• Title/Summary/Keyword: Ultrasound-monitored

Search Result 29, Processing Time 0.024 seconds

Surgical Resuscitation of a Patient with Cerebral Herniation Secondary to Massive Hemorrhage in the Basal Ganglia: Ultrasound-monitored Aspiration

  • Jung, Youn-Ho;Park, Jae-Chan;Hamm, In-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.4
    • /
    • pp.300-302
    • /
    • 2005
  • The authors report a case of hyperacute, massive hemorrhage in the left basal ganglia with severe midline shift that was treated successfully by the ultrasound-monitored free hand aspiration technique. Every effort was made to shorten time until removal of considerable amount of the hematoma and minimize duration of cerebral herniation, avoiding additional irreversible neurological deficit. A burr hole aspiration technique was preferred to standard craniotomy procedure, and any time-consuming procedures such as stereotactic frame application were abandoned. A burr hole was localized on the basis of computed tomography images simply and quickly with a ruler, and safety of the aspiration procedure was augmented by real-time ultrasound monitoring. Such minimally invasive technique relieved cerebral herniation successfully while avoiding time consumption and the morbidity of major craniotomy procedure. Early resuscitation of the patient with cerebral herniation in this case resulted in excellent recovery of the patient's neurological deficit. The patient's mentality started to improve rapidly and was clear six months after the surgery.

A Welding Defect Inspection using an Ultrasound Excited Thermography (초음파 서모그라피를 이용한 용접 결함 검사)

  • Jo Jae-Wan;Jeong Jin-Man;Choi Yeong-Su;Jeong Seung-Ho;Jeong Hyeon-Gyu
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.148-150
    • /
    • 2006
  • In this paper, the applicability of an UET(ultrasound excited thermography) for a defect detection of the welded receptacle is described. An UET(ultrasound excited thermography) is a defect-selective and fast imaging tool for damage detection. A high power ultrasound-excited vibration energy with pulse durations of 280ms is injected into the outer surface of the welded receptacle made of Al material. An ultrasound vibration energy sent into the welded receptacle propagate inside the sample until they are converted into the heat in the vicinity of the defect. The injection of the ultrasound excited vibration energy results in heat generation so that the defect is turned into a local thermal wave transmitter. Its local heat emission is monitored by the thermal infrared camera. And they are processed by the image recording system. Measurement was performed on aluminum receptacle welded by using Nd:YAG laser. The observed thermal image revealed two area of defects along the welded seam.

  • PDF

Finite Element Analysis of Laser-Generated Ultrasound for Characterizing Surface-Breaking Cracks

  • Jeong Hyun Jo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1116-1122
    • /
    • 2005
  • A finite element method was used to simulate the wave propagation of laser-generated ultrasound and its interaction with surface breaking cracks in an elastic material. Thermoelastic laser line source on the material surface was approximated as a shear dipole and loaded as nodal forces in the plane-strain finite element (FE) model. The shear dipole- FE model was tested for the generation of ultrasound on the surface with no defect. The model was found to generate the Rayleigh surface wave. The model was then extended to examine the interaction of laser generated ultrasound with surface-breaking cracks of various depths. The crack-scattered waves were monitored to size the crack depth. The proposed model clearly reproduced the experimentally observed features that can be used to characterize the presence of surface-breaking cracks.

Microfluidic Device for Ultrasound Image Analysis based on 3D Printing (초음파 영상 분석을 위한 3D 프린팅 기반 미세유체소자)

  • Kang, Dongkuk;Hong, Hyeonji;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • For the measurement of biophysical properties related with cardiovascular diseases (CVD), various microfluidic devices were proposed. However, many devices were monitored by optical equipment. Ultrasound measurement to quantify the biophysical properties can provide new insights to understand the cardiovascular diseases. This study aims to check feasibility of microfluidic device for ultrasound image analysis based on 3D printer. To facilitate acoustic transmission, agarose solution is poured around 3D mold connected with holes of the acrylic box. By applying speckle image velocimetry(SIV) technique, flow information in the bifurcated channel was estimated. Considering that ultrasound signal amplitude is determined by red blood cell (RBC) aggregation, RBC aggregation in the bifurcated channel can be estimated through the analysis of ultrasound signal. As examples of microfluidic device which mimic the CVD model, velocity fields in microfluidic devices with stenosis and aneurysm were introduced.

Ultrasound and clinical findings in the metacarpophalangeal joint assessment of show jumping horses in training

  • Yamada, Ana Lucia M.;Pinheiro, Marcelo;Marsiglia, Marilia F.;Hagen, Stefano Carlo F.;Baccarin, Raquel Yvonne A.;da Silva, Luis Claudio L.C.
    • Journal of Veterinary Science
    • /
    • v.21 no.3
    • /
    • pp.21.1-21.14
    • /
    • 2020
  • Background: Physical exercise is known to cause significant joint changes. Thus, monitoring joint behavior of athletic horses is essential in early disorders recognition, allowing the proper management. Objectives: The aims of this study were to determine the morphological patterns, physical examination characteristics and ultrasound findings of show jumping horses in training and to establish a score-based examination model for physical and ultrasound follow-ups of metacarpophalangeal joint changes in these animals. Methods: A total of 52 metacarpophalangeal joints from 26 horses who were initially in the taming stage were evaluated, and the horses' athletic progression was monitored. The horses were evaluated by a physical examination and by B-mode and Doppler-mode ultrasound examinations, starting at time zero (T0), which occurred concomitantly with the beginning of training, and every 3 months thereafter for a follow-up period of 18 months. Results: The standardized examination model revealed an increase in the maximum joint flexion angles and higher scores on the physical and ultrasound examinations after scoring was performed by predefined assessment tools, especially between 3 and 6 months of evaluation, which was immediately after the horses started more intense training. The lameness score and the ultrasound examination score were slightly higher at the end of the study. Conclusions: The observed results were probably caused by the implementation of a training regimen and joint adaptation to physical conditioning. The joints most likely undergo a pre-osteoarthritic period due to work overload, which can manifest in a consistent or adaptive manner, as observed during this study. Thus, continuous monitoring of young athlete horses by physical and ultrasound examinations that can be scored is essential.

Endoscopic ultrasound-guided hepaticogastrostomy by puncturing both B2 and B3: a single center experience

  • Moaz Elshair;Kazuo Hara;Nozomi Okuno;Shin Haba;Takamichi Kuwahara;Asmaa Bakr;Abdou Elshafei;Mohamed Z. Abu-Amer
    • Clinical Endoscopy
    • /
    • v.57 no.4
    • /
    • pp.542-546
    • /
    • 2024
  • Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) through ducts B2 or B3 is effective in most patients with biliary obstruction, because B2 and B3 commonly join together. However, in some patients, B2 and B3 do not join each other due to invasive hilar tumors; therefore, single-route drainage is insufficient. Here, we investigated the feasibility and efficacy of EUS-HGS through both B2 and B3 simultaneously in seven patients. We decided to perform EUS-HGS through both B2 and B3 to achieve adequate biliary drainage because these two ducts were separate from each other. Here, we report a 100% technical and overall clinical success rate. Early adverse effects were closely monitored. Minimal bleeding was reported in one patient (1/7) and mild peritonitis in one patient (1/7). None of the patients experienced stent dysfunction, fever, or bile leakage after the procedure. EUS-HGS through both B2 and B3 simultaneously is safe, feasible, and effective for biliary drainage in patients with separated ducts.

Ultrasonography for long-term evaluation of hyaluronic acid filler in the face: A technical report of 180 days of follow-up

  • Rocha, Luiz Paulo Carvalho;Rocha, Tania de Carvalho;Rocha, Stephanie de Cassia Carvalho;Henrique, Patricia Valeria;Manzi, Flavio Ricardo;Silva, Micena Roberta Miranda Alves e
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.175-180
    • /
    • 2020
  • Purpose: In this study, we used ultrasonography to monitor the use of hyaluronic acid (HA) as a filler in the face for esthetic reasons. We monitored changes in the filler shape, distribution, and relationship with adjacent anatomical structures over a 180-day period. Materials and Methods: Two patients each received an ultrasound-guided injection of HA, with different products and application sites for each patient. In 1 patient, the injection was administered in the angle of the mandible, while in the other, it was administered in the zygomatic region. The injection sites were monitored via ultrasonography at 24 hours, 30 days, and 180 days, at which times the imaging characteristics of the filler were observed. All injections were performed by the same professional, as were the ultrasound exams, which were conducted using the same equipment. Results: In both cases, the HA fillers were visualized using ultrasound at all time points. Some differences were observed between the cases in the images and the distribution of the pockets of filler. In 1 case, the filler appeared as a dark hypoechoic region with well-defined contours, and the material was observed to have moved posteriorly by the 180-day mark. In the other case, the material appeared hyperechoic relative to the previous case and presented no noticeable changes in its anteroposterior distribution over time. Conclusion: Based on these 2 cases, ultrasonography can be a complementary tool used to monitor facial fillers over the long term, allowing for the dynamic observation of different fillers.

Ultrasound-Guided Radiofrequency Ablation in Tertiary Hyperparathyroidism: A Prospective Study

  • Erya Deng;Tingting Jiang;Huihui Chai;Ning Weng;Hongfeng He;Zhengxian Zhang;Chengzhong Peng;Wenwen Yue;Huixiong Xu
    • Korean Journal of Radiology
    • /
    • v.25 no.3
    • /
    • pp.289-300
    • /
    • 2024
  • Objective: To prospectively evaluate the outcomes of ultrasound (US)-guided radiofrequency ablation (RFA) in tertiary hyperparathyroidism (THPT). Materials and Methods: Patients with THPT underwent RFA between September 2017 and January 2022. Laboratory parameters, including serum intact parathyroid hormone (iPTH) levels, were monitored for 48 months after RFA and compared with the levels at baseline. Complications related to RFA and changes in hyperparathyroidism-related clinical symptoms were recorded before and after RFA. Results: A total of 42 patients with THPT were recruited for this study. Ultimately, 36 patients with renal failure and 2 patients who underwent successful renal transplantation (male:female, 17:21; median age, 54.5 years) were enrolled. The follow-up time was 21.5 ± 19.0 months in the 36 patients with renal failure. In these 36 patients, iPTH levels were significantly decreased to 261.1 pg/mL at 48 months compared with the baseline value of 1284.9 pg/mL (P = 0.012). Persistent hyperparathyroidism, defined as iPTH levels maintained at > 585.0 pg/mL for 6 months after treatment, occurred in 4.0% of patients (1/25). Recurrent hyperparathyroidism, defined as iPTH levels > 585.0 pg/mL after 6 months, were 4.0% (1/25) and 0.0% (0/9) at 6 months and 4 years after treatment, respectively. In two patients with THPT after successful renal transplantation, iPTH decreased from the baseline value of 242.5 and 115.9 pg/mL to 171.0 and 62.0 pg/mL at 6 months after treatment. All complications resolved within 6 months of ablation without medical intervention, except in 10.5% (4/38) patients with permanent hypocalcemia. The overall symptom recovery rate was 58.8% (10/17). The severity scores for bone pain, arthralgia, and itchy skin associated with hyperparathyroidism improved after treatment (P < 0.05). Conclusion: US-guided RFA is an effective and safe alternative to surgery in the treatment of patients with TPTH and improves hyperparathyroidism-related clinical symptoms.

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography (초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.4 s.287
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

The Potential Usefulness of Magnetic Resonance Guided Focused Ultrasound for Obsessive Compulsive Disorders

  • Jung, Hyun Ho;Chang, Won Seok;Kim, Se Joo;Kim, Chan-Hyung;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.427-433
    • /
    • 2018
  • Obsessive compulsive disorder is a debilitating condition characterized by recurrent obsessive thoughts and compulsive reactions. A great portion of the obsessive compulsive disorder (OCD) patients are managed successfully with psychiatric treatment such as selective serotonin-reuptake inhibitor and cognitive behavioral psychotherapy, but more than 10% of patients are remained as non-responder who needs neurosurgical treatments. These patients are potential candidates for the neurosurgical management. There had been various kind of operation, lesioning such as leucotomy or cingulotomy or capsulotomy or limbic leucotomy, and with advent of stereotaxic approach and technical advances, deep brain stimulation was more chosen by neurosurgeon due to its characteristic of reversibility and adjustability. Gamma knife radiosurgery are also applied to make lesion targeting based on magnetic resonance (MR) imaging, but the complication of adverse radiation effect is not predictable. In the neurosurgical field, MR guided focused ultrasound has advantage of less invasiveness, real-time monitored procedure which is now growing to attempt to apply for various brain disorder. In this review, the neurosurgical treatment modalities for the treatment of OCD will be briefly reviewed and the current state of MR guided focused ultrasound for OCD will be suggested.