Comparison between Colour Intensity of Tongue Body and That of Tongue Coat under the Ultraviolet Light in RGB system of Peeling Tongue Coat Image (RGB 컬러모델에서 자외선 조명하 박락태(剝落苔)의 설태와 설질 사이의 색 강도 차이에 관한 연구)

  • Nam, Dong-Hyun;Kim, Ji-Hye;Lee, Woo-Beom;Lee, Sang-Suk;Hong, You-Sik
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.149-158
    • /
    • 2011
  • Objectives: The objective of this study is to compare the colour intensity of tongue body and that of tongue coat under the visible light and the ultraviolet light. Methods: We selected 7 subjects with completely or partially peeled tongue coat among the recruited 94 adults for the experiment. We took each tongue picture under the visible light and the ultraviolet light (315-400 nm) and then extracted sample images from the tongue body and tongue coat regions. Mean, median and mode of colour intensity from the sample images were calculated in 256 RGB system. Results: The green and the blue colour intensities of the tongue coats were significantly higher than those of the tongue bodies under the visible light. In all channels, the red, green and blue, the colour intensities of the tongue coats were significantly higher than those of the tongue bodies under the ultraviolet light. The colour differences between tongue coats and tongue bodies under the ultraviolet light were significantly higher than the colour differences under the visible light. Especially the colour difference under the ultraviolet light was highest in the green channel. Conclusions: We suggested that green colour image of the RGB system taken under the ultraviolet light could be used for more easy separating tongue coat region from tongue body.

Photoluminescence Characteristics of Eu-doped YBO3 Phosphor Prepared by Spray Pyrolysis under Vacuum Ultraviolet (분무열분해 공정에 의해 합성된 유로피움이 도핑된 YBO3 형광체의 진공자외선 하에서의 발광 특성)

  • Koo, Hye-Young;Kang, Yun-Chan
    • Korean Journal of Materials Research
    • /
    • v.16 no.8
    • /
    • pp.485-489
    • /
    • 2006
  • The preparation conditions of $YBO_3$:Eu phosphor particles having the maximum photoluminescence intensity under vacuum ultraviolet in the spray pyrolysis were optimized. The $YBO_3$:Eu phosphor particles prepared from spray solution with stoichiometric amount of boric acid had the maximum photoluminescence intensity. The $YBO_3$:Eu phosphor particles with pure phases were formed at low post-treatment temperatures because of fast reaction of yttrium and boron components without volatilization of boron component. The prepared $YBO_3$:Eu phosphor particles by spray pyrolysis had fine size, narrow size distribution and regular morphology. The photoluminescence intensity of the prepared $YBO_3$:Eu phosphor particles under vacuum ultraviolet was 103% of the commercial $(Y,Gd)BO_3$:Eu phosphor particles.

Control of electron concentration and photoluminescence intensity of ZnO thin films using oxygen gas (산소 가스를 이용한 산화아연의 전자 농도와 광발광 세기 조절)

  • Kang, Hong-Seong;Kim, Jae-Won;Lee, Sang-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.185-187
    • /
    • 2004
  • The electron concentration of ZnO thin film fabricated by pulsed laser deposition was controlled by varying oxygen gas pressure. The electron concentration of ZnO was increased from $10^{17}\;to\;10^{19}/cm^3$ as oxygen gas pressure increased from 20 mTorr to 350 mTorr. Ultraviolet(UV) intensity of photoluminescence of ZnO was controlled, too. UV intensity of ZnO was increased as oxygen gas pressure increased from 20 mTorr to 350 mTorr. The relation between electron concentration and UV intensity was investigated.

  • PDF

Characteristics of Phenol Degradation by using UV/TiO2 Photocatalysis (UV/TiO2 광촉매반응에 의한 페놀의 분해 특성)

  • Shin, In-Soo;Choi, Bong-long;Lee, Seung-Mok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.488-493
    • /
    • 2004
  • The effects were examined from several conditions of $TiO_2$ photocatalysis reaction to phenols degradation by changing it's reacting conditions such as phenol concentration, pH, $TiO_2$ concentration, $H_2O_2$ concentration, flow rate, and intensity of ultraviolet rays. Phenol degradation was more efficient in low concentration of phenol, neutral pH. Phenol degradation appeared to increase as concentration of $TiO_2$ photocatalyst, that of $H_2O_2$ and intensity of ultraviolet rays increased. As $TiO_2$ dosage increased, initial rate constant k linearly increased. When $H_2O_2$ was injected more than optimum, phenol removal rate didn't increase in proportional to the change of $H_2O_2$ concentration as OH radicals was being consumed. When flow rate is less than $4.75m^3/m^2$ day, phenol removal efficiency appeared to decrease as ultraviolet rays transmission rate becomes low by $TiO_2$ suspension coated in photo reaction column. Meanwhile, initial rate constant according to light intensity change in less than $25mW/cm^2$ appeared to be in proportion to light intensity ($mW/cm^2$) Removal efficiency decreased about 12% after 180 minutes of reaction time while showed stable removal efficiency of 100% after 300 minutes when using regenerated $TiO_2$.

Distribution of Ultraviolet Intensity and UV Leaking of Commercial UV Sterilizers Used in Restaurants (음식점에서 사용하는 자외선 살균소독기 내 자외선 강도 분포 및 자외선 누출)

  • Mok, Chul-Kyoon;Lee, Nam-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.228-233
    • /
    • 2008
  • Ultraviolet sterilizers (UVS) are widely used in restaurants, cafeterias and catering businesses in Korea. The proper application of UVS, however, is still questionable since no studies have clearly identified their efficacy and safety, while regulations and regulatory management systems are yet to be established. In the present study, the efficacy of UVS were investigated by measuring spatial UV intensity inside five commercially operated UVS. The operating safety parameters were also checked by measuring leaked UV intensity. The UV intensities were inversely proportional to distance from the UV lamp within 25 cm, and to the square of the distance exceeding 25 cm. The UV intensities in commercial UVS varied with the distance from UV lamp and the incident angle, highlighting efficacy and stability concerns. Notable leakage was detected through the door gaps of a studied UVS, which also brought about safety concerns. Allowable working distances for the UV leaking UVS were suggested based on international standards.

Optimization of VUV Characteristics of M3MgSi2O8:Eu2+ (M=Ca, Sr, Ba) Phosphor by Spray Pyrolysis (분무열분해법을 이용하여 M3MgSi2O8:Eu2+ (M=Ca, Sr, Ba) 형광체 분말의 VUV 특성 최적화)

  • Jung, You-Ri;Jung, Kyeong-Youl
    • Journal of Powder Materials
    • /
    • v.15 no.5
    • /
    • pp.399-404
    • /
    • 2008
  • Spray pyrolysis was applied to prepare $M_{3}MgSi_{2}O_{8}:Eu^{2+}$ (M=Ca, Sr, Ba) blue phosphor powder. The library of a Ca-Sr-Ba ternary system was obtained by a combinatorial method combined with the spray pyrolysis in order to optimize the luminescent property under vacuum ultraviolet (VUV) excitation. 10 potential compositions were chosen from the first screening. The emission shifted to longer wavelength as Ca became a dominant element and the emission intensity was greatly reduced in the composition region at which Ba is dominant element. On the base of the first screening result, the second fine tuning was carried out in order to optimize the luminescence intensity under VUV excitation. The optimal composition for the highest luminescence intensity was $(Ca_{1.7},\;Sr_{0.3},\;Ba_{1.0})Si_{2}O_{8}:Eu^{2+}$ which had the color coordinate of (0.152, 0.072) and about 64% emission intensity of $BaMgAl_{10}O_{17}$ (BAM) phosphor.

A Novel Ultraviolet Sensor using Photoluminescent Porous Silicon (광 루미네슨스 다공질 실리콘을 이용한 새로운 자외선 센서)

  • Min, Nam-Gi;Go, Ju-Yeol;Gang, Cheol-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.444-449
    • /
    • 2001
  • In this paper, a novel ultraviolet sensor is presented based on a photoluminescent porous silicon. Porous silicon layer was formed by chemical etching of surface of pn junction in a $HF(48%)-HNO_3(60%)-H_20$ solution. Incident ultraviolet(UV) light is converted to visible light by photoluminescent porous silicon layer, and then this visible light generates electron-hole pairs in the pn junction, which produces a photocurrent flow through the device. In order to maximize detection efficiency, the peak sensitivity wavelength of the pn junction diode was matched with the peak wavelength of Photoluminescence from porous silicon layer. The porous silicon ultraviolet sensor showed a large output current as UV intensity increases and but very low sensitivity to visible light. The detection sensitivity of porous silicon sensor was calculated as 2.91mA/mW. These results are expected to open up a possibility that the present porous silicon sensor can be used for detecting UV light in a visible background, compared to silicon UV detectors which have an undesirable response to visible light.

  • PDF

The Effect of Pulsed Ultrasound on Skin Inflammatory Reaction Induced by Ultraviolet Irradiation (자외선 조사로 유발된 피부 염증성 반응에 맥동성 초음파가 미치는 영향)

  • Lee, Jeong-Woo;Park, Su-Ji;Yoon, Se-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.4
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: This study aims to examine the effects of pulsed ultrasound on skin inflammatory reaction induced by ultraviolet irradiation. Methods: Twenty subjects were selected for this study. Inflammatory reaction was induced by ultraviolet irradiation in two areas of the lumbar region of the subjects. Pulsed ultrasound (3 MHz) was applied to one of the two areas of inflammatory reaction at a pulse ratio of 1:4, intensity of $0.5W/cm^2$, once a day for 5 min, and pulsed ultrasound was not applied to the other area. Wound color (chromatic red), luminance (gray) and wound contraction (area) were measured using digital imaging processing method. Results: There was a significant difference in wound color (chromatic red) in the interaction between time and area. There was a significant difference in luminance in the interaction between time and area. There was a significant difference in wound contraction between the two areas. Conclusion: These results indicate that pulsed ultrasound increased the wound contraction rate and reduced the inflammatory reaction activity such as erythema induced by ultraviolet irradiation.

Measurement of EUV (Extreme Ultraviolet) and electron temperature in a hypocycloidal pinch device for EUV lithography

  • Lee, Sung-Hee;Hong, Young-June;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.108-108
    • /
    • 2010
  • We have generated Ne-Xe plasma in dense plasma focus device with hypocycloidal pinch for extreme ultraviolet (EUV) lithography and investigated an electron temperature. We have applied an input voltage 4.5 kV to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ne-Xe(30%) gas in accordance with pressure. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium (LTE) conditions, the electron temperature of the hypocycloidal pinch plasma focus could be obtained by the optical emission spectroscopy (OES). The electron temperature has been measured by Boltzmann plot. The light intensity is proportion to the Bolzman factor. We have been measured the electron temperature by observation of relative Ne-Xe intensity. The EUV emission signal whose wavelength is about 6~16 nm has been detected by using a photo-detector (AXUV-100 Zr/C, IRD) and the line intensity has been detected by using a HR4000CG Composite-grating Spectrometer.

  • PDF

Effect of Ultraviolet Irradiation on Molecular Properties of Ovalbumin (자외선 조사가 Ovalbumin의 분자적 성질에 미치는 영향)

  • Cho, Yong-Sik;Song, Kyung-Bin;Yamada, Koji;Han, Gui-Jung
    • Applied Biological Chemistry
    • /
    • v.51 no.4
    • /
    • pp.276-280
    • /
    • 2008
  • To elucidate the effects of ultraviolet (UV) irradiation on molecular properties of ovalbumin, the molecular weight profile, secondary structure and tertiary structure of proteins were examined after irradiation by UV with 254 nm wavelength for 4, 8, 16 and 32 hrs, respectively. UV irradiation of protein solution caused the disruption on the native state of protein molecules. SDS-PAGE and gel permeation chromatography indicated that radiation caused initial fragmentation of polypeptide chains and as a result subsequent aggregation due to cross-linking of protein molecules. Circular dichroism (CD) study showed that UV irradiation caused the change on the secondary structure resulting in decrease of helical structure or compact denature on structure of protein depending on irradiation period. Fluorescence spectroscopy indicated that irradiation quenched the emission intensity excited at 280 nm. These results suggest that UV irradiation affect the molecular properties of ovalbumin and may have potential as a means to change the antigenicity of protein allergen.