• 제목/요약/키워드: Underground Pipe

검색결과 360건 처리시간 0.022초

맨홀과 연결된 지하 열수송설비의 부식 원인 및 재질 내식성 평가 (Cause of Corrosion and Evaluation of Material Corrosion Resistance on Underground Heat Transport Facilities Connected to Manhole)

  • 송민지;최가현;김우철;이수열
    • 열처리공학회지
    • /
    • 제35권4호
    • /
    • pp.193-202
    • /
    • 2022
  • Manholes and underground spaces are installed to manage the buried heat transport pipes of the district heating system, and the corrosion damage of the equipment placed in this space often occurs. The purpose of this work is to identify locations with a high risk of corrosion damage in the air vent and to establish preventive measures based on precise analysis via sampling of heat transport pipes and air vents that have been used for about 30 years. The residual thickness of the air vent decreased significantly by reaching ~1.1 mm in thickness, and locations of 60~70 mm away from a transport pipe were the most vulnerable to corrosion. The energy dispersive X-ray spectroscopy (EDS) analysis was performed in the corroded oxides, and it was found that chloride ion was contained in the corrosion products. Anodic polarization tests were carried out on the air vent materials (SPPS250, SS304) with varying the amounts of chloride ions at two different temperatures (RT, 80℃). The higher concentration of chloride ions and temperature are, the lower corrosion resistances of both alloys are.

Numerical simulation of the flow in pipes with numerical models

  • Gao, Hongjie;Li, Xinyu;Nezhad, Abdolreza Hooshmandi;Behshad, Amir
    • Structural Engineering and Mechanics
    • /
    • 제81권4호
    • /
    • pp.523-527
    • /
    • 2022
  • The objective of this study is to simulate the flow in pipes with various boundary conditions. Free-pressure fluid model, is used in the pipe based on Navier-Stokes equation. The models are solved by using the numerical method. A problem called "stability of pipes" is used in order to compare frequency and critical fluid velocity. When the initial conditions of problem satisfied the instability conditions, the free-pressure model could accurately predict discontinuities in the solution field. Employing nonlinear strains-displacements, stress-strain energy method the governing equations were derived using Hamilton's principal. Differential quadrature method (DQM) is used for obtaining the frequency and critical fluid velocity. The results of this paper are analyzed by hyperbolic numerical method. Results show that the level of numerical diffusion in the solution field and the range of well-posedness are two important criteria for selecting the two-fluid models. The solutions for predicting the flow variables is approximately equal to the two-pressure model 2. Therefore, the predicted pressure changes profile in the two-pressure model is more consistent with actual physics. Therefore, in numerical modeling of gas-liquid two-phase flows in the vertical pipe, the present model can be applied.

수치해석 및 계측자료 분석을 통한 막장볼트의 보강효과에 관한 연구 (A comparative analysis of prediction and measurement for reinforcement effect of face bolts)

  • 서경원;김웅구;백기현;김진웅
    • 한국터널지하공간학회 논문집
    • /
    • 제12권5호
    • /
    • pp.359-368
    • /
    • 2010
  • 국내의 경우 터널 지반보강증 강관다단그라우팅 공법이 폭넓게 시용되지만 해외의 경우 시공성 및 경제성이 막장볼트 공법이 흔히 적용되고 있다. 본 논문에서는 국내 도로터널 붕락 발생시 적용한 강관다단그라우팅 및 막장볼트의 적용효과에 대해서 수치해석을 통해 분석해 보았다. 또한 해외 시공사례의 계측데이터를 바탕으로 두 공법의 보강효과에 대해 분석해 보았다. 본 연구를 통해 막장 전면에 파쇄대가 발달하는 경우 페이스공법도 막장보강에 효과적임을 알 수 있었다.

프리스트레스 및 강관보강 그라우팅을 이용한 터널 필라부 보강공법의 적용성 검토를 위한 축소모형 실험 (Reduced model experiment to review applicability of tunnel pillar reinforcement method using prestress and steel pipe reinforcement grouting)

  • 김연덕;이수진;이평우;윤홍수;김상환
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.495-512
    • /
    • 2022
  • 본 연구에서는 프리스트레스와 그라우팅을 이용한 터널 필라부 보강공법에 대해 검토하였다. 병설터널의 문제점을 보완할 수 있는 보강법들은 다양하지만 프리스트레스와 그라우팅을 이용한 터널 필라부 공법이 현장적용성, 안정성, 경제성에서 우수하다고 판단됨에 따라 실질적인 거동 메커니즘의 이론적 검토 및 수치해석적 검토가 필요하기 때문에 축소모형 실험을 진행하였다. 축소모형 실험은 PC강연선 + 강관보강 그라우팅 + 프리스트레스(Case 1), PC강연선 + 강관보강 그라우팅(Case 2), 무보강(Case 3)으로 나누어 필라부의 변위와 벽체에 가해지는 토압을 측정하였다. 실험을 통하여 여러 공법 중 PC강연선 + 강관보강 그라우팅 + 프리스트레스 공법은 가장 우수한 보강공법임을 확인하였고 추후 현장실험을 통해 이를 검증하고 보완해 나간다면 현재 적용되는 보강공법보다 변위 제어 및 부재력 측면에서 우수한 결과를 도출해 낼 수 있을 것이라 판단되었다.

도시철도 친환경 지하터널 배수형식의 효율적인 유지관리 방안 검토 (A study on efficient management of the drainages of underground tunnels for environmentally friendly urban railway systems)

  • 백종명;홍종헌;김한배
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1982-1990
    • /
    • 2010
  • 서울지하철 1~4호선 구간에서 부분적으로 도시터널공법을 채택하여 건설한 노선은 2~4호선으로서, 2호선 구간은 2기 지하철 건설시 시공된 신정기지 인입선 도림천~까치산역 구간 터널을 제외하고는 전체가 재래식 공법(ASSM)을 3~4호선 터널은 지형적인 여건 및 토압의 영향에 따라서 ASSM공법과 NATM공법을 병행하여 건설하였으며, 지하수 처리 형식은 지반조건과 지형적인 조건, 지하수위 저하에 의한 영향, 장기적인 운전 유지비 등을 감안하여 배수 및 비배수 형식을 적용하여야 하나, 이에 대한 충분한 사전검토 없이 채택하므로서 완전방수(비배수) 형식은 건설시에도 시공성이 떨어지고 기술적으로도 불합리한 요소를 지닌 채 설치되었으며, 부분방수(배수)형식은 배수관 기능저하, 배수구배 부적정 등으로 인해서 터널 구조물의 유지관리에서 누수와 수압에 의한 라이닝 콘크리트 균열, 박리 현상이 지속적으로 발생하여 보수 및 보강공사에 많은 비용이 소요되고 또한 터널 안정성 확보에 어려움이 있는 실정이다. 그러므로 터널 방수 형식에 대한 설계 및 시공 개념을 고찰함으로서 기술적인 문제점 등을 파악해서 유지관리의 개선 방향을 제안하고자 한다.

  • PDF

2차원 관로형 지하시설물 정보 품질검증기술 개발 (Development of 2D Data Quality Validation Techniques for Pipe-type Underground Facilities)

  • 배상근;김상민;유은진;임거배;정다운
    • 산업경영시스템학회지
    • /
    • 제46권3호
    • /
    • pp.285-292
    • /
    • 2023
  • As various accidents have occurred in underground spaces, we aim to improve the quality validation standards and methods as specified in the Regulations on Producing Integrated Map of Underground Spaces devised by the Ministry of Land, Infrastructure and Transport of the Republic of Korea for a high-quality integrated map of underground spaces. Specifically, we propose measures to improve the quality assurance of pipeline-type underground facilities, the so-called life lines given their importance for citizens' daily activities and their highest risk of accident among the 16 types of underground facilities. After implementing quality validation software based on the developed quality validation standards, the adequacy of the validation standards was demonstrated by testing using data from two-dimensional water supply facilities in some areas of Busan, Korea. This paper has great significance in that it has laid the foundation for reducing the time and manpower required for data quality inspection and improving data quality reliability by improving current quality validation standards and developing technologies that can automatically extract errors through software.

Characteristics of Ground-Penetrating Radar (GPR) Radargrams with Variable Antenna Orientation

  • Yoon Hyung Lee;Seung-Sep Kim
    • 자원환경지질
    • /
    • 제57권1호
    • /
    • pp.17-23
    • /
    • 2024
  • Ground penetrating radar (GPR) survey is a geophysical method that utilizes electromagnetic waves reflecting from a boundary where the electromagnetic property changes. As the frequency of the antenna is about 25 MHz ~ 1 GHz, it is effective to acquire high resolution images of underground pipe, artificial structure, underground cavity, and underground structure. In this study, we analyzed the change of signals reflected from the same underground objects according to the arrangement of transceiver antennas used in ground penetrating radar survey. The antenna used in the experiment was 200 MHz, and the survey was performed in the vertical direction across the sewer and the parallel direction along the sewer to the sewer buried under the road, respectively. A total of five antenna array methods were applied to the survey. The most used arrangement is when the transmitting and receiving antennas are all perpendicular to the survey line (PR-BD). The PR-BD arrangement is effective when the object underground is a horizontal reflector with an angle of less than 30°, such as the sewer under investigation. In this case study, it was confirmed that the transmitter and receiver antennas perpendicular to the survey line (PR-BD) are the most effective way to show the underground structure. In addition, in the case where the transmitting and receiving antennas are orthogonal to each other (XPOL), no specific reflected wave was observed in both experiments measured across or parallel to the sewer. Therefore, in the case of detecting undiscovered objects in the underground, the PR-BD array method in which the transmitting and receiving antennas are aligned in the direction perpendicular to the survey line taken as a reference and the XPOL method in which the transmitting and receiving antennas are orthogonal to each other are all used, it can be effective to apply both of the above arrangements after setting the direction to 45° and 135°.

경량기포혼합토로 뒷채움된 연성매설관의 거동특성 (Behavior Characteristics of Underground Flexible Pipe Backfilled with Lightweight Foamed Soil)

  • 이용재;여규권;박상원;김홍연
    • 한국지반신소재학회논문집
    • /
    • 제14권1호
    • /
    • pp.43-50
    • /
    • 2015
  • 본 연구에서는 현장잔토를 활용할 수 있고 다짐이 불필요하여 관로공사에 유용한 경량기포혼합토를 지중매설관의 뒷채움재로 이용할 경우 관로의 거동을 조사하기 위하여 시험시공을 실시하고 계측결과를 분석하였다. 동시에 동일한 조건의 새만금 준설토사 뒷채움 시공결과와 비교하였다. 연직토압의 경우 경량기포혼합토 뒷채움 시 준설토사 대비 초기 슬러리 상태에서 25.6% 가량 저감되었고 양생 후에는 준설토사 토압의 10% 이내에 불과하였다. 준설토사 뒷채움 시에는 경량기포혼합토 대비 수평토압의 경우 3.6배 이상, 연직 및 수평변위는 각각 3.2배와 2.6배 가량의 차이를 나타내어 경량기포혼합토의 토압 및 변위저감 효과가 우수한 것으로 나타났다. 매설관 상반부에서 측정된 응력의 경우 토사 뒷채움 시 대체로 압축응력이 발생한 반면, 경량기포혼합토를 타설한 경우 초기 슬러리 상태에서 발생한 부력으로 인하여 고정된 양단부를 지점으로 부(-)의 모멘트가 발생함으로써 상반부에 인장응력이 발생하는 결과를 얻었다. 결론적으로, 새만금에서 준설된 토사를 이용한 경량기포혼합토는 인근 개발지에서 매설관 뒷채움재로 활용하는데 있어 준설토사와 비교하여 매우 우수한 재료이나 타설 시 부력에 대한 대책이 필요하다.

바톰애쉬를 이용한 지하매설관용 유동성뒤채움재의 FEM 해석 (FEM Analysis of Controlled Low Strength Materials for Underground Facility with Bottom Ash)

  • 이관호;이경중
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2368-2373
    • /
    • 2012
  • 본 연구에서는 유동성뒤채움재와 일반모래뒤채움재를 이용한 지하매설관 시공시 발생하는 관의 변형 및 지표면변위를 유한요소해석을 이용하여 평가하였다. 해석에 사용된 조건은 2개의 관종(연성관인 PE관, 강성관인 콘크리트 흄관), 2개의 매설관 직경(30cm 및 60cm), 2개의 매설관 부설깊이(60cm, 150cm), 2개의 굴착폭(1.5D 및 2D), 5종의 뒤채움재(일반모래 및 4종의 유동성뒤채움재) 등을 이용하여, 다양한 조합의 해석을 수행하였다. 연성관인 PE관의 경우 직경 60cm 매설관의 수직변위가 직경 30cm 매설관의 수직변위 보다 평균적으로 3배이상 크게 나타났다. 또한 일반모래 뒤채움시 0.320mm로 나타났고, 이에 비해 유동성뒤채움재를 이용한 Case B, C, D, 및 E에서의 수직변위는 0.135-0.155mm 로 일반모래 뒤채움에 비해 약 40% 수준의 변위가 발생하였다. 강성관인 콘크리트 흄관의 경우 직경 30cm인 경우 수직변위는 뒤채움재 종류에 상관없이 0.004mm 정도이다. 직경 60cm 인 경우 일반모래 뒤채움재의 경우 0.636mm, 유동성 뒤채움재의 경우 0.081-0.121mm 범위로 나타났다. 부설깊이에 따른 유동성뒤채움의 효과는 연성관인 PE관에서 더 크게 나타났다. 강성관인 콘크리트흄관의 경우 부설깊이에 따른 일반모래뒤채움과 유동성뒤채움재에 따른 차이는 거의 없는 것으로 나타났다.

지반 물성값에 따른 항타 진동이 지중 삼중관에 미치는 거동 분석 (Effect of Pile Driving on Three Layered Pipeline according to Soil Properties Variation)

  • 유한규;최정현;원종화;김문겸
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.765-770
    • /
    • 2010
  • In this study, the behavior of underground pipeline subjected to pile driving is examined using the verified finite element model based on the field experiment. Young's modules of surface soil is varied and elastic modulus of the other soil layer is fixed. The pile driving force model proposed by Mounir E. Mabsout in 1999 was used and it was functions of time and of force. The forcing function applied on this study considers the kinetic energy of ram located at 1.2m height with 7 tonf. The 3-layered pipeline is composed of steel(inner) pipe, PUR(Polyurethane Resin, filler) and HDPE(outer) pipe, and the length/diameter of main steel pipe is 20m/0.8m(O.D). It is used for district heating pipes in Korea. The results are expressed in terms of Von Mises stress, displacement, and vibration velocity for each soil condition. From the results of the analyses, PUR which is originally intended as a thermal insulation of inner pipe shows performance as a structural member which distributes external pressure.

  • PDF