• Title/Summary/Keyword: Ultrasound sonography

Search Result 55, Processing Time 0.021 seconds

Prognostic Value and Histologic Correlation of Sonography in Childhood Nephrotic Syndrome (신증후군 환아에서 신장초음파의 예후적 가치 및 조직검사와의 상관관계에 대한 연구)

  • Cheon Hae-Won;Yoo Kee-Hwan;Hong Young-Sook
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.26-33
    • /
    • 1998
  • This retrospective study was designed to evaluate the prognostic value and histologic correlation of sonography in childhood nephrotic syndrome. Sixty-nine patients with proteinuria over 2g per day at the time of presentation who were treated at the Korea University Hospital were included in this review. They were 1 to 15 years old(mean age, 7.8 years) with 49 males and 20 females. In each patient an ultrasound examination was done using SPA 1000(Diasonics, C.A., U.S.A.) on admission. Tissue specimens were obtained from 46 patients. The paraffin-embedded specimens were reviewed with special reference to interstitial edema, interstitial fibrosis, tubular atrophy, global sclerosis or inflammatory cell infiltrates. Biopsy proven renal disease were minimal change disease(n=20), focal segmental glomerulosclerosis(n=7), membranous glomerulonephritis(n=2), membranoproliferative glomerulonephritis(n=1), $Henoch-Sch\"{o}nlein$ purpura nephritis(n=6), IgA nephropathy(n=5), poststreptococcal glomerulonephritis(n=2), systemic lupus erythematosus(n=1) and Alport syndrome(n=2). There was a significant relationship between increased cortical echogenicity and global sclerosis or tubular atrophy(P<0.05). But no significant relationship was found between increased cortical echogenicity and interstitial fibrosis, interstitial edema, or inflammatory cell infiltration. In biopsy-proven primary nephrotic syndrome(n=30), no significant relationship was found between the increased conical echogenicity and the interstitial edema, interstitial fibrosis, global sclerosis, tubular atrophy or inflammatory cell infiltration. But there was a significant relationship between increased cortical echogenicity and resistance to corticosteroid (P<0.05). These results suggest that increased cortical echogenicity may be due to tubular atrophy or global sclerosis in patients with proteinuria and may be an effective indicator of resistance to corticosteroid in primary nephrotic syndrome.(J Korean Soc of Pediatr Nephrol 2:26-33, 1998)

  • PDF

Study on Relationship Between Intima Medial Thickness and the Plaque in Stroke Patients on Carotid Artery Sonography (뇌경색 환자에서 초음파로 측정한 경동맥 내막-중막두께와 죽상경화반의 관련성에 대한 연구)

  • Lee, Mi-Hwa;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • The carotid intima-media thickness (IMT) is an early structural marker of the atherosclerotic process and is the only non-invasive test that is currently recommended by the American Heart Association for evaluation of the risk. However, use of this parameter has a limitation because it assumes uniform thickness throughout the blood vessel, whereas atherosclerosis is a focal phenomenon that is confined to intima. In fact, plaque can be found along the atherosclerotic blood vessels even though its value is unknown. The aim of this study is to analyze the carotid plaque and IMT in the stroke patients. We investigated the patients with ischemic stroke, who were admitted to the department of neurology at the Stroke Special Hospital from January to March 2008. After the carotid IMT and plaque were assessed by B-mode ultrasonography, IMT and carotid plaque to risk variables (age, sex) were analyzed. The distribution of CCA IMT was significantly different in terms of age (p = 0.004). Likewise, the distribution of carotid plaque was also significantly different in terms of age (p = 0.006). Carotid plaque was 69 and 92% in normal and abnormal CCA IMTs respectively. The results showed that the CCA IMT was closely associated with carotid plaque.

  • PDF

Postnatal Management of Antenatally Diagnosed Patent Urachus with Bladder Prolapse

  • Choi, Hyun-Shin;Kim, Hae-Eun;Kim, Eun-Sun;Oh, Soo-Young;Chang, Yun-Sil;Seo, Jeong-Meen;Park, Won-Soon
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.262-264
    • /
    • 2010
  • A case of bladder prolapse through a patent urachus is reported in a female infant born with a large, red, tubular mass inferior to the umbilical cord. A cystic mass communicating with fetal bladder was detected by prenatal ultrasound performed at $20^{+2}$ weeks of gestation. A fetal MRI was also performed to confirm the diagnosis and to exclude associated fetal anomalies. At $40^{+4}$ weeks, the cystic mass was no longer present and a new small solid mass was noted at the fetal abdominal wall. After birth, a protruded mucosal mass inferior to the umbilical cord was noted, and catheterization confirmed communication between the protruded mass and the urinary bladder. On the second day of life, reduction of the bladder and partial resection of the urachus was performed. A voiding cystourethrogram showed good bladder capacity and no vesicoureteral reflux. The patient voided well and was discharged after 10 days. Here, we present a case of urinary bladder prolapse through a patent urachus, diagnosed by fetal sonography and this is the first case reported that was treated by simple excision without complication.

Ultrasonographic Utility for Arthroscopic Examination of Knee (슬관절 관절경 검사 시 초음파 검사의 유용성)

  • Byun, Ki-Yong;Rhee, Kwang-Jin;Kim, Kyung-Cheon;Kim, Dong-Kyu;Kim, Bo-Kun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • Purpose: To evaluate the relationship between the real pathology & abnormal finding found by ultrasonography. Without an MRI test being done beforehand, an arthroscopy is done after an ultrasonography to show abnormal lesions during a knee abnormality. Materials and Methods: The subjects were 42 patients out of 49 cases, excluding those with rheumatoid arthritis, septic arthritis and patients suspected with a ligament tear, which were examined by ultrasonography alone before receiving a knee arthroscopy in our hospital from July 2007 to July 2008. In every case, a physical examination, simple X-ray and knee ultrasonography was done. An arthroscopy was performed when there was ultrasonographic abnormal finding. Before the procedure, a MRI test was not performed and when abnormal findings were found by an arthroscopy, an appropriate surgery was done. Results: During the ultrasonographic examination, there were various sized effusions in the suprapatellar pouch. Also, in addition there were eleven cases of medial meniscus abnormalities, sixteen cases of lateral meniscus abnormalities, and two cases of cystic lesions. Throughout the arthroscopic examination, there were 14 cases of medial meniscus abnormalities, 20 cases of lateral meniscus abnormalities, 15 cases of cartilage damages, 9 cases of medial pathologic plica, 2 cases of intra-articular loose bodies, 5 cases of chondromalacia, 2 cases of cyst, and 2 cases of synovitis. When an effusion abnormality was found by the ultrasonography in a suprapatellar pouch, there was a 100% probability of knee pathology. When a medial meniscus abnormality was found with an ultrasonography, there was a 90.9% probability of a real pathology. When a lateral meniscus abnormality was found there was 81.2% probability of a real pathology. Ultrasonography was 100% accurate when it came to cystic lesions. Conclusion: Knee ultrasonography performed before an arthroscopy seems to be a very useful examination method when suspecting intra-articular lesions.

  • PDF

A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography (초음파로 신장의 크기 측정 시 미치는 영향에 관한 연구)

  • Yoon, Seok-Hwan;Kim, Yun-Min;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94cm, and the average length in the left kidney was 11.13cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the kidney.

  • PDF