• Title/Summary/Keyword: Ultrasound transducer

Search Result 196, Processing Time 0.022 seconds

Sonochemical Oxidation Reactions in 300 kHz Sonoreactor for Various Liquid Height/Volume Conditions (다양한 액상 수위/부피 조건에서의 300kHz 초음파 캐비테이션 산화반응 분석 연구)

  • Lee, Seongeun;Son, Younggyu
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.5
    • /
    • pp.211-219
    • /
    • 2022
  • In this study, the effect of liquid height/volume on sonochemical oxidation reactions was investigated in 300 kHz sonoreactors. The gas mixture of Ar/O2 (50:50) was applied in two modes including saturation and sparging, and zero-order reaction (KI dosimetry) and first-order reaction (Bisphenol A (BPA) degradation) were used to quantitatively analyze sonochemical oxidation reactions. For the zero-order reaction, the highest sonochemical oxidation activity was obtained for the liquid height of 5𝛌, and the lowest height for both the gas saturation and sparging conditions. In addition, the sparging did not enhance the sonochemical oxidation activity for all height conditions except for 50𝛌, where very low activity was obtained. It was found that in sonochemiluminescence (SCL) images the sonochemical active zone was formed adjacent to the liquid surface for the gas sparging condition due to the formation of the standing wave field while the active zone was formed adjacent to the transducer at the bottom due to the blockage of ultrasound. For the first-order reaction, the highest activity was also obtained at 5𝛌 and the comparison based on the reactant mass was not appropriate because the concentration of the reactant (BPA) decreased significantly as the reaction time elapsed. Consequently, it was revealed that the determination of optimal liquid height (ultrasound irradiation distance) based on the wavelength of the applied ultrasound frequency was very important for the optimal design of sonoreactors in terms of reaction efficiency and reactor size.

Transabdominal Ultrasound Assessment of the Polycystic Ovary Syndrome (다낭난소증후군 진단시 복식 초음파의 유용성에 관한 연구)

  • Jeong, Kyung-Ah;Lee, Woon-Jeong;Chung, Hye-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • Objective: The objective of the study was to determine the diagnostic performance of transabdominal ultrasound by receiver operating characteristic (ROC) curve analysis, in order to evaluate the usefulness in establishing the diagnosis of polycystic ovary syndrome (PCOS). Methods: Questionnaires were given to 8,793 reproductive women reviewed at Ewha Womans University Mokdong hospital. Ultrasound examinations were performed in 701 women with a transabdominal transducer. Transabdominal ultrasounds were performed in 185 normal control women (normal menstruation without hyperandrogenism or PCO morphology) and 248 PCOS patients according to National Institutes of Health (NIH) PCOS diagnosis criteria. ROC curves were calculated for ovarian volume and follicle number. Results: In normal control group, the mean age were $23.64{\pm}4.26$ years old and the mean ovarian volume and follicle number were $6.03{\pm}1.89\;cm^3$ and $6.49{\pm}1.93$, respectively. The ovarian volume showed an area under the ROC curve (AURC) of 0.761. A ovarian volume decision threshold >$9\;cm^3$ had a sensitivity of 51.0% and a specificity of 91.4% for the diagnosis of PCOS. The follicle number showed an AURC of 0.733. A follicle number decision threshold ${\geq}9$ had a sensitivity of 54.9% and a specificity of 87.0% for the diagnosis of PCOS. A follicle number decision threshold ${\geq}10$ had a sensitivity of 53.2% and a specificity of 90.4%. A follicle number and a ovarian volume did not have a high diagnostic power for screening for PCOS. Conclusion: Our results suggest that transabdominal ultrasound assessment is not effective for the detection of PCOS in young women of reproductive age.

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Oribicularis Oris Muscle Defects in Philtral Deformities in the Repaired Cleft Lip (구순열 수술 후 인중의 변형과 구륜근 결손)

  • Kim, Suk-Wha;Jeong, Yeon-Woo;Cheon, Jung-Eun;Park, Chan-Young;Oh, Myung-June;Kim, Jung-Hong;Choi, Tae-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.427-432
    • /
    • 2010
  • Purpose: The purpose of this study is to estimate muscle defect by ultrasonography in the patients with secondary deformities of the lip. We investigated the association between the muscle defect in the repaired cleft lip and the philtral appearance not only at resting state but also maximal puckering. Methods: From December 2006 to November 2007, 52 children were evaluated after primary or secondary cheiloplasty. Digital photographs were taken both from the front and both three quarter views in repose and at maximal pucker. Video clips were also taken in repose and at maximal pucker. A panel of four, scored the philtral ridge and dimple seen on these photographs and videos by using two visual analog scales. Eminence of the philtral ridge was scored by a 5 point grading scale, from "conspicuous groove" to "normal philtral ridge" and the philtral dimple was scored by 3 point grading scale, from "no dimple" to "prominent dimple". Ultrasound images of the upper lip were made using a linear array transducer at the resting position of the lip and evaluated by a single radiologist. Results: The philtral ridge eminence scored $2.79{\pm}0.54$ and $1.40{\pm}0.53$ at resting and maximal pucker, correlating with "flat" and "conspicous groove". The philtral dimpling scored $1.44{\pm}0.53$ and $2.27{\pm}0.66$ at resting and maximal pucker, correlating with "no dimple" and "slight dimple". Ultrasound imaging showed the average muscle dehiscence to be $3.78{\pm}2.14$ mm at resting position. Correlation between the muscle defect in ultrasound imaging and philtral ridge eminence at rest was statistically significant (p<0.050), but was not significant (p=0.756) at maximal pucker using Spearman's rank correlation. Correlation between the muscle defect in ultrasound imaging and philtral dimpling was not statistically significant both at rest (p=0.920) and at maximal pucker (p=0.815) using Spearman's rank correlation. Conclusion: Quantitative assessment of the muscle defect using ultrasonography correlates with the static philtral appearance, but does not correlate with the dynamic appearance. Also, the size of the muscle defect does not show any correlation with the philtral dimpling. Our findings reveal that ultrasound imaging partially reflect static appearance of philtrum but cannot reflect dynamic appearance and suggest the need for further research to evaluate dynamic appearance.

Design and Construction of Hexgonal Ring-type Transducers for Ultrasonic Hyperthermia (초음파 hyperthermia용 육각환 변환기의 설계및 제작에 관한 연구)

  • Cho, Young-Hwan;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.5-12
    • /
    • 1989
  • In the clinical application of ultrasonic hyperthermia, selective heating of tumor is essential and thus precise control of ultrasonic intensity in both tumor and normal tissue is needed. In this paper, a hexagonal array transducer for ultrasonic hyperthermia is designed and manufactured of which focal point and focal region can be ocntrolled by the digital phase control circuit proposed by authors. Profiles of the focussed ultrasound beam in water and those of temperature in phantom were determined. The experimental and computed results are in good agreement.

  • PDF

Energy Transmission of Elastic Waves in Ultrasonic Transducers (초음파 트랜스듀서의 탄성파 에너지 투과율)

  • Piao, Chunguang;Kim, Dae Jong;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.2
    • /
    • pp.124-132
    • /
    • 2015
  • The paper deals with the energy transmission of the elastic waves obliquely transmitting and refracting through a plate and a pipe. By calculating the transmitting ratio depending on the incidence angle, the angle corresponding to the maximum transmission was determined theoretically and considered in the design of ultrasonic transducers for flow velocimetry. Experiments were carried out by using prototypes of the transducers. Experimentally-obtained transmission ratios were compared with and confirmed the theoretically-calculated results.

Frequency Domain Equivalent Circuit Identification of Ultrasound Transducer (주파수 영역 측정에 의한 초음파 변환기 등가회로 추정)

  • 전병두;임준석;송준일;성굉모
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.325-328
    • /
    • 2000
  • 초음파 변환기의 정합을 위해서는 초음파 변환기의 등가회로 구성이 중요하다. 전통적인 등가회로의 경우 비교적 안정적인 등가회로를 예측하게 해 주지만 초음파변환기 구성에서 일어나는 초음파 변환기 외의 구성품 즉 Backing Material, Acoustic Window Material, Radiation Impedance 등에 의한 부가적인 효과를 모델링하는 데는 한계가 있다. 따라서 좀 더 일반적인 방법으로 초음파 변환기를 모델링하는 방법이 필요하다. 그런 방법의 하나로 주파수 영역 측정에 의한 초음파변환기 등가회로 추정법을 제안한다. 이 방법은 초음파 변환기 제작 시 많이 쓰는 임피던스 분석의 결과를 그대로 사용할 수 있고 또 그것이 없어도 일반 함수발생기와 오실로스코프만으로 측정할 수 있어서 랜덤함수를 발생시키고 이에 대한 출력을 저장해야 데이터를 얻을 수 있는 시간영역 추정법에 대해서 장점을 갖는다.

  • PDF

A recursive scheme for improvement of the lateral resolution in B-scan ultrasonography (회귀방법에 의한 초음파 진단기의 측면해상도 개선에 관한 연구)

  • 김선일;민병구;고명삼
    • 전기의세계
    • /
    • v.31 no.3
    • /
    • pp.204-208
    • /
    • 1982
  • The objective of this paper is to present a digital method for improving the lateral resolution of the B-scan images in the medical applications of ultrasound. The method is based upon a mathematical model of the lateral blurring caused by the finite beam width of the transducers. This model provides a simple method of applying a recursive scheme for image restoration with fast computation time. The point spread function (P.S.F.) can be measured by the reflective signals after scanning the small pins located along the depth of interest. From the measured P.S.F., one can compute the coefficient matrices of the inverse discrete-time dynamic state variable equation of the blurring process. Then, a recursive scheme for deblurring is applied to the recorded B-scan to improve the lateral resolution. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

The Effect of PNF Pattern for Upper Extrimity on the Multifiudus (PNF 상지 운동이 다열근에 미치는 영향)

  • Goo, Bong-Oh
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.3
    • /
    • pp.303-308
    • /
    • 2012
  • Purpose : The purpose of this study is to define the change of lumbar asymmetry multifidus muscles when upper extremity PNF pattern. Methods : For this research, twenty-nine asymptomatic participants were voluntary attended. Under the identical conditions, Multifidus muscles were measured standing position and on L4,L5 vertebral level by MyLabOne (ESAOTE, Netherland with a 3.5MHz covex array transducer). The upper extrimity PNF pattern used to activate the multifidus ipsilateral and cotralateral. Results : Results of analysis showed that at the L4, L5 vertebral level, healthy asymtomativ subjects had asymmetry multifidus muscles size. The depth of the multifidus muscles were significantly increased at contralateral upper extrimity PNF pattern, but no significant differences were comparison ipsilateral with contralateral. Conclusion : The multifidus muscle in asymptomatic subjects clinical significance asymmetry. Contralateral upper extrimity PNF pattern seems to be the most suitable exercise for strenthen the smaller size of the multifidus. This study will be used as a prevention method of LBP.

Inverse Analysis of Ultrasonic Signals of Ceramics Based on Ultrasonic Self-Compensating Technique

  • Lee Joon-Hyun;Cheng Ansheng
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.185-190
    • /
    • 2006
  • An ultrasonic self-calibrating technique for the characterization of a ceramic which was fabricated by change pressing time during the HIP process has been applied by using the ratio of the reflection and transmission coefficients of normal incidence longitudinal waves. The ratio is self-compensated, in that it is independent of the characteristics for transmission and reception of ultrasound by the transducer and the condition of the couplant. The insensitive direction in parameter space is defined as the direction in which the variation of the ratio to changes of two parameters vanishes. For inverse problem the distribution of minima in an error surface is investigated.