• Title/Summary/Keyword: Unbalance distribution system

Search Result 91, Processing Time 0.02 seconds

A Study on Application for Y-Tz Transformer Winding Method to Decrease the Current Unbalance on the Source Side (전원측 전류불평형 감소를 위한 변압기 Y-Tz 결선방식 적용에 관한 연구)

  • Lee, Jung-Eun;Song, Young-Joo;Choi, Hong-Kyoo;Kim, Tae-Hoon;Kim, In-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1206-1211
    • /
    • 2014
  • Most LV customers have been applying three-phase four-wire electric distribution system which supplies 1-phase and 3-phase load concurrently. Due to its structural simplicity, This system is easy to run. But it can also cause many problems from the unbalance, such as reduced output, increased loss etc. Also the unbalance in the load side causes the unbalance in the source side; it may lower the stability of the whole power system. In this paper, we propose the Y-Tz transformer winding method to reduce the current unbalance in the source side. Efficiency of this method was proven through the simulation and verification experiment.

Field Measurement and Analysis of Voltage Unbalance Factor (전압불평형율의 현장측정 및 분석)

  • Jeong, Jong-Ho;Park, Young-Jeen;Lee, Eun-Woong;Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But voltage unbalance more commonly emerges in individual customer loads due to phase load unbalance, especially where, single-phase power loads are used. Voltage unbalance factor(VUF) represents the loss of symmetry in the supply(magnitude and angle). It leads some problems such as de-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with internationally allowable voltage unbalance limits.

The Comparison Study for Voltage, Current and Load Unbalance Factor (전압, 전류 및 부하 불평형율에 대한 비교 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Park, Jong-Ho;Lee, Eun-Wong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.115-120
    • /
    • 2004
  • Most of the LV customer have been applied the distribution system of 3-phase four wire system because of its advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But uneven load distribution or unclean voltage quality has occurred various problems such as do-rating, losses increase and vibration, etc. In this paper, voltage, current and power waveform in the actual fields have measured and analyzed in relation with internationally allowable voltage unbalance limits and compared the current unbalance factor with the load unbalance factor.

  • PDF

A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load (선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

Analysis on the Operation Characteristics of induction motor by asymmetric voltage unbalance (비대칭 전압불평형에 의한 유도전동기의 동작특성 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Jeong, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.110-112
    • /
    • 2003
  • This paper describes a detailed performance of induction motor with asymmetric voltage unbalance generated at the customer distribution system. The simulation results show that the change of current and torque, with the increase of unbalance factor, are more larger and has an important effect on load system.

  • PDF

Analysis on the Harmonics Characteristics Due to Increase & Decrease of Nonlinear Load (비선형 부하의 증감에 따른 고조파 특성 분석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.3
    • /
    • pp.100-106
    • /
    • 2003
  • The increasing application of power electronic equipment in industrial field has led to a growing concern for harmonic distortion and the resulting impacts on system equipment and operations. Harmonic currents are generated by the operation of nonlinear loads and equipment on the power system. These are more increased by unbalance voltage of electrical distribution power systems. This paper describes harmonics characteristics generated by varying of nonlinear load at the PCC under the voltage unbalance.

Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems (부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안)

  • 이유정;김규호;이상근;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.5
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

Analysis on the Operation Characteristics of Induction Motor Operated by Asymmetric Unbalanced Voltage (비대칭 불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • Kim, Jong-Gyeum;Sohn, Hong-Kwan;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.58-64
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance is a condition in a polyphase system in which the rms values of the line-to-line voltages or the phase angles between consecutive line-to-line voltages, are not all equal. Slight voltage unbalance generates a disproportionately high current unbalance at the motor stator winding. This paper presents a scheme on operation states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

Evaluation of Voltage Sag and Unbalance due to the System Connection of Electric Vehicles on Distribution System

  • Lee, Soon-Jeong;Kim, Jun-Hyeok;Kim, Doo-Ung;Go, Hyo-Sang;Kim, Chul-Hwan;Kim, Eung-Sang;Kim, Seul-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.452-460
    • /
    • 2014
  • Due to increased concerns for rising oil prices and environmental problems, various solutions have been proposed for solving energy problems through tightening environmental regulations such as those regarding $CO_2$ reduction. Among them, Electrical Vehicles (EVs) are evaluated to be the most realistic and effective approach. Accordingly, research and development on EVs and charging infrastructures are mainly proceeding in developed countries. Since EVs operate using electric energy form a battery, they must be connected to the power system to charge the battery. If many EVs are connected during a short time, power quality problems can occur such as voltage sag, voltage unbalance and harmonics which are generated from power electronics devices. Therefore, when EVs are charged, it is necessary to analyze the effect of power quality on the distribution system, because EVs will gradually replace gasoline vehicles, and the number of EVs will be increased. In this paper, a battery for EVs and a PWM converter are modeled using an ElectroMagnetic Transient Program (EMTP). The voltage sag and unbalance are evaluated when EVs are connected to the distribution system of the Korea Electric Power Corporation (KEPCO). The simulation results are compared with IEEE standards.