• 제목/요약/키워드: Ultrasound transducer

검색결과 195건 처리시간 0.035초

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

레이저를 이용한 탄소섬유강화 복합재료의 비파괴평가 기법에 관한 연구 (A Study on Nondestructive Technique Using Laser Technique for Evaluation of Carbon fiber Reinforced Plastic)

  • 최상우;이준현;변준형;서경철
    • 비파괴검사학회지
    • /
    • 제25권2호
    • /
    • pp.103-109
    • /
    • 2005
  • 섬유강화복합재료의 품질향상을 위하여 제조공정중에 발생하게 되는 층간 분리 및 기공 등의 결함이 온라인상에서 검출되어야 한다. 일반적으로 섬유강화복합재료의 비파괴 평가에 있어서 초음파 평가기법이 널리 이용되고 있으나 기존의 초음파 평가 기법은 초음파 전파를 위하여 접촉이 이루어져야 하는 단점이 있다. 따라서 기존의 초음파 평가기법은 비접촉의 기법이 아니므로 제조공정중에 적용할 수 없다. 비접촉식의 초음파 평가 기법을 구현하기 위하여 광학적 기법의 레이저 기법이 적용되었으며 본 연구에서는 레이저 유도 초음파 발생 기법과 레이저 간섭계를 이용한 수신기법이 섬유강화 복합재료 판재에서 적용되었다. 레이저 유도 초음파는 펄스레이저에 의한 복합재료 표면의 순간적인 가열과 이에 의한 열변형으로 발생되어 전파되며 본 연구에 가속도계, AE센서 등 주파수 범위가 다른 수신센서를 이용하여 전파방향 변화에 따른 유도 초음파를 수신하였으며 수신된 유도초음파의 전파방향에 따른 전파속도를 비교하였다. 또한 비접촉 수신기법으로 레이저 간섭계를 이용하여 탄소섬유강화 복합재료에서의 초음파를 수신하고 그 주파수 특성을 분석하였다.

비접촉식 초음파탐상방법 자동화 기술 (Automatic Noncontact Ultrasonic Inspection Technique)

  • 김영길;안봉영;이승석
    • 비파괴검사학회지
    • /
    • 제13권4호
    • /
    • pp.25-31
    • /
    • 1994
  • 비접촉으로 초음파를 송 수신하며 비파괴검사를 수행하는 EMAT(Electromagnetic Acoustic Transducer)를 이용한 초음파탐상장치를 구성하였고, 이를 3축 구동장치 및 데이타 수집, 처리장치와 연결하여 자동화를 시도하였다. 자동화에 적합하도록 송 수신이 한 몸체로 되어 있으며 인가하는 구동신호의 주파수를 변화시킴으로써 main beam의 방향을 조절할 수 있는 EMAT를 설계 제작하였으며, 제작된 EMAT의 특성을 측정하였다. EMAT를 이용한 초음파탐상장치, 3축 구동장치, 데이타 수집장치들에 대한 제어 및 데이타 처리를 위한 프로그램을 개발하였다. Host로 IBM-PC/AT 급을 사용하였으며, 컴퓨터 화면상에서 실재 장비를 가상적으로 구현하는 기법을 사용하였다. 제작된 전 탐상장치의 성능 분석과 결함 검출 능력을 평가하기 위하여, 인위적으로 결함을 가공한 시험편과 실재 결함이 내재되어있는 용접부에 대한 결함 검출을 시도하였으며, 만족할 만한 측정 결과를 화상으로 얻었다.

  • PDF

독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구 (A Study on Blood Flow Measurement Method using Independent Component Analysis)

  • 조석빈;임동석;백광렬
    • 전자공학회논문지SC
    • /
    • 제44권2호
    • /
    • pp.10-17
    • /
    • 2007
  • 의료용 초음파 시스템으로 혈류 속도를 측정할 때, 순수한 혈류 신호의 검출이 필요하다. 초음파 트랜스듀서를 통해 들어오는 반사 신호는 체세포 조직(tissue), 혈관 벽(blood wall), 적혈구(red blood cell), 잡음(noise) 등이 혼합된 신호이다. 혼합된 신호에서 체세포 조직과 혈관 벽 신호를 클러터(clutter)라고 한다. 본 논문에서는 ICA(independent component analysis)를 적용하여 클러터 신호와 잡음을 효과적으로 제거하는 방법을 제시하였다. Field II 초음파 시뮬레이션 프로그램을 이용하여 초음파 반사 신호를 생성하고, ICA를 사용하여 각 독립 신호들을 분리, 클러터 신호를 제거하여 혈류 신호를 추출했다. 추출전 혈류신호를 2D 자기상관(autocorrelation) 방법으로 혈류 속도를 측정했다. 그리고 PCA(principal component analysis)방법을 적용한 고유 필터(autocorrelation) 방법으로 클러터를 제거한 결과와 비교하였다. 그 결과 잡음 환경에서의 혈류 속도 측정에 ICA 방법이 우수한 적용 결과를 보였다.

후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정 (Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation)

  • 송성진;권성덕;정용무;김영환
    • 한국음향학회지
    • /
    • 제22권1호
    • /
    • pp.61-68
    • /
    • 2003
  • 유도초음파는 얇은 판재와 다층재료를 평가하는데 널리 사용되는데, 이를 정량적으로 이용하기 위해서는 위상 및 군속도의 분산 곡선은 필수적이다. 본 연구에서는 누수 램파의 후방복사 신호를 측정하기 위한 측정장치를 개발하였다. 시험편을 회전시켜서 입사각을 변화시켰으며, 2차원 평면에서 움직이면서 입사 위치를 바꾸었다. 광대역 초음파 탐촉자를 사용하여 탄성판에서 발생하는 누수 램파 후방복사 신호를 측정하였다. 입사각으로부터 위상속도가 결정되며, 이에 해당하는 램파의 특정모드가 판재 내에 강하게 발생되고, 이 램파는 시험편의 앞뒤로 진행하면서 물속으로 에너지를 방출한다. 동일한 탐촉자를 사용하여 누수 램파의 후방복사 신호를 검출하고, 이 신호의 주파수 성분은 분산곡선에 대한 정보를 지닌다. 입사각도와 수신된 파형의 주파수 분석을 통하여 램파의 위상속도 분산곡선을 구하였다. 또한 특정한 입사각에서 입사점을 변화시키면서 초음파 신호의 시간대역 이동으로부터 군속도를 측정하였다.

정상견에서 전방 췌장십이장 동맥의 초음파학적 혈관 저항지수 (Ultrasonographic Resistive Index of the Cranial Pancreaticoduodenal Artery in Normal Conscious Dogs)

  • Eom, Ki-Dong;Lee, Hae-oon;Seong, Yun-sang;Lee, Jeong-min;Lee, Jong-won;Oh, Tae-ho
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.274-277
    • /
    • 2003
  • 임상적으로 건강한 비글견 17두와 췌장염으로 진단된 5두(요크셔테리어 3두, 토이푸들 2두)의 견에서, 화학보정 없이 전방 십이지장동맥(cranial pancreaticodudenal artery: cPDA) 혈관저항지수(resitive index: RI)를 측정하고 이를 비교 평가하였다. RI 측정을 위해 이중 펄스 색도플러 초음파와 11-MHz 선형 위상차 배열 탐촉자를 이용하였다. 췌장염견(0.75$\pm$0.04)견의 평균 RI는 정상견(0.63$\pm$0.04)과 비교하여 유의성(t = 5.79, p = 0.001)있게 증가된 소견을 보였다. 췌장염에 이환 또는 의증 환축에서는 cPDA의 RI 평가 또한 보조적 진단 가치가 있음을 확인하였다.

Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials

  • Alcalde, Murilo Priori;Vivan, Rodrigo Ricci;Marciano, Marina Angelica;Duque, Jussaro Alves;Fernandes, Samuel Lucas;Rosseto, Mariana Bailo;Duarte, Marco Antonio Hungaro
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.23.1-23.9
    • /
    • 2018
  • Objectives: This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Materials and Methods: Sixty maxillary canines were divided into 6 groups (n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Results: Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA (p < 0.05). US improved the push-out bond strength for all the cements (p < 0.05). Conclusions: The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.

기포군 영상분석을 통한 초음파 캐비테이션 현상의 변화 관찰 (Ultrasonic Cavitation Effect Observation Using Bubble Cloud Image Analysis)

  • 노시철;김주영;김진수;강정훈;최흥호
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.124-130
    • /
    • 2011
  • In this study, in order to evaluate the yield of bubble by ultrasonic cavitation in HIFU sonication, the bubble image analysis was performed. The changing phenomenon of cavitation effect according to the sonication condition was discussed by analyzing the bubble image. Especially the appearance of bubble cloud, the size of micro-bubble, and the yield of bubble were considered. The 500 KHz and 1.1 MHz concave type ultrasonic transducers were used for HIFU sonication. Computer controlled digital camera was used to obtain the bubble image, and the binary image processing(binarization coefficient : 0.15) was performed to analyze them. In results of 500 KHz and 1.1 MHz transducer, the area of bubble cloud was increased in proportion to the rise in sonication intensity($R^2$ : 0.7031 and 0.811). The mean size of single microbubble was measured as 98.18 um in 500 KHz sonication, and 63.38 um in 1.1 MHz sonication. In addition, the amount of produced bubble was increased in proportion to sonication intensity. Through the result of this study and further study for variable image processing method, the quantitative evaluation of ultrasonic cavitation effects in HIFU operation could be possible with the linearity associated with the sonication conditions.

고관절 내전근 수축을 이용한 교각운동이 복부근육의 두께에 미치는 영향 (The Effects of Bridge Exercise with Contraction of Hip Adductor Muscles on Thickness of Abdominal Muscles)

  • 이건철;배원식;김지혁
    • 대한물리의학회지
    • /
    • 제9권2호
    • /
    • pp.233-242
    • /
    • 2014
  • PURPOSE: The purpose of this study was to determine the correlation between the hip adductor muscles and abdominal muscles during bridge exercise. METHOD: Participants who met the criteria for this study(n=36) were divided into the three groups. The first experimental group performed normal bridge exercises and the second group performed bridge exercises with the contraction of the hip adductor muscles and the control group didn't perform any exercise. Transversus abdominis muscle thickness was measured by ultrasound imaging with a special transducer head device, at pre exercise, after 2 weeks, 4 weeks, and 6 weeks. RESULT: Data were analyzed using repeated ANOVA with the level of significance set at ${\alpha}=.05$. Transversus abdominis muscle thickness was influenced by contraction of the hip adductor muscles during bridge exercise in people without lower back pain. Compared with normal bridge exercise, transversus abdominis muscle thickness significantly increased in thickness during bridge exercise with contraction of the hip adductor muscles(p<.05). CONCLUSION: The results from this study showed that contraction of the hip adductor muscles during bridge exercise increased change in the transversus abdominis muscle thickness. These results can be a good source to prevent low back pain due to hip adductor weakness. Therefore, inducing activation of hip adductor with abdominal stabilizing exercise is more effective in patients with low back pain.

주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석 (Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering)

  • 강동열
    • 한국광학회지
    • /
    • 제30권2호
    • /
    • pp.48-58
    • /
    • 2019
  • 구면 초점 초음파 측정기에 의해 구형의 광 흡수체로부터 측정된 시간(즉, 펄스 형태 광원) 및 주파수 영역(즉, 처프 형태 광원) 광음향 신호의 신호 대 잡음비(signal-to-noise ratio)를 이론 및 시뮬레이션으로 분석하였다. 이전 문헌과 마찬가지로 시간 영역 광음향 측정에 의한 신호 대 잡음비 값이 주파수 영역 광음향 측정의 경우보다 더 높았는데 이 근본적인 이유를 최대허용노광량(maximum permissible exposure)에 따른 광원의 세기와 주파수 필터링을 통한 두 측정 모드의 광음향 스펙트럼들에 대한 분석을 통해 이해하였다. 또한, 분석의 결과로서 주파수 영역 광음향의 처프 형태 광원에 대한 정합 필터링에 더해 DC 스펙트럼 부분을 제거하니 신호 대 잡음비가 5 dB 정도 상승하는 것을 발견하였다. 특히, 주파수 필터 함수의 주파수 상한 값의 변화에 따라 신호대 잡음비 값이 급격하게 변동하였는데 신호 대 잡음비가 최대가 되는 주파수 상한 값이 두 광음향 측정 모드에서 서로 다르게 나타남을 관찰하였다.