• Title/Summary/Keyword: Underdrain

Search Result 9, Processing Time 0.022 seconds

Theoretical Analysis of Soil Desalination Characteristics for Underdrain System at Reclaimed Tidal Land (간척지 흙의 암거 설치조건에 따른 제염 특성의 이론적 해석)

  • Kim, Hyuntai;Seo, Donguk;Yoo, Chanho;Kim, Seogyeol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.87-92
    • /
    • 2015
  • Cultivation on reclaimed tidal land is often difficult in the problem such as high salinity of soil, bad drainage because of high level of groundwater. Many researches have been made efforts to solve these problems, but effect of improvement is low and practicality is insufficient. In this study, through numerical analysis of the transport properties of salt and water, we suggested underground drainage of the reclaimed land and the desalination promotion methods in the soil. The results of characteristic of desalination and seepage analysis of underdrain show that underdrain is able to increase twice of the underground seepage amount when installing perforated pipe with horizontal filter (width 50cm) more than installing only the perforated pipe. For soil which coefficient of permeability is below $1{\times}10^{-4}cm/s$ that desalination with pond water is not possible, a method to increase the permeability of the soil is necessary. Therefore, it was concluded that application of underdrain using perforated pipe with horizontal filter would be low-cost and practical.

Diagnosis and Renovation of a Time-worn Rapid Sand Filter used for Drinking Water Treatment (정수장의 노후 급속 모래여과지 진단 및 개량)

  • Kim, Sang-Goo;Park, Hyun-Seog;Son, Hee-Jong;Lee, Jeong-Gyu;Ryu, Dong-Choon;Yoo, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.999-1005
    • /
    • 2016
  • The H water treatment plant has been operating since 1982 and has had no renovation. It is assumed that the filters have been operated for more than 30 years and therefore are deteriorated. Many of the filters show an unequal state of air scouring during backwashing. For this study one filter, which was presumed most deteriorated among eighteen filters, was selected as a model filter for renovation. Some of the effects seen after renovation of the underdrain system were a lower average filtrated turbidity by approximately 0.02 NTU and an equal backwash state throughout the filter bed. Sand wash efficiencies by backwash before renovation of the underdrain system were 28%, 8%, and 5% at the surface, 50 cm depth, and 100 cm depth, respectively, and after renovation of the underdrain system were 94%, 26%, and 15%, respectively. The standard deviation of the effective sand size was 0.025-0.033 mm before renovation of the underdrain system and 0.002-0.011 mm after renovation of the underdrain system, meanings there was equal backwash pressure throughout the filter. Filtration time after renovation was approximately 2 times longer than before renovation.

In-situ Hydraulic Conductivity Testing Methods (현장 투수시험 방법)

  • Kwon Moo-nam
    • KCID journal
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 1995
  • 현장 투수시험 방법 중에서 Borehole type의 Boutwell Permeameter와 Constant head bore-hole permeameter, 그리고 Porous probe type의 cone shaped porous probe(BAT Permeameter)에 대한 내용을 간단히 소개하였고, 각 측정법의 특징을 비교분석한 내용을 요약하면 (표-1)과 같으며, 기회가 있으면 Infiltrometer type와 Underdrain type에

  • PDF

Design and Application of Subsurface Drainage Devices for Multipurpose Farmland

  • Jeon, Jong Gil;Choi, Yong Hun;Kim, Min Young;Kim, Young Gjin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.265-275
    • /
    • 2017
  • Purpose: This study aims to identify the most stable boring shape among the circle, square, and inverted-triangle types in order to be applied to the development of a tractor-pulled underdrain boring device. Methods: The underdrain boring devices designed with the circle, inverted triangle, and square types were analyzed by numerical analysis, and they were evaluated by soil moisture and underground water level in the test field. Results: The results of the numerical analysis indicated that the increases in displacement, and strain when a uniform load is placed on the surface soil with soil weight were in the order of the inverted-triangle type, square type, and circle type. The soil moisture content and the underground water level after rainfall showed the largest difference in the order of the circle type, square type, and inverted-triangle type, indicating that the circle type had the largest drainage effects after rainfall. Conclusions: The overall findings of this study show that the circle type is the most stable among the circle, square, and inverted-triangle types.

Modeling the effects of excess water on soybean growth in converted paddy field in Japan 1. Predicting groundwater level and soil moisture condition - The case of Biwa lake reclamation area

  • Kato, Chihiro;Nakano, Satoshi;Endo, Akira;Sasaki, Choichi;Shiraiwa, Tatsuhiko
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.315-315
    • /
    • 2017
  • In Japan, more than 80 % of soybean growing area is converted fields and excess water is one of the major problems in soybean production. For example, recent study (Yoshifuji et al., 2016) suggested that in the fields of shallow groundwater level (GWL) (< 1m depth), rising GWL even in a short period (e.g. 1 day) causes inhibition of soybean growth. Thus it becomes more and more important to predict GWL and soil moisture in detail. In addition to conventional surface drainage and underdrain, FOEAS (Farm Oriented Enhancing Aquatic System), which is expected to control GWL in fields adequately, has been developed recently. In this study we attempted to predict GWL and soil moisture condition at the converted field with FOEAS in Biwa lake reclamation area, Shiga prefecture, near the center of the main island of Japan. Two dimensional HYDRUS model (Simuinek et al., 1999) based on common Richards' equation, was used for the calculation of soil water movement. The calculation domain was considered to be 10 and 5 meter in horizontal and vertical direction, respectively, with two layers, i.e. 20cm-thick of plowed layer and underlying subsoil layer. The center of main underdrain (10 cm in diameter) was assumed to be 5 meter from the both ends of the domain and 10-60cm depth from the surface in accordance with the field experiment. The hydraulic parameters of the soil was estimated with the digital soil map in "Soil information web viewer" and Agricultural soil-profile physical properties database, Japan (SolphyJ) (Kato and Nishimura, 2016). Hourly rainfall depth and daily potential evapo-transpiration rate data were given as the upper boundary condition (B.C.). For the bottom B.C., constant upward flux, which meant the inflow flux to the field from outside, was given. Seepage face condition was employed for the surrounding of the underdrain. Initial condition was employed as GWL=60cm. Then we compared the simulated and observed results of volumetric water content at depth of 15cm and GWL. While the model described the variation of GWL well, it tended to overestimate the soil moisture through the growing period. Judging from the field condition, and observed data of soil moisture and GWL, consideration of soil structure (e.g. cracks and clods) in determination of soil hydraulic parameters at the plowed layer may improve the simulation results of soil moisture.

  • PDF

Investigation on Carbonation Phenomenon of Type of Use for Concrete Structures aged a decade to fifty years ($10{\sim}50$년이 경과한 콘크리트구조물의 사용 용도별 탄산화 현상에 의한 열화도 판정)

  • Park, Hyun;Kim, Kwang-Ki;Han, Da-Hee;Kim, Sung-Jin;Lim, Nam-Gi;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1017-1020
    • /
    • 2008
  • Carburization at concrete structures is being processed independently or compositively and each unique Carburization will appear depending on the condition of circumstance. Therefore, the depletion rate was being estimated at this research for buildings and civil construction structures of different environments and of more than 10 - 60 years old by calculating the depth of carburization and the density of Alkali. As the results of the test, buildings (interior) had a deeper and a faster carburization than civil construction structures being exposed to open air as closer to the shore. And also, concrete structures being used as an underdrain of sewage were proven to have a deeper carburization than utility-pipe conduits or underground tunnels.

  • PDF

Effect of reaction temperature and time on the formation of calcite precipitation of recycled concrete aggregate (RCA) for drainage applications

  • Boo Hyun Nam;Jinwoo An;Toni Curate
    • Geomechanics and Engineering
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 2023
  • Recycled concrete aggregate (RCA) is widely used as a construction material in road construction, concrete structures, embankments, etc. However, it has been reported that calcite (CaCO3) precipitation from RCA can be a cause of clogging when used in drainage applications. An accelerated calcite precipitation (ACP) procedure has been devised to evaluate the long-term geochemical performance of RCA in subsurface drainage systems. While the ACP procedure was useful for the French Drain application, there remained opportunities for improvement. In this study, key factors that control the formation of calcite precipitation were quantitatively evaluated, and the results were used to improve the current prototype ACP method. A laboratory parametric study was carried out by investigating the effects of reaction temperature and time on the formation of calcite precipitation of RCA, with determining an optimum reaction temperature and time which maximizes calcite precipitation. The improved ACP procedure was then applied to RCA samples that were graded for Type I Underdrain application, to compare the calcite precipitation. Two key findings are (1) that calcite precipitation can be maximized with the optimum heating temperature (75℃) and time (17 hours), and (2) the potential for calcite precipitation from RCA is not as significant as for limestone. With the improved ACP procedure, the total amount of calcite precipitation from RCAs within the life cycle of a drain system can be determined when RCAs from different sources are used as pipe backfill materials in a drain system.

A Study of Wildlife Roadkill in Joongang Highway (우리나라 야생동물의 도로치사에 관한 연구 -중앙고속도로의 동물치사 사례를 중심으로-)

  • Lee, Sang-Don;Cho, H.S.;Kim, J.G.
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.1
    • /
    • pp.21-31
    • /
    • 2004
  • Construction of highway would influence wildlife habitat being fragmented and deteriorated. It is inevitable to observe the death of animals that are killed by vehicles. Nonetheless the cause and status of animal roadkill have not been studied, and this study first attempted to analyze the roadkill in major highway in Korea. We collected 860 individuals of dead animals in Joongang Highway during 1996-2003. Among them Korean hare(Lepus sinensis) was totaled in 165 individuals(19.2%) with the highest figure; Korean racoon dog(Nyctereutes procyonoides) was 146(17.0%); Korean squirrel(Sciurus vulgaris) 56(6.5%); Korean roe deer(Capreolus capreolus) 26(3.0%). Domestic animals was totaled in 232 individuals(27.0%); domestic dog(Canis familiairis) 25, and domestic cat(Catus felis) 207. This study also categorized habitat as mountain-mountain, mountain-plain, mountain-river, plain-plain, plain-river, river-river in each side of the road. Habitat of mountain-plain was the heightest with 296(38.9%) individuals followed by mountain-mountain with 263(34.6%). This indicates that wild animals associated with mountain habitat was most influenced by the construction of roads. This study implied that we should mitigate the roadkill by designing artificial construction such as eco-bridge, fences along the sideway, and boxes under the highway, underdrain structure, etc. The monitoring and cause of habitat fragmentation with GIS approach should be followed to reduce the roadkill.

Applicability Evaluation of Two-stages and Dual Media Filtration System by the Small-scale Pilot Plant (이단이층 복합여과시스템의 소규모 파일롯 플랜트 적용성 평가)

  • Woo, Dal-Sik;Song, Si-Byum;Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.857-864
    • /
    • 2009
  • This study aimed at developing the two stage and dual filtration system. It has a sand + activated carbon layer above the underdrain system and a sand layer above the middledrain system for pretreatment. When retrofitting an old filter bed or designing a new one, this technology can substitute the existing sand filter bed without requiring a new site. In order to extend the filtering duration, the upper layer of the filter bed consists of the rapid sand filtration with large particles which pre-treats and removes coarse particles and turbidity matters. The middle layer has biological activated carbon(BAC) and granular activated carbon(GAC) to eliminate dissolved organic matters, disinfection by-products precursors etc. The lower layer consists of the sand filtration for the post filtering mode. In this study, a pilot plant of two stage and dual filtration system was operated for 4 months in the S water treatment plant in Kyounggi-Do. The stability of turbidity was maintained below 1NTU. The TOC, THMFP and HAAFP were removed about 90% by two stage and dual filtration system, which is almost 2 times higher than S WTP. From analysis result of HPC along the depth of activated carbon + sand layer at 2nd stage, microorganism was mostly not detected, however, increment of HPC was shown as it becomes deeper. It indicates that growth of microorganism is occurred at activated carbon layer.