• 제목/요약/키워드: Ultraviolet flame detector

검색결과 10건 처리시간 0.024초

자외선 센서를 이용한 화재감지기 응용 회로 설계 (Circuit Design of Ultraviolet Flame-Sensor for Fire-Fighting Appliances)

  • 김영민;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we proposed that when combustible burn with ultraviolet radiation, introduce fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame. This research using ultraviolet flame sensor is pyro-electric ultraviolet sensor based black body radiation theory. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV flame detector and proposed method of false alarm reduced to resemble fire. the result proposed the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

자외선/적외선 불꽃감지기 소개 및 오동작 방지를 위한 연구 (Introduction of Ultraviolet/Infrared Flame Detector and Method for False Detection Prevention)

  • 임병현;고낙용;황종선;김영민;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.8-11
    • /
    • 2003
  • We propose that when combustible burn with contain carbon, introduce fire detector with sensor of private-use detectable light energy as infrared and ultraviolet in energy of electromagnetic-wave type radiate from flame, method for correct discrimination to resemble fire produce false alarm of detector such as sun light, hot object radiation, are welding. This research using infrared sensor is pyroelectric infrared sensor based black body radiation theory. Ultraviolet sensor is uv Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV/IR compound type flame detector and proposed method of false alarm reduced to resemble fire. The result propres the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

PWM을 이용한 화재 감지를 위한 자외선 센서의 구동 방법 (Driving Method of Ultraviolet Sensor for Fire alarms using Pulse Width Modulation)

  • 임병현;고낙용;황종선;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집
    • /
    • pp.31-35
    • /
    • 2004
  • We propose driving method of Ultraviolet sensor for fire alarms using pulse width modulation that used to fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame, when combustible burn with contain carbon,. Ultraviolet sensor is UV Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research designed driving circuit with UV sensors and proposed method of false alarm reduced to resemble fire. the result propers the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

UV 화염감지기의 감지성능에 대한 분진분위기의 영향 (Influence of Dust Environment on the Detection Capability of Ultraviolet Flame Detector)

  • 김홍;호예
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.113-119
    • /
    • 1997
  • UV 화염감기의 분진분위기에서의 성능저하를 고찰하기 위하여 세제분말, 탄진 및 분말 소화약제의 분진운을 형성하였고 LPG 및 가솔린 화염을 사용하여 UV 화염감지기의 감지성능을 고찰하였다. 분진 분위기 하에서의 UV 화염감지기의 성능을 분진의 농도와 분진층의 거리가 증가함에 따라 뚜렷한 증가를 보였으며, 분진의 화학적, 물리적 특성에 커다란 영향을 받았다. 따라서 UV 화염감지기를 분진 분위기에서 사용한 경우 특별한 주의를 기울일 필요가 있는 것으로 사려된다.

  • PDF

화염감지기에 대한 고찰

  • 이복영
    • 방재기술
    • /
    • 통권13호
    • /
    • pp.18-26
    • /
    • 1992
  • This report is explained about operating principles, characteristices of flame detectors. Flame detector is designed to detect the UV (Ultraviolet) and IR (Infrared) rediation produced by flaming involving carbonaceous materials.

  • PDF

용액 공정 기반 NiO/ZnO계 자외선 센서용 재료 특성 연구 (A Study on the Material Characteristics of the NiO/ZnO Ultraviolet Sensor Based on Solution Process)

  • 문성철;이지선;노경재;양성주;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제30권8호
    • /
    • pp.508-513
    • /
    • 2017
  • Ultraviolet (UV) photodetectors are used in various industries and fields of research, including optical communication, flame sensing, missile plume detection, astronomical studies, biological sensors, and environmental research. However, general UV detectors that employ Schottky junction diodes and p-n junctions have high fabrication cost and low quantum efficiency. In this study, we investigated the characteristics of materials used to manufacture UV photodetectors in a low-cost solution process that requires easy fabrication of flexible substrates. We fabricated p-type NiO and n-type ZnO substrates with wide band gap by the sol-gel method and compared the characteristics of substrates prepared under different spin-coating and heat-treatment conditions.

도로터널용 방수노즐 위치제어형 자동소화설비의 화재감지성능실험 (Fire Detection Performance Experiment of the Water Jet Nozzle Position Control Type Automatic Fire Extinguishing Facility for Road Tunnels)

  • 김창용;공하성
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.85-91
    • /
    • 2019
  • 이 연구는 불꽃파장 감지기술과 불꽃영상 감지기술을 융합한 도로터널용 자동소화설비의 화재감지성능을 평가하기 위한 실험이다. 화재감지성능을 향상시키기 위한 이 융합기술은 화재 시 화원의 위치를 파악하고, 노즐을 화원으로 향하여 화재가 발생한 장소에만 가압수를 방사함으로서 화재진압에 따른 수손피해를 줄이는 효과를 얻을 수 있었다. 도로터널의 화재 중 불꽃 및 연기가 선행되는 상황에서 각각 15 m, 20 m, 25 m, 30 m, 35 m 거리에 $70cm{\times}70cm$의 목표물을 두었을 때 화원의 위치를 파악하는지를 실험하였다. 실험결과 농연의 간섭으로 인해 자외선 및 삼파장적외선센서의 감지능력이 감쇠되는 결과를 확인하였다. 또한 농연으로 인해 불꽃이 가려진 경우 이미지센서가 농연을 감지하여 화재신호를 발신함을 확인하였다.

Purity assignment of 17β-estradiol by mass balance method

  • Lee, Hwa-Shim;Oh, Kwang-Hoon
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.226-233
    • /
    • 2017
  • In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.

염화비닐 노출 근로자의 요중 Malondialdehyde 농도 수준 (The level of urinary malondialdehyde concentrations in vinyl chloride monomer exposure workers)

  • 김현수;김치년;원종욱;박준호;김광숙;안미현;노재훈
    • 한국산업보건학회지
    • /
    • 제17권2호
    • /
    • pp.81-88
    • /
    • 2007
  • The aim of this study was to investigate whether the exposure to vinyl chloride monomer(VCM) induces lipid peroxidation in workers by evaluating the concentration of malondialdehyde(MDA) in the urine in order to assess worker's oxidative stress due to exposure of vinyl chloride monomer. The subjects investigated in the study were divided into the experimental group; 18 workers exposed to VCM, and the control group; 19 workers unexposed to VCM. A gas chromatography/pulsed flame photometric detector(GC/PFPD) was utilized to analyze thiodiglycolic acid(TDGA), which was methylated with trimethylsilyldiazomethane (2.0M in diethyl ether) in urine and the urinary MDA, the product of lipid peroxidation, was determined by high-performance liquid chromatography/ultraviolet-visible detector after derivatized with 2,4-dinitrophenylhydrazine(DNPH). The concentrations of urinary TDGA in controls and VCM exposure workers were 0.13(2.01)mg/g Cr. GM(GSD) and 0.35(1.96)mg/gCr. GM(GSD), respectively. The concentrations of urinary MDA were $0.12(2.21){\mu}mol/gCr$. GM(GSD) in controls and $1.35(1.79){\mu}mol/gCr$. GM(GSD) in VCM exposure workers. As a result of simple regressions analysis between urinary concentration of TDGA and MDA in VCM exposure workers, it was found that the $R^2$ value was 0.261 (p=0.03) and the drinking and smoking did not affect their level. In conclusion, the workers exposed to VCM have a potentially to suffered by oxidative stress due to VCM exposure and the urinary MDA can be applicable to the marker of effect to assess the level of worker's VCM exposure.

톨루엔 폭로근로자의 혈장중 마뇨산과 공기중 톨루엔과의 상관관계 (The Relationship Between Hippuric Acid in Blood Plasma and Toluene Concentration in the Air of Workplace)

  • 황천현;이원진;장성훈;김형아
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2000
  • Objectives : This study was undertaken to evaluate correlation between the levels of hippuric acid in blood plasma (HAP) and those of toluene concentration in the workplace air. Methods : Study subjects were composed of two groups; 21 workers who were occupationally exposed to toluene and 25 rural-area residents who were not exposed to any known occupational toluene source, as an exposed group and a reference group, respectively. Mean age and work duration of the exposed was 42 years and five years, respectively. Mean age of the reference was 42 years. To determine toluene concentrations in the workplace air, air sampling has been conducted for more than six hours using a personal sampler, and analyzed by a gas chromatography-flame ionization detector. Concentrations of hippuric acid in biological samples were determined by a high performance liquid chromatography-ultraviolet detector. Results : Geometric mean(geometric standard deviation) of HAP and hippuric acid in urine(HAU) for the exposed was 1.39(2.21) mg/L and 2.77(1.46) g/L, respectively, which were significantly different from those of the reference [HAP, 9.45(2.94); HAU, 0.37(0.45)]. Teluene concentration in the workplace air was 86.92(range: $45.18\sim151.23$)ppm. The level of HAP or HAU was significantly correlated (r=0.70 and r=0.63, respectively) with that of toluene in the workplace air. The estimated regression equation was logHAP(mg/L)=-3.60+1.93 log(toluene, ppm) or logHAU(g/L)=-0.85+0.67 log(toluene, ppm). The magnitude of correlation was further enhanced when analyzing relationship between toluene concentrations lower than 100 ppm and its corresponding HAP levels. Conclusion : Overall, plasma hippuric acid levels were well correlated with toluene concentrations in the workplace air, and a statistically significant correlation was observed for the samples with toluene concentration lower than 100 ppm.

  • PDF