• Title/Summary/Keyword: Uncertainty in Measurement

Search Result 854, Processing Time 0.026 seconds

Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient (암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석)

  • Lee, Chang-Hee;Choi, Jung-Eun;Kim, Sun-Ha;Chung, Yong-Sam;Moon, Jong-Hwa;Yoo, Hwa-Seung
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

Structure & Installation Engineering for Offshore Jack-up Rigs

  • Park, Joo-Shin;Ha, Yeong-Su;Jang, Ki-Bok;Radha, Radha
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.39-46
    • /
    • 2017
  • Jack-up drilling rigs are widely used in offshore oil and gas exploration industry. It is originally designed for use in the shallow waters less than 60m of water depth; there is growing demand for their use in deeper water depth over 150m and harsher environmental conditions. In this study, global in-place analysis of jack-up rig leg for North-sea oil well is performed through numerical analysis. Firstly, environmental conditions and seabed characteristics at the North-sea are collected and investigated measurements from survey report. Based on these data, design specifications are established and the overall basic design is performed. Dynamic characteristics of the jack-up rig for North-sea are considered in the global in-place analysis both leg and hull and the basic stability against overturning moment is also analyzed. The structural integrity of the jack-up rig leg/hull is verified through the code checks and the adequate safety margin is observed. The uncertainty in jack-up behaviour is greatly influenced by the uncertainties in the soil characteristics that determine the resistance of the foundation to the forces imposed by the jack-up structure. Among the risks above mentioned, the punch-through during pre-loading is the most frequently encountered foundation problem for jack-up rigs. The objective of this paper is to clarify the detailed structure and installation engineering matters for prove the structural safety of jack-up rigs during operation. With this intention the following items are addressed; - Characteristics of structural behavior considering soil effect against environmental loads - Modes of failure and related pre-loading procedure and parameters - Typical results of structural engineering and verification by actual measurement.

  • PDF

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample (저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.123-131
    • /
    • 2018
  • This study compared PENELOPE with measured values from low energy peak to high energy peak to reduce peak to compton ratio and continuum background spectrum using $^{60}Co$, $^{137}Cs$ and mixed volume source. In addition, the change in backscattering and compton edge efficiency was compared with that of PENELOPE through changes in the vicinity of low energy. The results from the mixed volume source are applied to the soil samples to determine how much the minimum detection limits of the soil samples are reduced in the suppression and unsuppressed mode. The compton suppression of the low energy region of $^{60}CO$ (1,173 keV) was considerable, and the Compton edge RF for the $^{137}Cs$ (661 keV) peak was 2.8. In particular, the $^{60}Co$ source emits coincidence gamma rays of 1,173.2 keV and 1,332.5 keV, so compton inhibition was reduced by approximately 21%. RF of compton edges of 1,173 keV and 1,332 keV emitted from a $^{60}Co$ source was 3.2 and 3.4, and the peak to compton edge ratio was improved to 8: 1. And Compared with Penelope, the uncertainty was well within 2%. In compton unsuppressed mode, MDA values of 661 keV, 1,173 keV and 1,332 keV were 0.535, 0.173 and 0.136 Bq/kg, respectively, but decreased in compton suppressed mode to 0.121, 0.00826 and 0.00728 Bq/kg. Thus, Compton suppressed could reduce the background radioactivity and the radioactivity contained in the detector itself.

A Study on the Factors of SCM Integration Level Influencing SCM and Management Performance : Focused on the Small-Medium Size Enterprises (중소기업의 공급사슬망 통합수준이 SCM 성과 및 경영성과에 미치는 영향에 관한 연구)

  • Sung, Ho-Kyung;Lee, Minho;Boo, Jeman
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.3
    • /
    • pp.167-178
    • /
    • 2020
  • The purpose of this study is to examine the relationship between internal corporate, supplier, and customer integrations for domestic SMEs on non-financial and financial performance through SCM performance such as flexibility and reduction of uncertainties. To this end, data was collected on 286 SMEs in Korea, and the structural relationships between SCM integration level, SCM performances, and management performance were analyzed. As a result of the analysis, first, it was found that the SCM integration level had a significant positive effect on the flexibility and reduction of uncertainties, which are SCM performances. Second, the flexibility and reduction of uncertainties showed significantly positive effects on the non-financial performance of the companies, but did not directly affect the financial performance positively. Third, the non-financial performance was found to have a positive effect on the financial performance. In addition, the SCM integration level did not have a direct effect on the financial and non-financial performance, but it was found that it affected management performance by mediating the flexibility and reduction of uncertainties, which are SCM performances. That is, although the SCM integration level did not directly affect financial and non-financial performance, it was confirmed that it affects management performance by mediating SCM performances, flexibility and uncertainty reduction. In other words, it was confirmed that the SCM integration level directly or indirectly affects SCM performances and overall management performance. These results imply the necessity to focus on competency in the supply chain management area according to the SCM performance expected by SMEs, and the step by step approaches to the expected effects. In a situation where prior SCM related studies have not been able to present SCM performances and management performance of SMEs that are relatively lacking in their capital and SCM construction capabilities, the findings of this study could suggest the importance of SCM integration from the perspective of SMEs. In addition, from the viewpoint of SMEs, this study suggested that a sequential approach for performance measurement is required (SCM performance → management performance) in relation to the performance factors to be established through SCM.

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.

Optimization of $CO_2$ Direct Absorption Method for the Determination of Carbon-14 in Environmental Samples (환경시료중의 방사성탄소 측정을 위한 $CO_2$ 직접흡수법의 최적화 연구)

  • Cho, Soo-Young;Woo, Hyung-Joo;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.237-242
    • /
    • 1998
  • The goal of this work was to optimize the liquid scintillation counting techniques for the determination of C-14 in environmental samples such as biological and air samples. Carbon-14 activities in most environmental samples were measured with direct $CO_2$ absorption method. The highest figure of merit was found through the variation of Carbosorb $E^{TM}$ and Permatluor $V^{TM}$ ratio, in the measurement windows. The best condition was 1:1 volume ratio. Average 2.35 g of $CO_2$ was reproducibly absorbed in the 20 ml mixture within 40 min. The counting efficiency determined by repeated analysis of NIST oxalic acid standard and the background count rate were measured to be $58.8{\pm}1.4%$ and $1.88{\pm}0.06\;cpm$, respectively in case of saturated solution. The correction curves of counting efficiency for partially saturated solutions and for saturated solutions with quenching were prepared, respectively. The overall uncertainty of the sample specific activity for near background levels was estimated to be about 7 % for 4 hours counting at 95 % confidence level. The long-term stability of samples has been checked for all the counting techniques over a two week periods, and no apparent change in counting efficiency and background level was found at that time.

  • PDF

Development of soil certified reference material for determination of the hazardous elements (유해원소 측정용 토양 인증표준물질 개발)

  • Kim, In-Jung;Min, Hyung-Sik;Suh, Jung-Ki;Han, Myung-Sub;Lim, Myung-Chul;Kim, Young-Hee;Shin, Sun-Kyoung;Cho, Kyung-Haeng
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • A certified reference material (CRM) of KRISS 109-03-SSD was developed for the analysis of hazardous elements in soil. The target elements were As, Cd, Cr, Cu, Hg, Ni, Pb, Zn being regulated by the Soil Environment Conservation Act. Starting material was collected from tailing dump of an unworked tungsten mine at Sangdong (Gangwon-do, Korea). The starting material under-went through a series of fabricating process steps of screening, drying, grinding, sieving, blending, bottling, sterilization and was certified according to the ISO Guide 35. Isotope dilution-inductively coupled mass spectrometry (ID-ICP/MS) and instrumental neutron activation analysis (INAA) were used for the measurement. Homogeneity was tested according to ISO 13528 annex B. The certified values were determined using the results from two different methods or from two independent measurements using a method. Finally, certified values of seven elements of arsenic, cadmium, chromium, copper, lead, nickel and zinc were determined. Mercury did not satisfied the criteria of homogeneity and the result would be provided for information only, together with iron and tungsten. It was also studied, the extractable fraction of elements by aqua regia according to the ISO 11466 protocol being frequently studied for the purpose of environmental monitoring. It was performed as a inter-laboratory study by 6 laboratories of a public institute and universities. Standard deviation among the laboratories was much bigger than the uncertainty of the certified value. The result of inter-laboratory study on the extractable fraction will be provided for information, only.

A Study on the Changes in Heavy Metal Emissions when Using Mixed Fuel in a Thermal Power Plant (화력발전소의 혼합연료 사용에 따른 중금속 배출량 변화 연구)

  • Song, Youngho;Kim, Ok;Park, Sanghyun;Lee, Jinheon
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.63-75
    • /
    • 2018
  • Objectives: The aim of this research is to explore the total heavy metals from a coal-fired power plant burning bituminous coal with wood pellets due to the implementation of the Renewable Portfolio Standard policy (RPS, 10% of electricity from renewable energy resources by 2023). Methods: The research was carried out by collecting archival data and using the USEPA's AP-42 & EMEP/EEA compilation of emission factors for use in calculating emissions. The Monte Carlo method was also applied for carrying out the calculations of measurement uncertainty. Results: In this paper, the results are listed as follows. Sb was measured at 110 kg (2015) and calculated as 165 kg (2019) and 201 kg (2023). Cr was measured at 1,597 kg (2015) and calculated as 1,687 kg (2019) and 1,728 kg (2023). Cu was measured at 2,888 kg (2015) and calculated as 3,133 kg (2019) and 3,264 kg (2023). Pb was measured at 2,580 kg (2015) and calculated as 2,831 kg (2019) and 2,969 kg (2023). Mn was measured at 3,011 kg (2015) and calculated as 15,034 kg (2019) and 23,014 kg (2023). Hg was measured at 510 kg (2015) and calculated as 513 kg (2019) and 537 kg (2023). Ni was measured at 1,720 kg (2015) and calculated as 1,895 kg (2019) and 1,991 kg (2023). Zn was measured at 7,054 kg (2015) and calculated as 9,938 kg (2019) and 11,778 kg (2023). Se was measured at 7,988 kg (2015) and calculated as 7,663 kg (2019) and 7,351 kg (2023). Conclusion: This shows that most heavy metals would increase steadily from 2015 to 2023. However, Se would decrease by 7.9%. This analysis was conducted with EMEP/EEA's emission factors due to the limited emission factors in South Korea. Co-firewood pellets in coal-fired power plants cause the emission of heavy metals. For this reason, emission factors at air pollution control facilities would be presented and the replacement of wood pellets would be needed.