the case of local government, it is increasing that the needs for the development of roads and underground facilities management system and information sharing because digital map generation(1/1,000 scale) completed. In this study, as a way of integrated management and information sharing between roads and underground facilities, centralized system based on internet web technique and decentralized system based on closed network technique between the local government are considered. And for the development of information sharing system, action plan and considering points are proposed.

A Study on Facility Information System using GIS and Semantic Web in Underground Space

  • Cui, Yulan;Hwang, Hyun-Suk;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.12
    • /
    • pp.1843-1854
    • /
    • 2010
  • The utilization of underground space has recently increased with the complication of road, the rise of the land price, and the development of green technology. Underground space ranges from classical excavations to subway, underground cities, and shopping malls where there are crowds of people. At this time, government has spent a lot of money in installing various types of safety facilities for preparations of increasing potential disasters. Therefore, an effective facility management system is required. In this paper, we propose an information retrieval process to effectively extract the facilities' information based on the ontology and spatial analysis in underground space. The ontology-based searching supports hierarchical and associated results as well as knowledge sharing with hierarchy concepts. The spatial analysis based searching has "Buffer" and "Near" functions to operate on a map without understanding any property of the facility information.

Evaluation of seismic performance of road tunnels in operation (운영 중인 도로 터널의 내진 성능 평가)

  • Ahn, Jae-Kwang;Park, Du-Hee;Kim, Dong-Kyu;Kim, Kwang-Yeom
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.69-80
    • /
    • 2013
  • This study evaluates the seismic performance of road tunnels designed before the provisions for seismic design of tunnels were first established in 1999. Extensive design data and site investigation reports are investigated to select tunnels sections that are considered to be most susceptible to seismically induced damage under earthquake loading. Detailed analyses are performed on selected tunnels. The methods used are method of displacement and dynamic analysis. In performing the method of displacement, which is a type of pseudo-static analysis method used for underground structures, full domain and reduced domain modeling were used. The dynamic analyses are performed using finite difference method and using nonlinear constitutive model. Comparisons show that the reduced domain method of displacement match very closely with the dynamic analysis, demonstrating that it is the most suitable method for evaluating the seismic performance of road tunnels built in rocks. It is also shown that road tunnels, for which seismic design were not applied, are safe under the seismic risks corresponding to an earthquake with a return period 1000 years. It is concluded that additional seismic retrofit of tunnels is not necessary.

Analysis of Influencing Factors on Cavity Collapse and Evaluation of the Existing Cavity Management System (공동 붕괴를 유발하는 영향인자 분석 및 기존 공동관리 시스템 평가)

  • Lee, Kicheol;Park, Jongho;Choi, Byeong-Hyun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.45-54
    • /
    • 2018
  • In this study, numerical analysis is performed to determine highly influential factors that increase the possibility of asphalt road collapse due to cavity underneath the road. The considered influence factors on road collapse due to underground cavity were the asphalt layer thickness, the cover depth, the cavity width, and the cavity height. The concentrated load and uniform distributed pressure were applied on the top surface of asphalt pavement layers with different shape of cavity and asphalt thickness. For each analysis case of given cavity and asphalt thickness, failure load was analyzed under displacement controlled condition. Based on the analyzed failure loads, the applicability of the cavity management system developed by Seoul city was evaluated. As a result of the analysis, the effect of cavity height on road collapse was not significant while the other factors considerably influenced road collapse. Consequently, degree of road collapse susceptibility should be classified by failure load rather than by the condition of existing cavity.

Rock fall on tunnel portals

  • OGGERI, Claudio;PEILA, Daniele;PELIZZA, Sebastiano;KIM, Sanghwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.357-365
    • /
    • 2004
  • Tunnel portals are often located in areas where the risk of rock fall and/or detachement of rock fragments from rocky slopes is high. In this case it is necessary to design the portals so as to protect the road (i.e. using an artificial tunnel) or to instal structures that are able to intercept falling blocks on the slope. This paper deals with the design problems of these structures and includes a special analysis of net fences which have undergone a remarkable technological improvement over recent years.

  • PDF

Development and Evaluation of the Road Energy Harvester According to Piezoelectric Cantilever Structure and Vehicle Load Transfer Mechanism (압전 캔틸레버 구조와 차량하중 전달방법에 따른 도로용 에너지 하베스터의 설계 및 평가)

  • Kim, Chang-Il;Kim, Kyung-Bum;Jeong, Young-Hun;Lee, Young-Jin;Cho, Jeong-Ho;Paik, Jong-Hoo;Kang, In-Seok;Lee, Moo-Yong;Choi, Beom-Jin;Park, Shin-Seo;Cho, Young-Bong;Nahm, Sahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.773-778
    • /
    • 2012
  • A road energy harvester was designed and fabricated to convert mechanical energy from the vehicle load to electrical energy. The road energy harvester is composed of 16 piezoelectric cantilevers. We fabricated prototypes using a vehicle load transfer mechanism. Applying a vehicle load transfer mechanism rather than directly installing energy harvesters under roads decreases the area of road construction and allows more energy harvesters to be installed on the side of the road. The power generation amount with respect to the vehicular velocity change was assessed by installing the vehicle load transfer mechanism form and underground form. The energy harvester installed in the underground form generated power of 4.52 mJ at the vehicular velocity of 50 km/h. Also, power generation of the energy harvester installed in the vehicle load transfer mechanism form was 48.65 mJ at the vehicular velocity of 50 km/h.

Air Pollutant Emission Characteristics of a Light Duty Diesel Vehicle Affected by Road Infrastructure Improvement and Traffic flow Changes (도로 기반시설 개선과 교통흐름 변화에 따른 소형 경유자동차의 대기오염물질 배출특성)

  • keel, Jihoon;Lee, Taewoo;Lee, Sangeun;Jung, Sungwoon;Yun, Boseop;Kim, Jeongsoo;Choi, Kwangho
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.214-222
    • /
    • 2016
  • Changes in road infrastructure affect driving patterns and pollutant emission characteristics. we analyzed the changes in driving patterns and pollutant emission characteristics of the driving route via measured driving patterns at year 2009 and 2016. Since 2009, there has been an increase in population and traffic demand, including residential areas and industrial facilities. Traffic conditions were improved such as the opening of the highway Inter-Change to Seoul and the construction of underground driveway. As a result, the average vehicle speed increased. More detail comparisons have made on the changes of the underground driveway section and the crossroad section, which are expected to have significant changes in the transportation infrastructure. The vehicle speed distribution of the underground driveway changed from low speed to high speed, and the increase of the time spent at the high speed and high load caused the increase of NOx emissions. The vehicle speed also increased at the crossroad section, and the consequence NOx and $CO_2$ emissions decreased. It is mainly because the decreased time spent at idle, which results from the proper traffic demand management at this area.

Calculation of a Diesel Vehicle's Carbon Dioxide Emissions during Haulage Operations in an Underground Mine using GIS (GIS를 이용한 지하광산 디젤 차량의 운반작업 시 탄소배출량 산정)

  • Park, Boyoung;Park, Sebeom;Choi, Yosoon;Park, Han-Su
    • Tunnel and Underground Space
    • /
    • v.25 no.4
    • /
    • pp.373-382
    • /
    • 2015
  • This study presents a method to calculate carbon dioxide emissions of diesel vehicles operated in an underground mine using Geographic Information Systems (GIS). An underground limestone mine in Korea was selected as the study area. A GIS database was constructed to represent the haulage roads as a 3D vector network. The speed of dump trucks at each haulage road was investigated to determine the carbon dioxide emission factor. The amount of carbon dioxide emissions related to the truck's haulage work could be calculated by considering the carbon dioxide emission factor at each haulage road and the haulage distance determined by GIS-based optimal route analysis. Because diesel vehicles are widely utilized in the mining industry, the method proposed in this study can be used and further improved to calculate the amount of carbon dioxide emissions in mining sites.

A study on practical use of remote automatic fire extinguishing equipment through test bed in road tunnel (도로터널용 원격 자동소화 설비의 test bed 적용을 통한 실용화 방안 연구)

  • Park, Sang-Heon;An, Sung-Joo;Kim, Jae-Hoon;Kim, Kyung-soo;Yun, Jun-Su;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.837-847
    • /
    • 2019
  • Korea's long underground roads are being promoted around the metropolitan city center to realize advanced transportation networks. Many disaster prevention facilities are applied to secure fire safety of the closed and long-distance underground roads. As the facility response and fire suppression subjects are unclear, additional human and material damages from fire spread are inevitable. Therefore, in this study, we developed a remote automatic fire extinguishing system that uses the fire extinguishing water inside the fire hydrant to monitor the CCTV in the management room and sprays it directly to the fire site through automatic control. The design application method was studied through the performance improvement that can be put into practical use.