• Title/Summary/Keyword: Underground Facility

Search Result 379, Processing Time 0.027 seconds

Universal Design in Main Entrance Space of Underground Passage Shopping Center (지하도상가 주출입 공간의 유니버설 디자인 적용 현황에 관한 연구)

  • Lee, Hyo-Chang;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.99-102
    • /
    • 2007
  • Underground passage shopping center which is one of the underground space is a public facility. Therefore, underground passage shopping center needs physical environment that everyone (such as ordinary adults, seniors, disabled and ETC) could use it without any difficulties. The purpose of this research is to evaluate the application of universal design into main entrance space of underground passage shopping center. The scope of this research was adjusted as 8 underground passage shopping centers that are located in Seoul. Spacial scope of the research was set as public space such as main entrance space, slope way, stairway of underground passage shopping center and the content of scope of this research was the application of universal design. The conclusion of this research is as following. First, public space of underground passage shopping center needs physical environmental improvement for the convenient usage for seniors and disabled. Second, the application of universal design is needed for public space for shelter and rescue of underground passage shopping center. Third, Underground passage shopping center needs a plan to minimize the safety infringement of user by commercial activity of stores in it.

  • PDF

Detailed Analysis of the KAERI nTOF Facility

  • Kim, Jong Woon;Lee, Young-Ouk
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.141-147
    • /
    • 2016
  • Background: A project for building a neutron time-of-flight (nTOF) facility is progressing. We expect that the construction will start in early 2016. Before that, a detailed simulation based on the current architectural drawings was performed to optimize the performance of our facility. Materials and Methods: Currently, several parts had been modified or changed from the original design to reflect requirements such as the layout of the electron beam line, shape of the vacuum chamber producing a neutron beam, and the underground layout of the nTOF facility. Detailed analysis for these modifications has been done with MCNP simulation. Results and Discussion: An overview of our photo-neutron source and KAERI nTOF facility were introduced. The numerical simulations for heat deposition, source term, and radiation shielding of KAERI nTOF facility were performed and the results are discussed. Conclusion: We are expecting that the construction of the KAERI nTOF facility will start in early 2016, and these results will be used as basic data.

Status and Accuracy Analysis of Underground Facility Maps (지하시설물도 현황 및 정확도 분석)

  • Bae, Kyoung-Ho;Heo, Min;Lee, Yong-Wook;Jeong, Eui-Hwan
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.231-235
    • /
    • 2007
  • As the centralization of city, underground facilities is increasing and being more important. And there were many underground facilities accidents in korea. It is very important to update and to have high quality accuracy of underground facilities maps. But the underground facilities maps are mapped and updated by each institutes. So it is difficult to verify the accuracy of the data. In this study, To analyze the accuracy of maps, Surveying of undergroud facilities for 18 GUs in Seoul is performed during 3 years using Electromegnetic Induction Method, Total Station and GPS. In conclusion, Horizontal accuracy of 6 underground facilities management institutes is 73cm(2004), 78cm(2005) and 75cm(2006).

  • PDF

Decision technique for accommodation facilities of multi-utility tunnel in basic planning phase (기본 계획 단계에서의 공동구 수용시설물 결정 기법)

  • Oh, Won-Joon;Jin, Kyu-Nam;Kang, Yeong-Ku;Cho, Choong-Yeun;Sim, Young-Jong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.79-92
    • /
    • 2019
  • In this paper, we propose a method to determine whether to install the accommodation facility of the multi-utility tunnel more effectively in the basic planning phase, and to set up an evaluation system to determine the configuration and kind of accommodation facility. For the configuration of the accommodation facility, 98 alternatives were analyzed for 7 accommodation facility. For the evaluation system of the accommodation facility, index related to feasibility and economic in basic planning phase were selected. The evaluation system classified as spatial, effective, and cost evaluation was presented reflecting the selected index, and AHP analysis was performed for weight setting. The results of this study will be helpful for users including designers to shorten the time and increase the efficiency in the process of determining accommodation facility of the multi-utility tunnel in basic planning phase.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

Current Status and Tasks of Contaminant Migration Experiment Using Underground Research Laboratory (지하연구시설을 이용한 오염물질 이동실험 현황 및 과제)

  • Park, Chung-Kyun;Baik, Min-Hoon;Choi, Jong-Won
    • Tunnel and Underground Space
    • /
    • v.17 no.1 s.66
    • /
    • pp.17-25
    • /
    • 2007
  • Research and development for disposal of contaminants including radioactive wastes in deep underground have been carried out from laboratory works. However, validation and reliability of the data from the laboratory are arguing issues because they are not obtained from real disposal situations. Underground research laboratory (URL) is not only a solution to overcome such limitations, but also a valuable facility for performance assessment as an engineering scale. However, it requires much budget, and environmental issues can give rise to social conflicts easily. Such considering points related to URL are discussed as well as current status of worldwide URLs are introduced. Furthermore study plans for solute transport in a small-scale underground research tunnel (KURT), which was authorized recently as an non-radioactive facility in Korea, also described.

Real-time Underground Facility Map Production Using Drones (드론을 이용한 실시간 지하시설물도 작성)

  • NO, Hong-Suk;BAEK, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.4
    • /
    • pp.39-54
    • /
    • 2017
  • Between 1998 and 2010, the computerization of underground facilities was completed in 84 cities. Since 2011, new pipelines have been laid or existing pipelines have been maintained, renovated, and renewed. To measure the exact location and depth of the exposure pipe, a map of underground facilities was created before filling the ground. This method is based on the time when the underground facilities of the National Geographic Information Institute Regulation No. 134 of the National Geographic Information Office revised in 2010 were drafted. The process of the drone taking the video is based on a theoretical basis of ground control points. The method works by removing all ground control points located outside of the error range and re-processing it for calculating the best result. Furthermore, using a drone-based spontaneous measuring method allows workers to obtain a high accuracy underground facilities map in error bound. The proposed method could be used as a new way to standardize the processing.

Analysis of Ground Subsidence Influencing Factors Using Underground Facility Property Information (지하매설물 속성정보를 활용한 지반함몰 영향인자 분석)

  • Jaemo Kang;Sungyeol Lee;Jinyoung Kim;Myeongsik Kong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.1
    • /
    • pp.5-11
    • /
    • 2024
  • Ground subsidence mainly occurs in urban areas with high population density, so it is necessary to clearly identify the cause of occurrence and prepare in advance. The main cause of ground subsidence is reported to be the creation of cavities in the ground due to damage to underground pipes, but the property information and influencing factors of underground pipes to predict and prepare for ground subsidence are not properly established. Therefore, in this study, factors showing a significant correlation with the occurrence of ground subsidence were selected among the underground facility property information and a regression equation was proposed through logistic regression analysis. For this purpose, data on underground structures and ground subsidence history information in the target area were collected, and the target area was divided into girds of 100m x 100m in size using QGIS. The underground facility attribute information and ground subsidence history information contained within the gird were extracted. Then, preprocessing was performed to construct a dataset and correlation analysis was performed. As a result, factors excluding the year of sewer pipes and communication pipes and the average depth of communication pipes, heat pipes, and gas pipes were found to have a significant correlation with ground subsidence. In addition, a regression equation for whether ground subsidence occurred in the target area is proposed through logistic regression analysis.

Sensitivity Analysis Study of Geotechnical Factors for Gas Explosion Vibration in Shallow-depth Underground Hydrogen Storage Facility (저심도 지하 수소저장소에서의 가스 폭발 진동에 대한 지반공학적 인자들의 민감도 분석 연구)

  • Go, Gyu-Hyun;Woo, Hyeon‑Jae;Cao, Van-Hoa;Kim, Hee-Won;Kim, YoungSeok;Choi, Hyun-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.4
    • /
    • pp.169-178
    • /
    • 2024
  • While stable mid- to large-scale underground hydrogen storage infrastructures are needed to meet the rapidly increasing demand for hydrogen energy, evaluating the safety of explosion vibrations in adjacent buildings is becoming important because of gas explosions in underground hydrogen storage facilities. In this study, a numerical analysis of vibration safety effects on nearby building structures was performed assuming a hydrogen gas explosion disaster scenario in a low-depth underground hydrogen storage facility. A parametric study using a meta-model was conducted to predict changes in ground dynamic behavior for each combination of ground properties and to analyze sensitivity to geotechnical influencing factors. Directly above the hydrogen storage facility, the unit weight of the ground had the greatest influence on the change in ground vibration due to the explosion, whereas, farther away from the facility, the sensitivity of dynamic properties was found to be high. In addition, in evaluating the vibration stability of ground building structures based on the predicted ground vibration data and blasting vibration tolerance criteria, in the case of large reinforced concrete building structures, the ground vibration safety was guaranteed with a separation distance of about 10-30 m.