• 제목/요약/키워드: Ultrasound scan

검색결과 133건 처리시간 0.029초

초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법 (Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval)

  • 임종범;김영기;김성우;성규완;정일;이청
    • The Korean Journal of Pain
    • /
    • 제21권1호
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가 (Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom)

  • 이현경;허영철
    • 한국방사선학회논문지
    • /
    • 제13권6호
    • /
    • pp.895-900
    • /
    • 2019
  • 초음파는 인체에 무해하다고 알려져 산부인과에서 태아의 진단 및 발육상태 확인을 위해 널리 이용되고 있다. 진단 초음파의 장시간 사용은 체온 변화를 야기할 수 있지만 초음파로 인한 임신부의 자궁온도 변화에 대한 연구가 부족한 실정이다. 이에 본 연구에서는 자체 제작한 자궁모형팬텀을 이용하여 초음파 주사시간에 따른 온도 변화를 알아보고자 하였다. 조직등가 물질인 아크릴과 돼지 자궁을 이용하여 인체 자궁과 유사한 자궁모형팬텀을 자체 제작하였으며 초음파 장비와 4MHz convex probe를 사용하였다. 아크릴 수조 내부, 자궁내부, 대기온도 측정을 위해 3개의 탐침형 온도계를 설치하였고 측정대상의 온도를 분단위로 6시간, 총 361회 측정 한 결과 자궁모형팬텀의 온도가 상승되었음을 확인하였다. 본 연구를 통해 초음파로 인한 인체 체온 상승의 가능성을 확인 할 수 있었고 본 연구가 초음파 열 흡수효과 연구의 기초자료로 활용 될 것이라 사료된다.

Predictive Markers for Screening Renal Damage in Children with Urinary Tract infections and Vesicoureteral Reflux

  • Lee, Hyeonju;Choi, Jae Hong;Kang, Dong-Hyeok;Kim, Seunghyo;Kang, Ki-Soo;Han, Kyoung Hee
    • Childhood Kidney Diseases
    • /
    • 제24권1호
    • /
    • pp.27-35
    • /
    • 2020
  • Purpose: Urinary tract infections (UTIs) are the most common and serious bacterial infections in children. Therefore, early diagnosis of vesicoureteral reflux (VUR) for treatment planning and the identification of noninvasive markers that can predict renal injury are important in patients with UTIs. We analyzed the clinical features of pediatric UTIs commonly encountered by general practitioners and reinterpreted the blood tests and imaging findings to identify the important clinical predictive markers of VUR in order to selectively perform VCUG. Methods: This retrospective study was performed among 183 children diagnosed with a UTI or acute pyelonephritis. Results: The most significant predictor of high grade and bilateral VUR identified using area under the curve analyses was hydronephrosis on kidney ultrasound images with renal cortical defects on dimercaptosuccinic acid (DMSA) kidney scan simultaneously, followed by hydronephrosis only on kidney ultrasound. Conclusion: The presence of hydronephrosis on kidney ultrasound images or cortical defects or asymmetric kidneys on the DMSA kidney scans can be predictive markers of VUR, reducing the need for VCUG. Our study can thus help minimize the exposure to radiation among patients through selective VCUG.

병렬 처리 구조의 GPU를 이용한 의료 초음파 영상용 에코 신호 처리기 (An Echo Processor for Medical Ultrasound Imaging Using a GPU with Massively Parallel Processing Architecture)

  • 서신혁;손학렬;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.871-872
    • /
    • 2008
  • The method and results of the software implementation of a echo processor for medical ultrasound imaging using a GPU (NVIDIA G80) is presented. The echo signal processing functions are modified in a SIMD manner suitable for the GPU's massively parallel processing architecture so that the GPU's 128 ALUs are utilized nearly 100%. The preliminary result for a frame of image composed of 128 scan lines, each having 10240 16-bit samples, shows that the echo processor can be inplemented at a high rate of 30 frames per second when implemented in C, which is close to the optimized assembly codes running on the TI's TMS320C6416 DSP.

  • PDF

실시간 혈관내초음파 영상을 위한 후단부 시스템 구현 (Implementation of a backend system for real-time intravascular ultrasound imaging)

  • 박준원;문주영;이준수;장진호
    • 한국음향학회지
    • /
    • 제37권4호
    • /
    • pp.215-222
    • /
    • 2018
  • 본 논문은 실시간 혈관내초음파 영상을 위한 후단부 시스템 개발과 성능 평가 결과에 관한 것이다. 개발한 후단부 시스템은 로직 사용량과 메모리 사용량을 최소화할 수 있는 효율적인 LUTs (Look-up Tables)을 사용하여 외부 메모리 없이 하나의 FPGA (Field Programmable Gate Array)만으로 시스템을 구성함으로써 시스템의 저비용, 소형화, 경량화가 가능하도록 설계하였다. 구현한 후단부 시스템의 정확도는 FPGA의 출력값과 VHDL (VHSIC Hardware Description Language) 코드를 MATLAB 프로그램을 사용하여 동일하게 구현하여 얻은 결과를 비교함으로써 검증하였다. 토끼 동맥을 이용한 ex-vivo 실험을 통하여 개발한 후단부 시스템이 실시간 혈관내초음파 영상에 적합함을 확인하였다.

잡음을 고려한 회귀방법에 의한 초음파 진단기의 화상개선 (A Recursive Restoration Scheme of B-Scan Ultrasonographic Images in Noisy Case)

  • Kim, Sun-I.;Min, Byoung-G.;Ko, Myoung-S.
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권1호
    • /
    • pp.35-42
    • /
    • 1982
  • The objective of this phantom study is to develop a digital method for improving the lateral resolution of B-scan ultrasonographic images irs medical application of ultrasound. By utilizing a discrete state-space modeling approach and Kalman-Buch method for analysis of the transducer's beam profile and the measurement and sampling noise, a stable recursive restoration of the object image was obtained for improved lateral resolution. The point spread function (PSF) was measured for the reflective signals after scanning the small pins located along the depth of interest. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

급성 상기도 폐색을 동반한 이소성 갑상선 기원의 낭종 1예 (A Case of Ectopic Thyroid Cyst Accompanied by Acute Airway Obstruction)

  • 강대운;이윤세;임윤성;이진춘
    • 대한기관식도과학회지
    • /
    • 제17권1호
    • /
    • pp.50-52
    • /
    • 2011
  • Ectopic thyroid gland is a defined as thyroid tissue located in a site other than its usual pre-tracheal location. Ultrasound examination, CT scan, thyroid scan, and thyroid iodine uptake test are all valuable modalities for a differential diagnosis. Although most of cases are asymptomatic, treatment is indicated when there are symptoms related to progressive growth of mass. This article reports a ectopic thyroid cyst in the anterior neck that was similar to deep neck infection accompanied by acute airway obstruction.

  • PDF

873~1,273 K에서 열화된 강화흑연강(Compacted Graphite Iron, CGI)의 초음파특성 (Ultrasonic Characteristics of Degraded Compacted Graphite Iron from 873 to 1,273 K)

  • 이수철;남기우
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.72-78
    • /
    • 2013
  • Compacted graphite iron 340 was carried out the heat treatment from 873 to 1,273 K. Compacted graphite iron 340 was evaluated relationship between the sound velocity, the attenuation coefficient and the tensile strength. The obtained results are as following. The signal strength of C scan images were weak according to increasing of heat treatment temperature and time. The amplitude of A scan and B scan was also low. This can be cause that the graphite was grown into the type of vermicular, and the many of grain boundary with ultrasound scattering were increase. The sound velocity was depend upon the heat treatment temperature and time, the attenuation coefficient had nothing to do with the temperature and time. The higher the heat treatment temperature, the tensile strength and the sound velocity were decreased. However, the tensile strength was proportional to the sound velocity. The higher tensile strength, the faster the sound velocity.

초음파 신호로부터의 음장의 계산 및 평가 (Calculation and Estimation of Acoustical Length from Ultrasound Signal for Diffraction Tomography)

  • Park, Jong-Ho;Park, Jong-Soo
    • 대한전자공학회논문지
    • /
    • 제23권2호
    • /
    • pp.278-284
    • /
    • 1986
  • There are considerabel interests in the use of acoustical lengths for characterization of scattered data required in diffraction tomography. In this paper, we present two new methods, calculation of acoustical lengths by Hibert transform and estimate on of integrated values on the scan lines from calcualted vales. These techniques offer insight into the acquisition of projection data in diffraction tomography. The validity of the proposed methods has bee confirmed by computer simulation.

  • PDF

소아 요로감염에서 배뇨성 방광 요도 조영술의 결정 (The Decision of Voiding Cystourethrography in Children with Urinary Tract Infection)

  • 김동운;최응상;임인석
    • Childhood Kidney Diseases
    • /
    • 제11권2호
    • /
    • pp.203-211
    • /
    • 2007
  • 목 적 : 본 연구에서는 소아에서의 연령과 성별, CRP, 그리고 혈액 내 백혈구 등의 독립적 요소들을 방사선학적 검사와 각각 비교평가하고 배뇨성방광 요도 조영술의 시행이 필요한지에 대하여 평가를 해보고자 한다. 방 법 : 본 연구에는 2002년 1월부터 2005년 1월까지 OO대부속병원 소아청소년과에서 $38^{\circ}C$ 이상의 발열을 주소로 내원하여 요로감염으로 처음 진단받은 98명이 포함되었다. 요로감염의 진단은 소변 배양 검사상 단일 균주가 105 CFU/mL 이상 자랐을 때로 정의하였으며, 신경학적 신장 기능이상이 보이는 환자들은 검사에서 제외하였다. 이들 모두에게 치료시작 전후의 발열기간을 기록하고 CRP, 백혈구 등을 검사하였으며, $^{99m}Tc$-DMSA 신장스캔과 복부-신장초음파, 퇴원 2근주 후 방광요로조영술 등을 시행하였다. 성별에 따른 방사선학적 이상의 빈도와의 관계는 chi-square test로 검정하였고, 연령에 따른 방사선학적 이상의 빈도와의 관계는 logistic regression model로 검정하였다. 방사선학적인 이상을 보인 환자군에서 진단당시의 발열기간, 백혈구, CRP 수치의 차이가 있는지를 알아보기 위하여 t-test를 사용하여 검증하였고 방사선 검사들을 chi-square test로 비교하여 양성간의 상관관계를 분석하였으며 유의 수준은 P<0.05로 하였다. 결 과 : 요로감염이 진단된 98명의 환아 중에서 52명이 남자 환자였고 46명이 여자 환자였다. 총98명의 환자들 중 배뇨성 방광 요도 조영술 검사상 이상소견을 보인 경우가 총18명이었고, 신장-복부초음파 결과에서 이상소견을 보인 경우는 총17명이었으며, $^{99m}Tc$-DMSA 신장 스캔에서 부분적 결손이나 미만성 섭취감소를 보인 경우는 총20명이었다. 각 연령과 성별에서의 방사선검사 결과들과의 상관관계는 통계학적으로 유의 한 차이를 보이지 않았다(Table 1, 2). 치료 전의 발열기간에서 신반흔을 보인 군이 음성인 군보다 발열기간이 길었다(Table 3). CRP, 백혈구는 방사선학적 이상소견이 있는 군에서 통계학적으로 유의하게 높았다(Table 4, 5). $^{99m}Tc$-DMSA 신장 스캔과 신초음파 검사의 양성유무는 배뇨성 방광 요도 조영술 검사의 양성유무와 통계적으로 유의한 상관관계를 보였다(Table 6, 7). 결 론 : 치료 전 발열기간, 입원 당시 백혈구, CRP에 기초한 임상적 평가는 첫 요로감염 질환에 걸린 환아들의 방광 요관 역류 여부를 예측하는데 유용하며, 추가적인 방사선학적 검사가 필요한지 에 대해 지침을 제공할 수 있다. 소아의 첫 요로감염시 초음파나 $^{99m}Tc$-DMSA 신장 스캔상에서 양성소견이 있을 경우 배뇨성 방광 요도 조영술 검사를 시행하는 것이 좋으며, 초음파와 $^{99m}Tc$-DMSA 신장 스캔상에서 양성소견이 없을 경우라도 CRP 또는 백혈구 등의 임상자료들을 평가하여 배뇨성 방광 요도 조영술 검사를 시행유무를 결정하는 것이 잔존하는 방광요관역류를 찾는데 도움이 될 것으로 생각된다.

  • PDF