• Title/Summary/Keyword: Underground Information

Search Result 811, Processing Time 0.026 seconds

Analysis of Position Accuracy for Underground Facility Using RTK-GPS (RTK-GPS를 이용한 지하시설물의 위치 정확도 분석)

  • 박운용;이종출;정성모
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.237-243
    • /
    • 2003
  • The complicated facilities on the ground have begun to be laid under the ground as increasing emphasis on the beauty of cities due to centralization. But, as the kind of the facilities have been concentrated on the narrow area, accidents occur due to the difficulty of maintenance and the inaccuracy of location information. In this study, first we constructed the field test model to compare with the method of underground probing. So, we could know that the electromagnetic induction method and GPR(Ground Penetration Radar) are useful. It was acquired the position information for the underground facilities using a RTK-GPS. As the result, we have analyzed the accurate position of the underground facility and show the way improving accuracy in detecting and surveying comparing with the traditional surveying method. Also, we hope to contribute the effective maintenance and prevention of disasters to the underground facility as using underground facilities 3D position with Arcview and building the DB of exact depth and underground facilities information system.

Design and Implementation of the Lamp Control System in Underground Parking Place using Web (웹을 이용한 지하주차장 조명제어시스템의 설계 및 구현)

  • Shon, Hyung-Do;Shin, Dong-Uk;Kang, Seung-Chan
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.3
    • /
    • pp.42-50
    • /
    • 2002
  • In this paper, we have designed and implemented lamp control system in underground parking place using WWW. The proposed system consists of lamp control system which is connected by RS-485 communication bus and monitoring system (WebPL) which can provide web interface using the web server. The lamp control system is controlled through a user command within the monitoring system (WebPL), senses moving object and turns lamps in underground parking place on or off. The monitoring system displays the status values of on or off received from lamp control system on the web browser and can real-timely control lamps in underground parking place on the web browser. 

Real-time Underground Facility Map Production Using Drones (드론을 이용한 실시간 지하시설물도 작성)

  • NO, Hong-Suk;BAEK, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.4
    • /
    • pp.39-54
    • /
    • 2017
  • Between 1998 and 2010, the computerization of underground facilities was completed in 84 cities. Since 2011, new pipelines have been laid or existing pipelines have been maintained, renovated, and renewed. To measure the exact location and depth of the exposure pipe, a map of underground facilities was created before filling the ground. This method is based on the time when the underground facilities of the National Geographic Information Institute Regulation No. 134 of the National Geographic Information Office revised in 2010 were drafted. The process of the drone taking the video is based on a theoretical basis of ground control points. The method works by removing all ground control points located outside of the error range and re-processing it for calculating the best result. Furthermore, using a drone-based spontaneous measuring method allows workers to obtain a high accuracy underground facilities map in error bound. The proposed method could be used as a new way to standardize the processing.

Land Development Project Area Underground Facility Management A Plan Using GIS (GIS를 활용한 택지개발사업지구 지하시설물 관리방안)

  • 김감래;이재기;임건혁
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.329-334
    • /
    • 2003
  • The aim of this study is propriety review for underground facility surveying on development area of land for housing and efficient management. Because of integration information administration system construction of the nation and development of information technology, construction of Urban information system(UIS) to manage systematically city space is increasingly necessary We manage systematically attribute information for each lot in the development area of land lot housing that it Is connected with NGIS in order to drive gradual computerization of underground facilities and arrange the base of facility management. Review arrangement methods on development area of land for housing makes it to check safety accident of urban and to leading base of urban information. Thus, this study draw the most suitable way through analysis of driving methods and expectation effect from above facts.

  • PDF

Reliability Evaluation Methodology of Boring Investigation DB for the 3D Integrated Underground Space Map (3차원 지하공간통합지도 구축을 위한 시추조사 DB의 신뢰도 검증 방안)

  • Lee, Boyoung;Hwang, Bumsik;Cho, Wanjei
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.9
    • /
    • pp.35-47
    • /
    • 2017
  • Recently, the 3D image of the geotechnical information has been constructed along with the 3D integrated underground space mapping project. Prior to the visualization of the 3D image of the geotechnical information, it is necessary to analyze and verify the accuracy of the geotechnical information. Previous studies evaluated the precision of collected geotechnical information DB to validate the quality of the collected DB and later studies on the 3D precision were performed to provide the basic data for the 3D integrated underground space map. In this study, practical application methodologies are suggested based on the previous studies to improve the accuracy of the applied geotechnical information and further to improve the reliability of the constructed 3D integrated underground space map.

The Establishment Plan of Knowledge-Based Community through the 3-D National Underground Information DB Design and Utilization Review (3차원 국토지하정보 DB설계 및 활용성 검토를 통한 지식기반 커뮤니티 구축 방안)

  • Song, Seok-Jin;Jang, Yong-Gu;Kang, In-Joon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.1
    • /
    • pp.63-70
    • /
    • 2011
  • The national spatial information systems project which is promoted by our country has been extended from existing 2-D geographic information to 3-D spatial information as the basic geo-spatial Information. Most of the construction of the ground geo-spatial information are completed or underway, on the other hand, the construction of the subsurface geo-spatial information has difficulty caused by the lack of the drilling data characterizing the subsurface. In terms of the construction of the geo-spatial information of the subsurface, the subsurface information is constructed and managed by the domestic institutions, but the subsurface information which is possessed by the institutions was not shared mutually so it is managed inefficiently. This study presented the 3-D national underground information DB design by dividing with the ground DB item which configures the state of the ground and the soil DB item which configures the state of the soil in order to increase the efficiency of the construction of the subsurface spatial information. The implementation & utilization of the national underground information application technology was reviewed by applying the constructed DB to the actual model area, and the national underground information knowledge-based community establishment plan was presented.

Improving the Detection of the Water Mains Underground Facilities (상수도 지하시설물 탐사 개선에 관한 연구)

  • Kim, Jae-Myeong;Lee, Byung-Woon;Choi, Yun-Soo;Yoon, Ha-Su
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.23-32
    • /
    • 2010
  • Water mains underground facilities are essential components to make up urban infrastructure. In order to manage these water mains underground facilities systematically and scientifically, GIS (Geographic Information System) had been constructed. For the sake of construction of GIS for water mains underground facilities, an exact underground detection and the construction of DB (Data Base) for buried water mains underground facilities should be preceded. In this study, in order to find out the ways to improve exact detection rate of data, the statistical analysis for the causes of detection raw degradation was done, and standardization methods of detection through a case study were suggested, When water mains underground facilities were measured, the detection of non-metallic water pipes was not carried out. The reason was that the results of detection was uncertain and detection was difficult because the assessment of public measurements was vulnerable. Moreover, due to the absence of standardized operating regulations for detection, systematic surveys weren't conducted. In this study, methods to standardize works over the detection of water mains underground facilities were presented so that we can improve the detection rate when we are doing that. As the proposals to improve detection rate, effective performance assessment over non-metallic pipes were presented, and related issues to supplement work regulations of public survey were described systematically.

A Study on the Planning of Escape Facilities of Underground Space at Fire. -a case study at Underground Shopping Street- (화재시 지하공간의 피난시설계획에 관한 연구 -지하가를 중심으로-)

  • 이원석;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.1
    • /
    • pp.13-19
    • /
    • 1990
  • Recently, the expansion of underground shopping street has a tendency to make a large maze in urban underground space. As the passers -by in underground streets have little information about these spaces, there can be a great danger at fire. From this point of view, this study aims at offering the basic data which needs to make a reasonable planning of escape facilities of underground shopping street. Therefore, safe performance evaluation program is developed for evaluating inhabitants' safety at each model. This program is composed of systematic equations which generalize each phenomenon at fire.

  • PDF

Development of Underground Facilities Management System on Subway Construction (지하철공사를 위한 지하매설물관리시스템 개발)

  • 강인준;장용구;정영미
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.75-80
    • /
    • 1997
  • In other to construct a subway, we have to consider the position of the subway and acquisition of a topography, profile-map, cross-map, underground facilities map. All information of underground is demanded accurate location in other to prevent of accident of underground in subway construction. We must think about water lines, sewer lines, electronic lines, telephone lines, all urban gas-line because these are needed construction the subway. And attributes of underground facilities recorded on topography are characteristics. length, width. number, position, and depth of the lines. We have to record these attributes because these are very important to design map on subway construction. If we develop GIS (Geographic Information System) to use the exact in-formation of the underground facilities, we can be management safely and prevent very dangerous accident as fast as possible. In this study, attribute informations are linked geographic informations about underground facilities and we can develop Underground Facilities Management System(UFMS) to analysis dangerous region through dangerous degreed and predict accident range with these informations.

  • PDF

Implementation of condition monitoring system in underground utility tunnels using inductive coupler (유도성 커플러를 이용한 지하공동구의 상태감시시스템)

  • Ju, Woo-Jin;Kim, Hyun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1597-1603
    • /
    • 2017
  • The incidence of fire in underground utility tunnel is lower than other fires, but the damage caused by fire can cause social loss due to social management paralysis as well as economic loss. Hereupon, this paper presents the results of an empirical test on the construction of the underground utility tunnel condition monitoring system using the leakage coaxial cable installed in the underground utility tunnel. For this reason, a verification test was conducted by connecting a inductive coupler 200 Mbps power line communication modem with insertion loss characteristics of $-6{\pm}2dB$ to the installed the leakage coaxial cable installed in the underground utility tunnel. As a result, We confirmed sending/receiving of IP cameras up to 500 m. Therefore, it is judged that it is possible to construct a condition monitoring system for underground utility tunnel by using the leakage coaxial cables installed in the underground utility tunnels without installing additional communication lines for data transmission.