• Title/Summary/Keyword: Unbalanced load

Search Result 284, Processing Time 0.033 seconds

Ductility of Column-Slab eoint in R/C Flat Plate System (플랫 플레이트 구조의 기둥.슬래브 접합부 연성에 관한 연구)

  • 김형기;박복만
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.113-119
    • /
    • 2000
  • The R/C flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problems in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab joint. Recently, the flat plate system accompanied with shear walls to resist the lateral loads is applied to high-rise buidings. Although the flat plate system is not considered in design as part of the lateral load-resisting system, it is required that this system keeps the ductile behavior for the lateral displacement of the building. However, it is unclear whether the column-slab joint possesses ductility enough to survive the lateral deformation. The objective of this paper is to investigate the major parameters that influence the ductility of R/C flat plate system by examining the existing experiments on column-slab joint. The effects of gravity load and shear reinforcement on the ductility of the flat plate system are presented.

A Voltage and Frequency Controller for Stand Alone Pico Hydro Generation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.267-274
    • /
    • 2009
  • This paper deals with a voltage and frequency (VF) controller for an isolated power generation system based on an asynchronous generator (AG) driven by a pico hydro turbine. The proposed controller is a combination of a static compensator (STATCOM) and an electronic load controller (ELC) for decoupled control of the reactive and active powers of the AG system to control the voltage and frequency respectively. The proposed generating system along with its VF controller is modeled in MATLAB using SIMULINK and PSB (Power System Block Sets) toolboxes. The performance of the controller is verified for the proposed system and feeding various types of consumer load such as linear/non-linear, balanced/unbalanced and dynamic loads.

Analysis on the Harmonic Characteristics of Nonlinear Load Operated by Unbalance Voltage (불평형 전압으로 운전하는 비선형 부하의 고조파 특성 분석)

  • 김종겸;이은웅;이동주
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.10
    • /
    • pp.491-500
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

Evaluation of Running Stability of Tilting Trains in Conventional Curved Track (틸팅차량의 기존선 곡선부 주행안정성 평가)

  • 엄기영;엄주환;유영화;최정호
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.367-373
    • /
    • 2004
  • The investigation of running stability of the train for curved track is necessary in view of preventing the train from derailment caused by unbalanced forces transferred from the wheel and guaranteeing moderate level of running safety in curve sections. This paper carried out an analysis of running stability of tilting trains in conventional line which the test operation of tilting trains under development are scheduled. For this purpose, the wheel load and lateral pressure to the rail are evaluated. The criteria for the calculated wheel load and derailment coefficient are compared to the design criteria for running stability. It is founded that the running stability of tilting trains for curved track is guaranteed to have sufficient safety and the train speed in curve is governed by the geometric layout of track rather than the criteria for running stability.

A Study on Frequency Simulator Design for Load Following Test of Generator (발전기 부하추종성 시험용 주파수 Simulator 설계에 관한 연구)

  • Kwak, Wol-Hwan;Lee, Gang-Wan;Oh, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.138-142
    • /
    • 2004
  • Recently over dropped frequencies of power system were recorded when power system was unbalanced between generation and demand. Therefore load following characteristic analysis of thermal and combined cycle power plant generators is necessary for low frequency condition analysis of power system. Frequency simulator supplies simulated frequency to the online generator for prescribed goal. This simulator needs to minimize effects to power system and requires stability first. This paper introduces design and manufacturing case of frequency simulator for load following characteristic analysis of generators.

  • PDF

DC Voltage Balancing Control for Multilevel H-Bridge STATCOM (다단 인버터 STATCOM의 직류전압 평형 제어)

  • Kim, Kyoung-Jin;Song, Seong Ho;Jeong, Seung-Gi
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.234-237
    • /
    • 2010
  • This paper proposes a balancing control of DC-link voltages of a H-bridge multilevel inverter for STATCOM application. Individual DC link voltage is controlled by simply adjusting the d-q voltage reference through a PI controller in each cell while the main controller carries out the reactive power control. The correctness and effectiveness of the method are validated by PSIM simulation with unbalanced load condition data taken from a typical arc furnace load, showing the adverse effects of load unbalance to DC link voltage significantly suppressed.

  • PDF

Congestion-Aware Handover in LTE Systems for Load Balancing in Transport Network

  • Marwat, Safdar Nawaz Khan;Meyer, Sven;Weerawardane, Thushara;Goerg, Carmelita
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.761-771
    • /
    • 2014
  • Long-Term Evolution employs a hard handover procedure. To reduce the interruption of data flow, downlink data is forwarded from the serving eNodeB (eNB) to the target eNB during handover. In cellular networks, unbalanced loads may lead to congestion in both the radio network and the backhaul network, resulting in bad end-to-end performance as well as causing unfairness among the users sharing the bottleneck link. This work focuses on congestion in the transport network. Handovers toward less loaded cells can help redistribute the load of the bottleneck link; such a mechanism is known as load balancing. The results show that the introduction of such a handover mechanism into the simulation environment positively influences the system performance. This is because terminals spend more time in the cell; hence, a better reception is offered. The utilization of load balancing can be used to further improve the performance of cellular systems that are experiencing congestion on a bottleneck link due to an uneven load.

Half-Scaled Substructure Test of a Transmission Tower Using Actuators (엑츄에이터를 이용한 송전철탑의 1/2 축소부분실험)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.178-188
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, it was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

  • PDF

A Study on the Characteristics of HTS Cable System Operation and Cooling Load in a Load Unbalance (불평형 부하에서의 초전도케이블 운전 및 냉각부하 특성에 관한 연구)

  • Sohn, S.H.;Lim, J.H.;Yang, H.S.;Choi, H.O.;Ma, Y.H.;Kim, D.L.;Ryoo, H.S.;Ryu, K.W.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.397_398
    • /
    • 2009
  • Demonstrations to deploy high temperature superconducting (HTS) cable to the real gird are actively carried out throughout the world. Power utilities have an interest in the inherent advantage of the HTS cable system, and achieve the expected results from the series of verification test. To embody the reliability in the phenomenon occurred commonly in three-phase system, we simulate the load unbalance. A 22.9 kV large scale HTS cable system with the specification of 100 m-long, 50 MVA capacity has been tested with up to 30% unbalance rate. To evaluate the effect of AC loss increase due to the unbalanced load, the cooling loads are measured by the calorimetry method. In this paper, the correlation between AC loss and load unbalance is described and investigated precisely.

  • PDF

Seismic Design and Deformability of Interior flat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 변형능력과 내진설계방법)

  • 최경규;박홍근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.117-122
    • /
    • 2002
  • Flat Plate structures subjected to lateral load are susceptible to the brittle failure, therefore deformability of plate-column connections should be ensured to resist against earthquake. However, according to previous study, existing experiments overestimate the deformability of connections and current design provision do not accurately explains them. In the present study, parametric study using nonlinear finite element analysis was performed. Based on the numerical results, seismic design method considering the deformability of connections was developed.

  • PDF