• 제목/요약/키워드: Ultrasound therapy

검색결과 493건 처리시간 0.024초

흰쥐의 급성기 창상치유에 맥동초음파와 냉 적용이 미치는 효과 (The Effects of Pulsed Ultrasound Treatment and Cold Therapy in the Process of Acute Wound Healing)

  • 김태윤;조남정;정화수;김문수
    • 대한임상전기생리학회지
    • /
    • 제5권2호
    • /
    • pp.23-33
    • /
    • 2007
  • Summary of background data: At the wound from life of the human being very regarding at and a healing process the wound in the portion which is important meantime the many research is accomplished and healing process at the wound the research is small very from the physical therapy territory. Purpose: This study was performed to examine the effects of cold therapy and pulsed ultrasound treatment in the process of acute wound healing. To this end, we measured changes in the length of the wounds, and observed tissues through an optical microscope in order to evaluate the healing process of the acute wounds. Methods: We divided twenty Sprague-Dawley rats into four experimental groups of five rats each and treated them for three days after wound creation. Then we extracted tissues from the wounds on day 6th after wound creation and then took them out for hematoxylin-eosin(HE) staining. We measured changes in the length of the wounds every other day. Result: We were able to detect significant statistical differences in the cold therapy and pulsed ultrasound-treated wounds compared with control wounds. We observed tissues through an optical microscope and found the tissues in cold therapy and pulsed ultrasound-treated wounds healed well. Conclusions: Overall results indicated that the use of cold therapy and pulsed ultrasound treatment were effective in the process of acute wound healing.

  • PDF

자외선 조사로 유발된 피부 염증성 반응에 맥동성 초음파가 미치는 영향 (The Effect of Pulsed Ultrasound on Skin Inflammatory Reaction Induced by Ultraviolet Irradiation)

  • 이정우;박수지;윤세원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권4호
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: This study aims to examine the effects of pulsed ultrasound on skin inflammatory reaction induced by ultraviolet irradiation. Methods: Twenty subjects were selected for this study. Inflammatory reaction was induced by ultraviolet irradiation in two areas of the lumbar region of the subjects. Pulsed ultrasound (3 MHz) was applied to one of the two areas of inflammatory reaction at a pulse ratio of 1:4, intensity of $0.5W/cm^2$, once a day for 5 min, and pulsed ultrasound was not applied to the other area. Wound color (chromatic red), luminance (gray) and wound contraction (area) were measured using digital imaging processing method. Results: There was a significant difference in wound color (chromatic red) in the interaction between time and area. There was a significant difference in luminance in the interaction between time and area. There was a significant difference in wound contraction between the two areas. Conclusion: These results indicate that pulsed ultrasound increased the wound contraction rate and reduced the inflammatory reaction activity such as erythema induced by ultraviolet irradiation.

Effect of Using Electrical Stimulation and Ultrasound with Aerobic Exercise on Local Lipolysis

  • Choi, Sug-Ju;Jeong, Jin-Gu;Seo, Sam-Ki
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.13-19
    • /
    • 2010
  • Purpose: This study was designed to measure the effects of weight, abdominal girth, body fat, abdominal fat and cholesterol levels in combination with electrical stimulation, ultrasound and aerobic exercise on obesity and local lipolysis. Methods: Subjects were 30 obese adults who volunteered to take part in the experiment and had no physical diseases. They were randomly divided into three groups: (1) an aerobic exercise group (n=10), (2) an electrical stimulation group with aerobic exercise (n=10), and (3) an ultrasound stimulation group with aerobic exercise (n=10). Each experimental group went through 8 weeks of training. Results: All measured items including weight, girth of the abdomen, body fat, and cholesterol levels showed significant differences among groups. All three groups showed decreases for all items. The electrical stimulation + aerobic exercise group (group II) showed greater effects than the aerobic exercise group (group I) and the ultrasound stimulation group with aerobic exercise (group III). Conclusion: Electrical stimulation + aerobic exercise and ultrasound stimulation + aerobic exercise cause decreases in weight, girth of the abdomen, body fat and cholesterol level compared to aerobic exercise alone. These methods can be considered to be effective adjuvants to aerobic exercise in obese adults.

당뇨유발 모델에서 맥동성초음파와 키토산의 창상치유효과 (The Effect of Wound Healing of Pulsed Ultrasound and Chitosan in Diabetic Induced Model)

  • 김계엽;민순규;정미선
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.50-64
    • /
    • 2004
  • The studies have been designed to evaluate the effect of wound healing of pulsed ultrasound and chitosan application in diabetic incisive wound of rats. Mild diabetes mellitus was induced in rat used 30 mg/kg streptozotocin. Full thickness skin incision was made on the backs of Sprague-Dawley rats. We used 72 Sprague-Dawley rats which were divided into 4 groups; the subjects were divided into group of 6 rats each 3, 6, and 15 days. The results were summarized as follows; The rate of wound length of pulsed ultrasound with chitosan application groups more decreased than only pulsed ultrasound treatment group. The density of inflammatory cells in the experimental groups was more significantly decreased than diabetic control group(p<0.05). Historically, in the ultrasound with chitosan application groups, reepithelized epithelium was thicker and the collagen fiber were organized in a liner manner and connective tissue was matured faster those of the diabetic control group(p<0.05). From the conclusions above, in this study application of pulsed ultrasound and chitosan can be an effective way of promotion of wound healing in diabetic model.

  • PDF

Lidocaine 음파영동에 의한 표면마취 및 전달마취 효과 (The Effect of Topical and Conduction Anesthesia by Phonophoresis with Lidocaine)

  • 정대인;윤세원;최석주;이정우;정진규;김태열
    • 대한임상전기생리학회지
    • /
    • 제4권1호
    • /
    • pp.63-83
    • /
    • 2006
  • This study conducted the following experiment to examine anesthetic effects of 500 kHz ultrasound with lidocaine. Clinical experiment was conducted to compare local anesthetic effects by ultrasound frequencies and drugs with 40 normal adults and it divided subjects into experimental group (I) applying only ultrasound, ointment group (II) applying only lidocaine, phonophoresis group of 1 MHz (III), phonophoresis group of 500 kHz lidocaine (IV) for pain threshold and nerve conduct experiments. Mechanical threshold was measured with von Frey monofilament, thermal pain threshold with halogen lamp and digital thermometer, action potential in median nerve with diagnostic electromyography before and after treatment, and at 30 min., 60 min., 90 min., and 120 min. after treatment. Results of this study can be summarized as follows. Topical anesthesia experiment showed that pain threshold of phonophoresis groups was significantly increased, but there were little differences in ultrasound frequency and drugs among phonophoresis groups. Conduction anesthesia experiment showed that phonophoresis group of 500 kHz using lidocaine had significant difference in pain threshold and sensory nerve conduction compared to ointment group and ultrasound group, but there was no great difference from other phonophresis groups and light nerve block effect was found. It was considered that application of 500 kHz ultrasound using lidocaine will be more effective in deep anesthesia or nerve block than 1 MHz ultrasound. However, researches considering various frequencies, intensities and application hours in low frequency areas including kHz ultrasound are needed to increase deep permeation of drugs.

  • PDF

케틀벨 운동과 초음파 치료가 20대 성인의 체질량지수, 체지방률에 미치는 영향 (The Effects of Kettlebell Exercise and Ultrasound Treatment on Body Mass Index and Percent Body Fat in 20's Adults)

  • 김현진;김명훈
    • 대한물리치료과학회지
    • /
    • 제25권2호
    • /
    • pp.1-6
    • /
    • 2018
  • Background: This study was to examine the influence of BMI and PBF of adults in 20's through the Kettlebell exercise and ultrasound for 4 weeks. Methods: 24 adults men and women, whose BMI is over 23, was divided into 3 groups, group I (control group), group II (Kettlebell exercise group), group III (ultrasound treatment and Kettlebell exercise group). The ultrasound treatment was done before exercise for 15 minutes 3 times a week for 4 weeks, and exercise worked out with Kettlebell exercise during 15 minutes and were stretched for 10 minutes before and after exercise. Results: For 4 weeks of Kettlebell exercise and ultrasound, there was a statistically meaningful difference between group I and group III (p<.05). For 4 weeks, there was no statistically meaningful difference of BMI and PBF between group II and group. I Conclusion: A complex application of Kettlebell exercise and ultrasound treatment was thought to effective decreasing for BMI and PBF.

체외강력집속초음파치료 (Extracorporeal High Intensity Focused Ultrasound Therapy)

  • 한상석
    • 대한골관절종양학회지
    • /
    • 제11권1호
    • /
    • pp.17-24
    • /
    • 2005
  • 의학의 발달과 더불어 종양에 대한 국소치료는 광범위근치술(extended radical surgery) 로부터 기능보존술(function preserving surgery)로 발달하고 이것은 다시 최소침습술(minimal-invasive surgery)로 발전하여 왔다. 그러나 최근 들어서는 기술의 혁신적인 진보로 비침습적수술법(non-invasive surgery)이 개발되어 감마나이프(gamma knife), 사이버나이프(cyber knife), 및 하이푸나이프(HIFU knife) 등이 출현하게 되었다. 본 논문에서는 이들 중 하이푸나이프를 이용한 체외강력집속초음파치료(extracorporeal high intensity focused ultrasound therapy)에 대하여 발달사, 치료기 구조 및 치료과정, 조직학적 변화와 기전, 임상적용, 장단점 및 전망 등을 살펴보고자 한다.

  • PDF

교통사고 후 발생한 후두통의 근골격계 초음파를 이용한 침도치료 임상증례 (The Case Report of Posterior Headache Caused by Traffic Accident Treated with Musculoskeletal Ultrasound-guided Acupotomy Therapy)

  • 박만용;김성하;이상미;이종덕;임진영;권소연;정일민;김성철
    • Journal of Acupuncture Research
    • /
    • 제28권2호
    • /
    • pp.165-172
    • /
    • 2011
  • Objectives : The objective of this case report was to observe the effect of musculoskeletal ultrasound-guided acupotomy therapy on posterior headache caused by traffic accident. Methods : Musculoskeletal ultrasound-guided acupotomy therapy was performed to two patients whose brain MRI or CT results were normal, but posterior headache did not improve with general eastern medical treatment. Results : One patient's VAS(visual analogue scale) of posterior headache was decreased for the first time after ultrasound-guided acupotomy therapy, and steadily reduced. The other patient's VAS was also decreased for the first time after musculoskeletal ultrasound-guided acupotomy therapy. Two patient's Korean HIT-6(Korean headache impact test-6) scores were decreased after one month. Conclusions : If general eastern medical treatment had little effect on traffic accident induced posterior headache, musculoskeletal ultrasound-guided acupotomy therapy can be applied.

운동 전 적용된 지속초음파와 맥동초음파가 운동 유발성 근육 손상의 통증과 근피로대사산물에 미치는 효과 (The effects of pulsed ultrasound and continued ultrasound intervention before an exercise on PPT, CK and LDH of EIMD)

  • 김하늘;전재근;신성필
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.56-66
    • /
    • 2020
  • Background: The purpose of this study was to investigate the effects of pulsed-ultrasound intervention and continued-ultrasound on the PPT (pressure pain threshold), CK (creatine kinase) and LDH (lactate dehydrogenase) recovery of before EIMD (exercise-induced muscle damage). Design: Randomized Controlled Trial. Methods: Thirty subjects who are student in their 20s at a university participated in this study, these subjects were assigned into three groups, a control group (n=10), experiment group I (n=10), and experiment group II (n=10). The subjects in experimental group were intervened by pulsed-ultrasound and continued-ultrasound, while ones on control group weren't by any intervention after induced EIMD. Results: First, In the comparison of the PPT, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the PPT of experimental group II was significantly larger than those of other groups (p<.01). Second, In the comparison of the CK, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the CK of experimental group II was significantly smaller than those of other groups (p<.001). Third, In the comparison of the LDH, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the LDH of experimental group II was significantly smaller than those of other groups (p<.001). Conclusion: The above results revealed that the continued-ultrasound intervention before an exercise had a positive effect of muscle function after EIMD. Therefore we can consider the continued ultrasound as a considerable intervention method to prevent or reduce an exercise injury.

초음파가 생쥐의 혈소판에 미치는 영향 (The effects of Ultrasound on the Platelet of Rats)

  • 조광호;박상옥;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제13권1호
    • /
    • pp.139-149
    • /
    • 2001
  • We found out that there exists threshold dose for the decreased platelet count when we apply change of the platelet count to the defense of the ultrasound experiment. Those diminution is definite effects from the defense of the ultrasound. The number of the platelet count is decreased when we are exposed to ultrasound simultaneously. This should not be occurred. It is easy to use the number of the platelet count in the measurement of the biological dosage and intensity in high dosage relatively due to definite quantative relationship. The biological index to understand synergic effects. which are present when two harmful environmental factors are operating at the same time is functionally assending and antagonistic. There are scattered many factors as physical, Chemical, or physiochemically elements which are harmful to human body in the environment in consideration of ultrasound and the other factors. This experiment is demonstrating that we can use the change of the platelet as an index representing synergic effects of ultrasound.

  • PDF