• Title/Summary/Keyword: Under-used Space

Search Result 1,148, Processing Time 0.023 seconds

Dense Spray Patternation using Optical Tomography

  • Cho, Seongho;Park, Gujeong;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.4
    • /
    • pp.398-407
    • /
    • 2013
  • Optical tomography was used to measure the pattern of spray cross-section. The maximum-likelihood estimation (MLE) algorithm was used to reconstruct the spray cross-section from the measured transmission rate of the spray. A swirl-type injector was used to form an optically dense spray, and the test was carried out in a high-pressure chamber, to control the pressure condition of the test site. Before the experiment, the reliability of the MLE-based reconstruction algorithm was verified, by comparing it with a conventional filtered back projection reconstruction (FBP) method. The MLE algorithm showed superior reconstruction of the image. In the spray patternation experiment, the results of the optical tomography and optical line patternator, which uses Mie scattering signal information, were compared. While measuring the cross-section of optically dense spray, the intensity of the scattering signal had attenuated to an uncorrectable level, which led to incorrect spray pattern measurement by the optical line patternator. However, reliable results were obtained by optical tomography, under the same condition. Finally, the pattern of the optically dense spray was measured at various chamber pressures, of up to 3 MPa. As the chamber pressure increased, the hollow cone-shaped swirl spray shrank, and the attenuation coefficient value of the inner region increased.

Characteization of Space Charge Distribution and Conduction Current in Dielectric material With Temperature (온도에 따른 유전체내에서의 공간전하 분포와 전도전류 특성)

  • Kim, Jin-Kyun;HwangBo, Seung;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1078-1080
    • /
    • 1995
  • The pulsed electro-acoustic method was used as a nondestructive measurement technique of spare charge distribution in dielectric materials. In our work presented here, we measured simultaneously the space charge distribution and conduction current in the low-density polyethylene samples with elevated temperatures up to $80^{\circ}C$ and electric field up to 20kV/mm. In the temperature less than $50^{\circ}C$, homocharges are mainly accumulated close to the electrodes under DC bias and after grounding. At the temperature exeeds $50^{\circ}C$, heterocharges are accumulated near the opposite electrode under DC bias. However after grounding the upper electrode, this charges immediately disappeared. The conduction current in LDPE at $20^{\circ}C$ and $30^{\circ}C$ was reduced slowly with increasing interval of applied voltage. But as temperature increased, the conduction current tended to increase slowly with the time and the degree of increase is enlarged.

  • PDF

Tensile Characteristics of A12024-T3 under Rapid Heating (급속가열환경에서 A12024-T3의 인장특성)

  • Kim, Jong-Hwan;Kim, Jae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.101-108
    • /
    • 2004
  • The thermomechanical tensile characteristics were evaluated for A12024-T3 under heating rates from $1^{\circ}C/sec\;to\;30^{\circ}C/sec$ by using an infrared heating equipment to simulate aerodynamic heating. The rapid heating test results were compared with tensile test results after 1/2 hour exposure in terms of yield stress to investigate the influence of heating condition. A heating rate-yield temperature parameter was suggested for rapid heating based on time-temperature parameters, and master yield stress curve was obtained by using these parameter. These test results can be used for margin of safety of supersonic vehicle structures subjected to aerodynamic heating.

Visible Perforating Lateral Osteotomy: Internal Perforating Technique with Wide Periosteal Dissection

  • Rho, Bong Il;Lee, In Ho;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.88-92
    • /
    • 2016
  • There are two general categories of lateral osteotomy techniques-the external perforating method and the internal continuous method. Regardless of which technique is used, procedural effectiveness is hampered by limited visualization in the surgical field. Considering this point, we devised a new technique that involves using a wide subperiosteal dissection and internal perforation under direct visualization. Using an intranasal approach, whereby the visibility of the intended fracture line was maintained, enabled a greater degree of control, and in turn, results that were more precise, and thus predictable and reproducible. Traditionally, it has been taken as dogma that the periosteum must be preserved, considering the potential for dead space and bony instability; however, under sufficient visualization of the surgical field with an internal perforating method, complete osteotomy with fully preserved intranasal mucosa could be conducted exactly as intended. This intact mucosal lining compensates for the elevated periosteum. Compressive dressing and drainage through a Silastic angio-needle catheter enabled the elimination of dead space. Therefore, precise, reproducible, and predictable osteotomy minimizing the potential for associated complications such as ecchymosis, that is, bruising owing to hemorrhage, could be performed. In this article, we introduce a novel technique for lateral osteotomy with improved visualization.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

Development and Verification Test of a Bi-propellant Thruster Using Hydrogen Peroxide and Kerosene

  • Yu, I Sang;Kim, Tae Woan;Ko, Young Sung;Jeon, Jun Su;Kim, Sun Jin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.270-278
    • /
    • 2017
  • This paper describes development procedure and verification test results of a bi-propellant thruster using hydrogen peroxide and kerosene. The design thrust of the thruster is about 500 N and six swirl type coaxial injectors were used. The passage type manifolds were employed for the injector head to reduce the response time. The passage was designed to minimize stagnation points and recirculation region to ensure uniform flow distribution and sufficient cooling performance through flow analysis using Fluent. A catalytic igniter using hydrogen peroxide was installed at the center of the injector head. The propellant feeding and spray characteristics were confirmed by hydraulic tests. Combustion tests were performed on design and off-design points to analyze combustion characteristics under various mixture ratio conditions. The combustion test results show that combustion efficiency was over 95 % and chamber pressure fluctuation were less than 1.5 % under all test conditions.

Superimposed Propionibacterium Acnes Subdural Empyema in a Patient with Chronic Subdural Hematoma

  • Kim, Jong-Hun;Lee, Chul-Hee;Hwang, Soo-Hyun;Kang, Dong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.53-56
    • /
    • 2009
  • The authors present a case of subdural empyema in a macrocephalic patient. A 23-year-old male was admitted due to headache and fever. One month ago, he had mild head injury by his coworkers. Physical examination showed a macrocephaly and laboratory findings suggested purulent meningitis. Neuroimaging studies revealed a huge size of epidural space-occupying lesion. Under the impression of epidural abscess, operation was performed. Eventually, the lesion was located at subdural space and was proven to be subdural empyema. Later, histological examination of the specimen obtained by surgery demonstrated finings consistent with the capsule of the chronic subdural hematoma. Two weeks after operation, Propionibacterium acnes was isolated. The intravenous antibiotics were used for total of eight weeks under monitoring of the serum level of the C-reactive protein. Follow-up brain computed tomography (CT) scan showed the presence of significant amount of remaining subdural lesion. However, he has complained of minimal discomfort. It is suggested that the subdural empyema occurred with preexisting chronic subdural hematoma after head injury about one month prior to admission and it took a long time to treat Propionibacterium acnes subdural empyema with systemic antibiotics, at least over eight weeks.

Tenants' Post Occupancy Evaluation in the Mid-sized Rental Apartment (중형 임대아파트 거주자의 거주 후 평가)

  • Lee Sang-Un;Park Kyoung-Ok
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.9-18
    • /
    • 2006
  • This study analyzes relevant data based on the mid-sized rental unit. It focuses on how we can set up appropriate mid-sized rental unit plan as its supply has been accelerated over time. The questionnaires used in this study cover a series of categories including site environment, unit plan, neighborhood, economy, and management. The 342 respondents are from the 3-year old apartments at Cheongju. The key findings are as follows. 1) As the average indices including number of family, life cycle, and income under the survey are different in terms of the rental unit sizes between 20 and 30 pyeongs. 2) In general, residents present comparatively high level of satisfaction in terms of residential environments. Their evaluation on the site environment unit plan, and neighborhood is around the average. In contrast, the economic and management efficiency categories are under the average. This study suggests residential guidelines should be derived from tenant differentiation policies dealing with diverse socio-demographic characteristics and satisfaction level. 3) In terms of improvement priority, residents present, higher preference on the management system and site environment. This study advises to establish an appropriate alternative to guarantee effective tenant participation. Considering the lower satisfaction level in the green space, common facilities, and resting space, this study also urges to secure quality control for desirable planning of the mid-sized rental apartments.

Vibrational characteristics of multi-phase nanocomposite reinforced circular/annular system

  • Zhou, Changlin;Zhao, Yi;Zhang, Ji;Fang, Yuan;Habibi, Mostafa
    • Advances in nano research
    • /
    • v.9 no.4
    • /
    • pp.295-307
    • /
    • 2020
  • The vibrational characteristics of Multi-Phase Nanocomposite (MPC) reinforced annular/circular plate under initially stresses are presented using the state-space formulation based on three-dimensional elasticity theory (3D-elasticity theory) and Differential Quadrature Method (DQM). The MPC reinforced annular/circular plate is under initial lateral stress and composed of multilayers with Carbon Nanotubes (CNTs) uniformly dispersed in each layer, but its properties change layer-by-layer along the thickness direction. The State-Space based Differential Quadrature Method (SS-DQM) is presented to examine the frequency behavior of the current structure. Halpin-Tsai equations and fiber micromechanics are used in the hierarchy to predict the bulk material properties of the multi-scale composite. A singular point is investigated for modeling the circular plate. The CNTs are supposed to be randomly oriented and uniformly distributed through the matrix of epoxy resin. Afterward, a parametric study is done to present the effects of various types of sandwich circular/annular plates on frequency characteristics of the MPC reinforced annular/circular plate using 3D-elasticity theory.

Optimal Path Planning for UAVs under Multiple Ground Threats (다수 위협에 대한 무인항공기 최적 경로 계획)

  • Kim, Bu-Seong;Bang, Hyo-Chung;Yu, Chang-Gyeong;Jeong, Eul-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.74-80
    • /
    • 2006
  • This paper addresses the trajectory optimization of Unmanned Aerial Vehicles(UAVs) under multiple ground threats like enemy's anti-air radar sites. The power of radar signal reflected by the vehicle and the flight time are considered in the performance cost to be minimized. The bank angle is regarded as control input for a 1st-order lag vehicle, and input parameter optimization method based on Sequential Quadratic Programming (SQP) is used for trajectory optimization. The proposed path planning method provides more practical trajectories with enhanced survivability than those of Voronoi diagram method.