• Title/Summary/Keyword: Under fault condition

Search Result 222, Processing Time 0.028 seconds

Fault Detection in Linear Descriptor Systems Via Unknown Input PI Observer

  • Hwan Seong kim;Yeu, Tae-Kyeong;Shigeyasy Kawaji
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • This paper deals with a fault detection algorithm for linear descriptor systems via unknown input PI observer. An unknown input PI observer is presented and its realization conditions is proposed by using the rank condition of system matrices. From the characteristics of unknown input PI observer, the states of system with unknown inputs are estimated and the occurrences of fault are detected, and its magnitudes are estimated easily by using integrated output estimation error under the step faults. Finally, a numerical example is given to verify the effectiveness of the proposed fault detection algorithm.

  • PDF

Pattern Recognition of Rotor Fault Signal Using Bidden Markov Model (은닉 마르코프 모형을 이용한 회전체 결함신호의 패턴 인식)

  • Lee, Jong-Min;Kim, Seung-Jong;Hwang, Yo-Ha;Song, Chang-Seop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.11
    • /
    • pp.1864-1872
    • /
    • 2003
  • Hidden Markov Model(HMM) has been widely used in speech recognition, however, its use in machine condition monitoring has been very limited despite its good potential. In this paper, HMM is used to recognize rotor fault pattern. First, we set up rotor kit under unbalance and oil whirl conditions. Time signals of two failure conditions were sampled and translated to auto power spectrums. Using filter bank, feature vectors were calculated from these auto power spectrums. Next, continuous HMM and discrete HMM were trained with scaled forward/backward variables and diagonal covariance matrix. Finally, each HMM was applied to all sampled data to prove fault recognition ability. It was found that HMM has good recognition ability despite of small number of training data set in rotor fault pattern recognition.

A Fault Location Algorithm of a Double-Circuit Line (병행 2회선 송전선로에서의 고장점 표정 알고리즘)

  • Ahn, Yong-Jin;Choi, Myeon-Song;Kang, Sang-Hee;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.255-257
    • /
    • 1999
  • Fault location algorithms based on the current distribution factors under the one-phase to earth fault condition of a double-circuit line are presented. The derivation method for current distribution factors is showed, to calculate fault current, fault resistance and the zero sequence current of other parallel circuit which are unknown. As the proposed algorithms 1,2,3 embodies an accurate location by the voltage and the current of the relaying point.

  • PDF

Dynamic Characteristic and Fault Analysis of the CANDU Nuclear Fuel Channel (CANDU 핵연료 채널에 대한 동특성 및 결함증상 해석)

  • 박진호;이정한;김봉수;박기용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.345-349
    • /
    • 2003
  • The dynamic behavior of CANDU nuclear fuel channel was analyzed by the use of 3-dimensional finite element method, under the various fault conditions such as a fault in the end fitting support and the removal/migration of the garter spring in the fuel channel, in order to predict the dynamic behavior for a degraded symptoms of CANDU nuclear fuel channel. Moreover, the frequency response analysis for possible fault conditions was also peformed considering the effects of the pressure tube vibration and flow-induced vibration by the coolant flow. From the analysis of the frequency responses, defects in the garter spring have influenced the changes of 2nd and 3rd modes and all the important modes are varied for the failure in the journal bearing in the end fitting body.

  • PDF

A Fault Diagnosis Technique of an Inverter-fed PMSM under Winding Shorted Turn and Inverter Switch Open Fault (권선 단락 및 스위치 개방 고장 시의 인버터 구동 영구자석 동기전동기의 고장 진단 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.94-105
    • /
    • 2010
  • To detect faults in an inverter-fed permanent magnet synchronous motor (PMSM) drive under the circumstance having faults in a stator winding and inverter switch, an on-line basis fault detecting scheme during operation is presented. The proposed scheme is achieved by monitoring the second-order harmonic component in q-axis current and the fault is detected by comparing these components with those in normal conditions. The linear interpolation method is employed to determine the harmonic data in normal operating conditions. As soon as the fault is detected, the operating mode is changed to identify a fault type using the phase current waveform. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control algorithm is implemented using DSP TMS320F28335. Without requiring an additional hardware, the fault can be effectively detected by the proposed scheme during operation so long as the steady-state condition is satisfied.

Characteristics on the Transformer-Type SFCL According to Reclosing Operation the Voltage Increase (전압증가 시 재폐로 동작에 따른 변압기형 초전도 한류기의 특성 분석)

  • Choi, Soo-Geun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.477-480
    • /
    • 2010
  • Fault current in power system is expected to increase by demand of power capacity. Therefore, when the fault occurred, fault current was increased in the power system. Many studies have been progressed to limit the fault current. Superconducting fault current limiter (SFCL) is one of them which has been studied in worldwide. In this paper, we will analyze characteristics of a transformer-type SFCL by reclosing operation when the voltage increases. Twice opening times in the reclosing of circuit breaker were set as the 0.5 and 15 seconds, respectively. Turn's number of primary and secondary coils set 4:2 and we increased voltages from 120V to 280V for each experiment. By the current waveform, maximum fault current in second and third cycles was lowered when the voltage was increased. In the recovery waveform, recovery time was increased as the voltage was increased. The reason was that power burden of the SFCL increased when consumption power was increased, so the time to get back to SFCL took longer. We compared the characteristics of a resistive-type and transformer-type SFCL. As a result, we found that the fault current of a transformer-type was lower than resistive-type and recovery time of the SFCL was shorter. Consequently, transformer-type SFCL was more profitable for limitation of fault current and recovery time under the same condition for reclosing operation.

Microstructural Features and K-Ar Ages of Fault Gouges from Quaternary Faults along the Northern Yangsan Fault, SE Korea

  • Chang Oh Choo;Tae Woo Chang;Kounghoon Nam;Jong-Tae Kim;Chang-Ju Lee;Gyo-Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.121-136
    • /
    • 2023
  • Microstructural characterization, identification of mineral assemblages, and K-Ar age dating of fault gouges from five Quaternary fault sites segmented along the northern Yangsan Fault, SE Korea were performed to understand formation condition and multiple activity of faults. The mean and median sizes of particles of bulk gouges vary among the studied faults: 1.75 ㎛ and 1.43 ㎛ for the Danguri Fault, 1.94 ㎛ and 1.79 ㎛ for the Yukjae Fault, 5.57 ㎛ and 4.16 ㎛ for the Yugye Fault, and 5.55 ㎛ and 2.31 ㎛ for the Bogyeongsa Fault. Fault gouges contain abundant secondary minerals, including smectite, chlorite, illite, kaolinite, laumontite, and mordenite, which are found in association with quartz and feldspar. K-Ar dating of the fault gouges (both bulk samples and separate size fractions) yields ages ranging from 59.1 to 18.8 Ma, with bulk ages of 47.6 Ma for the Yukjae Fault, 59.1 Ma for the Ansim Fault, 39.4 Ma for the Yugye Fault, and 22.6 Ma for the Bogyeongsa Fault. The finer fractions generally have younger K-Ar ages compared with the coarser fractions, and the finest fraction (<0.2 ㎛) is the youngest for each fault. Hydrothermal alteration of the gouges is considered to have occurred under low-temperature (100~200℃) conditions during faulting. Microstructural features and clay mineral assemblages of fault gouges and brecciated rocks should be considered when interpreting fault events and reactivation, in addition to age dating of faulting.

Study on Selection of HTS Wire for Fabrication of Fault Current-limiting Type HTS Cables (사고전류 제한형 초전도케이블 제작을 위한 초전도 선재 선정에 관한 연구)

  • Heo, Soung-Ouk;Kim, Tae-Min;Han, Byung-Sung;Du, Ho-Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.12
    • /
    • pp.904-908
    • /
    • 2013
  • When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through a high-capacity and high-$T_c$ superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate measure to protect it. Therefore, appropriate measures are needed to protect HTS cables. The fault-current-limiting HTS cable that was suggested in this study performs an ideal transport current function in normal operations and plays a role in limiting a fault current in abnormal operation (i.e., when a fault current is applied). It has a structure that facilitated its self-current-limiting ability through device change and reconfiguration in the existing HTS cable without extra switching equipment. To complete this structure, it is essential to investigate about the selection of the superconducting wire. Therefore, in this paper, HTS wire using two types of different stabilization layer is compared and examined the stability and current limiting properties under the existence of a fault current.

Dynamic Characteristic of the Superconducting Cable in unbalanced Faults (불평형 고장시의 초전도 케이블의 응동 특성)

  • Lee, Geun-Joon;Lee, Jong-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.37-39
    • /
    • 2007
  • In the faults of power line, single line ground and line-to-line fault make power system to unbalanced. These fault currents make unbalanced power system. This paper suggests the simulation results of dynamic characteristic of HTS cable system under unbalanced faults condition using EMTDC, Quench phenomenon and current limiting effects are observed. However, quench on the HTS is destroy cable system, coordination with SFCL has to be considered.

  • PDF

A Study on the SCADA Simulator (SCADA 시뮬레이터에 관한 연구)

  • Lee, Heung-Jae;Lim, Chang-Ho;Ahn, Bok-Shin;Park, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.936-938
    • /
    • 1997
  • Up to date, operator assistance systems -fault diagnosis system, fault restoration system etc.- are developed for power system automation. In this condition, an efficiency test of assistance system must be performed to prove application in real power system. This paper presents an SCADA simulator for an efficiency test of the operator assistance system, which is developed in the SCADA system. The proposed simulator is implemented under Win95 with Pentium-PC.

  • PDF