• 제목/요약/키워드: Unbalance conditions

검색결과 122건 처리시간 0.023초

전압불평형의 표현방식에 관한 연구(II) - 전압불평형계수의 근사적 표현방식 - (A Study on the Representation of Voltage Unbalance: Part II-Approximations of Voltage Unbalance Factor)

  • 정승기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.263-270
    • /
    • 2003
  • In field applications, to represent the degree of voltage unbalance, the maximum voltage deviation from the average is preferred to the voltage unbalance factor based on symmetrical component analysis. This paper first clarifies the relationship between the voltage unbalance factor and the maximum deviation factor showing that the maximum deviation factor approximates the voltage unbalance factor under relatively low unbalanced conditions. Several alternative ways of approximation are introduced and examined by comparing with the conventional maximum deviation factor. It appears that these alternatives provide more accurate approximation to the voltage unbalance factor over wider range of voltage unbalance while maintaining simplicity in their formula.

전력 품질 향상을 위한 LVDC 양극성 배전 시스템의 불평형 전압 제어 (Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality)

  • 이희준;신수철;강진욱;원충연
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.486-496
    • /
    • 2016
  • The voltage unbalance of an LVDC bipolar distribution system was controlled for high power quality. Voltage unbalance may occur in a bipolar distribution system depending on the operation of the converter and load usage. Voltage unbalance can damage sensitive load and lead to converter accidents. The conditions that may cause voltage unbalance in a bipolar distribution system are as follows. First, three-level AC/DC converters in bipolar distribution systems can lead to voltage unbalance. Second, bipolar distribution systems can be at risk for voltage unbalance because of load usage. In this paper, the output DC link of a three-level AC/DC converter was analyzed for voltage unbalance, and the bipolar voltage was controlled with algorithms. In the case of additional voltage unbalance according to load usage, the bipolar voltage was controlled using the proposed converter. The proposed converter is a dual half-bridge converter, which was improved from the secondary circuit of a dual half-bridge converter. A control algorithm for bipolar voltage control without additional converters was proposed. The balancing control of the bipolar distribution system with distributed power was verified through experiments.

비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads)

  • 김종겸;박영진;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

자기베어링을 이용한 플라이휠 에너지 저장 시스템의 불평형 질량에 의한 베어링의 동적 부하 용량 (A magnetic bearing capacity due to unbalance mass in a flywheel energy storage system)

  • 김봉수;배용채;이욱륜;김희수;이두영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.176-181
    • /
    • 2009
  • In this article, excitation forces due to unbalance mass in a flywheel energy storage system will be discussed, which mainly consists of a composite flywheel and active magnetic bearings and a motor/generator. Unbalance mass causes moments as well as centrifugal forces to the center of the flywheel when the flywheel rotates. The moment excites the flywheel to revolve in the shape of conical revolution and in real operation, the flywheel shows an aspect that conical revolution is a main mode when system failure occurs. Although there are several excitation sources to the flywheel including unbalance mass, an excitation from motor and control issues of the magnetic bearings, we could infer unbalance mass is the main cause of the failure from a comparison between a composite flywheel and a steel flywheel in the same condition. In this of view, excitation forces and moments induced by unbalance mass should be carefully considered in dynamics of the flywheel so that the energy storage system can be operated in more stable conditions.

  • PDF

전압 불평형율을 이용한 분산전원의 고립운전 검출 기법 (An Islanding Detection Method for Distributed Generations Using the Voltage Unbalance)

  • 장성일;박종근;김황호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.42-44
    • /
    • 2004
  • This paper introduced and proposed the voltage unbalance of DC terminal output as new monitoring parameter for power islanding detection. This paper also presented a simple and novel detection algorithm, which effectively combines the detection results of the conventional parameter, voltage magnitude, and a newly proposed parameter. We tested the proposed method using several distribution network conditions including not only islanding operation conditions, but also non-islanding conditions of normal network load variations. The test results showed that the proposed parameters and algorithm are capable of correctly detecting the islanding operation not affected by variation of DG loading and also have a good selectivity for islanding conditions and non-islanding conditions.

  • PDF

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

Voltage Sag Detection Algorithm for Instantaneous Voltage Sag Corrector

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.162-170
    • /
    • 2002
  • Voltage sag detection algorithm for voltage sag corrector is proposed in this paper. To quantify the standard of voltage unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (UF). It is analyzed that MWF and UF values are given as the dc constant values even though under the voltage unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

다수 캐비티의 사출성형품에서 충전의 불균형과 성형품 치수 편차의 교찰 (Investigation of the Filling Unbalance and Dimensional Variations in Multi-Cavity Injection Molded Parts)

  • 강민아;류민영
    • 폴리머
    • /
    • 제32권6호
    • /
    • pp.501-508
    • /
    • 2008
  • 렌즈나 휴대폰 부품 같은 소형 플라스틱 부품들은 일반적으로 다수 캐비티 사출금형에서 성형된다. 이러한 다수 캐비티 금형에서의 사출성형은 캐비티간의 충전 불균형이 일어날 수 있다. 이러한 충전 불균형 현상은 제품의 치수 및 중량의 편차뿐 아니라 제품의 물리적 특성에도 영향을 미친다. 충전 불균형은 무엇보다도 기하학적으로 균형 잡히지 않은 delivery system의 설계에서 기인된다. 하지만 delivery system이 기하학적으로 균형 있게 설계가 되었다 하더라도 충전 불균형 현상은 여전히 발생된다. 이러한 현상은 런너 단면에서의 온도분포에 기인하며 사출성형 공정 중 사출속도에 크게 영향을 받는 것으로 본 연구에서 파악되었다. 즉 충전 불균형은 부적절한 사출 성형 공정에 의해 발생되며 성형 공정 조건 중 사출속도는 충전에 영향을 주는 매우 중요한 요소이다. 본 연구에서는 재료와 사출 속도에 따른 충전 불균형 현상을 실험과 CAE을 통하여 관찰하였다. 사출속도 변화에 따른 충전 불균형 때문에 시편의 치수 및 무게가 불균일함을 확인하였다.

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

전원전압의 불평형 및 왜곡 보상기능을 갖는 3상 PWM 정류기의 전류제어기 (A Current Controller with the Compensation of the Input Voltage Unbalance and Distortion for Three Phase PWM Rectifier)

  • 신근희;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.594-601
    • /
    • 2011
  • 본 논문은 상용의 전원 전압이 불평형 및 왜곡을 갖는 경우, 전원전압 불평형 및 왜곡 보상기능을 갖는 전류제어기를 제안한다. 일반적으로 3상 전원 시스템은 공통 입력 단자 (Point of Common Coupling)에 단상 부하 및 비선형 부하가 3상 부하와 같이 연결될 수 있어, 종종 불평형과 왜곡이 발생한다. 이런 조건하에서 3상 PWM 정류기를 일반적인 전류 제어기로 제어 할 경우, 3상 PWM 정류기 입력 전류가 불평형 및 왜곡을 갖는 문제가 발생한다. 본 논문에서는 간단한 모델 기반 적응 제어 시스템(Model Reference Adaptive System)기법을 이용하여 3상 입력 전압의 불평형 및 왜곡을 관측하고 전향 보상하는 전류 제어기를 제안하며, 모의해석과 실험을 통하여 그 효용성을 입증한다.