• Title/Summary/Keyword: Underground Parking Lots

Search Result 78, Processing Time 0.043 seconds

A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments (공동주택 지하 주차장 기초형식 선정방법에 관한 연구)

  • Im, Nam-Gi;Lee, Yeong-Do;Bae, Yong-Hwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

Numerical Evaluation of CO Gas Distribution in Underground Parking Lot (지하주차장 내부 일산화탄소 가스 분포의 전산 해석적 평가)

  • Kim Jae Won;Ham Kyoung-A
    • Journal of computational fluids engineering
    • /
    • v.7 no.2
    • /
    • pp.33-42
    • /
    • 2002
  • Numerical estimation for concentration of mono-carbon oxygen (CO) gas inside an underground parking lot with auxiliary jet fans for enhancement of ventilation is carried out by using a commercial program. Main interest lies on the diagnosis of the present ventilation system including position and selection of auxiliarly fans in addition to main suppliers and exhausts. Details of both flows and concentration of CO gas that is most important component among car exhaust gases are illustrated in this investigation and those are presented for engineering construction of an underground parking pool. Prediction data of computational work is also validated by real measurements of concentration of CO gas.

A Study on the Plans of Apartments Underground Parking lots to Prevent Women's Criminal fear Psychology - Focused on apartment design competitions of Suwon A region - (여성의 범죄불안심리를 고려한 공동주택의 지하주차장 계획 연구 - 수원A지구 공동주택 현상설계를 중심으로 -)

  • Li, Jin-Ji;Kim, Nam-Hyo
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.104-114
    • /
    • 2009
  • The purpose of study was understanding necessity of environment design for underground parking lot in residential design plan and grasping design plans of 'Activity Support' that considerate women, exclude women's unsecured feeling at underground parking lot. The inquiry analyzed 6 design plan in design competition that considerate women according to precede studies, a theory of CPTED, a design guide for wayfinding, and survey. A ramp, circulation, entrance, lighting, ventilation, and space design plan are proceed on this study The result are as below. First, a rectilinear figure ramp suits entrance plan on the circulation, but if it is not possible, cross-using of rectilinear and curvilinear figure ramp plan is desirable. Second, on the circulation plan, vehicles circulation plan and equality parking distribution plan got accomplished generally, and help senses of direction because it is planed network systemize. On a large scale underground parking lot, simplify parking circulation to convenience entrance and exit for weak in sense of direction. Third, the shape and material that‘s environmentally conscious will be in use to the entrance plan. As the first stage to the underground, artwork that women prefer can modulate the rejection of underground space. Forth, natural lighting system and ventilation can make the environment-friendly space, decrease the women’s rejection to the underground, it can also keep a natural watch on the space. Fifth, on the space design plan, it can use bright and comfortable design of wall and ground to decrease the women‘s rejection, also it is useful to the sense of direction. LED indirect lighting plan that 58.7% of women prefers on survey reflects women’s state of desire that bright and atmosphere. In addition, proper use of plans that subsidiary facilities, rest area with Sunken, and nature-friendly material can minimize differences of underground and ground parking lot.

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

Structural Analysis of Underground Parking Garage Under Vehicle Load (지하주차장 차량하중에 따른 구조체의 영향분석)

  • Kim, Young-Jin;Lee, Bum-Sick;Choi, Dong-Sub;Oh, Hyo-Keon;Kang, Chang-Bum
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.22-29
    • /
    • 2013
  • Accumulation of more than 20,000,000 vehicles since the establishment of the quality of life and economic development needs several parking lots and cause crack problem in Korea. Related structures in large cities due to the lack of parking garage attached to secure underground parking structures are actively being built, and the basement parking lot will continue to increase more stories and the trend is expected to be larger. But so far, construction of the underground parking structure is related to a number of problems, including cracks in the structure. Therefore, in this study, repair, reinforcement and a few non-economic losses in the current design criteria are presented. The review of the structure used to current design criteria is to minimize crack and maximize usability.

A System of Guiding Path for Parking Lots based on RFID to Consider Real-time Constraints (실시간 제약을 고려한 RFID 기반 주차 경로 안내 시스템)

  • Kang, Ku-An;Kim, Jin-Deog
    • Spatial Information Research
    • /
    • v.16 no.1
    • /
    • pp.65-77
    • /
    • 2008
  • There have been many studies and technologies that define a current location of a moving vehicle with GPS(Global Positioning System). However, the navigation system with GPS has troubles to search an optimized route considering data such as realtime parking status and road conditions. Moreover, the GPS systems show malfunction in the downtown with very tall buildings, underground parking lot and the inside of buildings. On the contrary, the RFID systems are able to reflect real-time status of parking lots and roads in the downtown. This paper proposes a system of guiding path for parking lots to consider real-time constraints based on RFID. The results obtained from the implemented system show smooth guiding of a new route after immediately sensoring the change of the information of parking lots and roads: if a parking lot that a vehicle is heading to is fully occupied, the system re-searches a new route for a neighbor parking lot and immediately transfers it to customer's mobile, and if the designated route is under construction, the system guides a detour path. The proposed method will be useful for advanced integrated parking control system.

  • PDF

Indoor and Outdoor Formaldehyde Concentrations in Underground Environments (실내외 포름안데히드 농도에 관한 조사연구)

  • 김윤신;김미경
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.