• 제목/요약/키워드: Ultrasound probe

검색결과 97건 처리시간 0.03초

초기 폐암에서 기관지 초음파 내시경의 임상적 유용성 (Endobronchial Ultrasound in Early Lung Cancer)

  • 박진경;황보빈
    • 대한기관식도과학회지
    • /
    • 제17권1호
    • /
    • pp.9-13
    • /
    • 2011
  • Endobronchial ultrasound (EBUS), which enables visualization of lesions beyond the bronchus, broadens the fields of bronchoscopy. Two types of ultrasound, radial and linear, are used for bronchoscopy. Radial EBUS is performed by inserting an ultrasound mini-probe through the working channel of a flexible bronchoscope. Evaluation of the depth of invasion of early endobronchial lung cancers using radial EBUS is useful in deciding endobronchial treatment. A central tumor limited to within the cartilaginous layer is a good indication for endobronchial photodynamic therapy. EBUS-guide sheath (GS) technique is a sampling method assisted by localization of peripheral lesions using EBUS. The diagnostic yield of EBUS-GS method is higher than that of conventional transbronchial biopsy. High diagnostic values of EBSU-GS method are reported even in small (${\leq}2cm$) peripheral tumors. Linear EBUS is used for endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA). EBUS-TBNA has high diagnostic yields in mediastinal staging of lung cancer even in patients having radiologically early stage lung cancers with normal CT or PET findings in the mediastinum. EBUS is a valuable method in evaluating early endobronchial tumors and peripheral small lung cancers and as well as in mediastinal staging.

  • PDF

초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정 (Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • 한국수정란이식학회지
    • /
    • 제12권2호
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF

초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석 (An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination)

  • 전철민;한재복;곽종길;송종남
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.751-759
    • /
    • 2022
  • 현재 진단 초음파 및 건강검진 목적의 초음파 검사는 널리 이용되고 있고 건강보험 적용으로 더욱 증가 추세를 보이고 있다. 하지만 초음파검사의 위해성은 현재까지 명확히 밝혀진 바가 없어 초음파 검사 시 인체 조직의 온도가 상승하는 열효과를 알아보고자 본 연구에서는 인체 모의 매질 팬텀을 이용해 주파수, 모드별에 따른 표면과 심부 온도 변화를 시간별로 측정하였고 TI, MI 값도 비교하였다. 인체와 유사한 음향 특성 있는 카파 카라기난 분말과 고형화를 위해 염화칼륨을 소량 첨가하여 모의 팬텀 제작하였고 표면 온도계와 탐침용 온도계를 사용하여 표면과 심부 온도 변화를 측정하였다. 그 결과 저주파수를 사용하는 Convex Probe가 고주파를 사용하는 Linear Probe보다 높은 온도 상승을 보여 유의미한 차이를 보였고 표면에서 온도 상승이 가장 높았으며 1 cm의 낮은 깊이는 일시적 온도상승은 나타내지만 유의미한 온도변화는 없었다. 5 cm ~ 15 cm의 심부온도 변화는 없었으며 검사 시간동안 TI, MI값은 변화가 없었다. 이는 15분 실험동안 표면온도만 상승하였고 심부에는 온도변화가 없었기 때문에 인체에 유해할 만큼의 온도 변화를 나타내지 않을 것으로 사료되며 통상적인 진단초음파의 15분의 검사시간은 임상에서의 사용에는 무리가 없을 것으로 생각되지만 특정 부위의 장시간 검사는 온도 상승을 일으킬 수 있으므로 지양해야 될 것으로 사료된다.

결함 화상화를 통한 NAUT 특성평가 연구 (The Research on NAUT Characteristics Evaluation by Defection Image)

  • 나선영;김재열
    • Tribology and Lubricants
    • /
    • 제26권6호
    • /
    • pp.341-345
    • /
    • 2010
  • The NAUT(Non contact Air coupled Ultrasonic Testing) is one of the ultrasonic wave inspection methods. It compensates High power ultrasound Pulser Receiver, pre-amp, air probe of high sensitivity in air to generate loss energy by NAUT methods. Generally, in case of ultrasound inspection, it applies contact methods by using couplant. However it can inspect of UT without couplant by this NAUT. The ultrasound transmission reception is composed in stable condition in NAUT. It can inspect high low material or the specimen of rough part, the narrow spot, too. The spot welding is applying the inosculation of automobile component, car body, all boards. The CFRP is necessity of NDE because of the solidity changes material according to lamella tearing. Therefore it checked on realization whether and commercialization in the spot welding and CFRP inspection that the NAUT would be applied them.

초음파 전립선 영상에서 전립선 경계 분할을 위한 평균 형상 모델 (An Average Shape Model for Segmenting Prostate Boundary of TRUS Prostate Image)

  • 김상복;정주영;서영건
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제3권5호
    • /
    • pp.187-194
    • /
    • 2014
  • 전립선암은 전립선에 나타나는 악성 종양이다. 현재 그 발병률이 높아지고 있다. 전립선암의 구조를 가장 정확하게 확인할 수 있는 검사 방법은 MRI를 이용하는 것이나, 그 비용 때문에 모든 환자에게 적용하기는 어려운 실정이다. 그래서 많은 환자들은 가격이 저렴한 초음파검사를 이용하여 전립선암을 진단하고 있다. 전통적으로 의사들은 영상을 눈으로 확인하여 전립선의 경계를 수동으로 분할하였다. 그러나 수동으로 분할하는 과정은 시간이 많이 소요되며, 의사에 따라서 그 경계가 일정하지 않게 얻어진다. 이 문제를 해결하기 위하여 전립선의 자동 분할에 관한 연구가 되었고, 환자들에게 신뢰를 줄 수 있었다. 본 연구는 초음파 전립선 영상에서 전립선의 경계를 분할하는데 평균 형상 모델을 적용하는 것이다. 먼저, 에지 분포를 이용하여 프로브를 찾고, 프로브와 연결된 두 직선을 찾는다. 이 후에 이 정보를 이용하여 전립선 영상 위에 평균 형상을 위치시킨다.

Genetic Analysis of Ultrasound and Carcass Measurement Traits in a Regional Hanwoo Steer Population

  • Hwang, Jeong Mi;Cheong, Jae Kyoung;Kim, Sam Su;Jung, Bong Hwan;Koh, Myung Jae;Kim, Hyeong Cheol;Choy, Yun Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권4호
    • /
    • pp.457-463
    • /
    • 2014
  • Ultrasound measurements of backfat thickness (UBF), longissimus muscle area (ULMA) and marbling score (UMS) and carcass measurements of carcass weight (CW), backfat thickness (BF), longissimus muscle area (LMA), and marbling score (MS) on 7,044 Hanwoo steers were analyzed to estimate genetic parameters. Data from Hanwoo steers that were raised, finished in Hoengseong-gun, Gangwon-do (province) and shipped to slaughter houses during the period from October 2010 to April 2013 were evaluated. Ultrasound measurements were taken at approximately three months before slaughter by an experienced operator using a B-mode real-time ultrasound device (HS-2000, FHK Co. Ltd., Tokyo, Japan) with a 3.5 MHz linear probe. Ultrasound scanning was on the left side between 13th rib and the first lumbar vertebrae. All slaughtering processes and carcass evaluations were performed in accordance with the guidelines of beef grading system of Korea. To estimate genetic parameters, multiple trait animal models were applied. Fixed effects included in the models were: the effects of farm, contemporary group effects (year-season at the time of ultrasound scanning in the models for UBF, ULMA, and UMS, and year-season at slaughter in the models for CW, BF, LMA, and MS), the effects of ultrasound technicians as class variables and the effects of the age in days at ultrasound scanning or at slaughtering as linear covariates, respectively for ultrasound and carcass measures. Heritability estimates obtained from our analyses were 0.37 for UBF, 0.13 for ULMA, 0.27 for UMS, 0.44 for CW, 0.33 for BF, 0.36 for LMA and 0.54 MS, respectively. Genetic correlations were strongly positive between corresponding traits of ultrasound and carcass measures. Genetic correlation coefficient between UBF and BF estimate was 0.938, between ULMA and LMA was 0.767 and between UMS and MS was 0.925. These results suggest that ultrasound measurement traits are genetically similar to carcass measurement traits.

저주파수 TRL 탐촉자를 이용한 Cast Stainless Steel 배관 용접부 초음파탐상기법 (UT Inspection Technique of Cast Stainless Steel Piping Welds Using Low Frequency TRL UT Probe)

  • 신건철;장희준;전영철;노익준;이동진
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.29-36
    • /
    • 2010
  • Ultrasonic inspection of heavy walled cast austenitic stainless steel(CASS)welds is very difficult due to complex and coarse grained structure of CASS material. The large size of anisotropic grain strongly affects the propagation of ultrasound by severe attenuation, change in velocity, and scattering of ultrasonic energy. therefore, the signal patterns originated from flaws can be difficult to distinguish from scattered signals. To improve detection and sizing capability of ID connected defect for heavy walled CASS piping welds, the low frequency segmented TRL Pulse Echo and Phased Array probe has been developed. The experimental studies have been performed using CASS pipe mock-up block containing artificial reflectors(ID connected EDM notch). The automatic pulse echo and phase array technique is applied the detection and the length sizing of the ID connected artificial reflectors and the results for detection and sizing has been compared respectively. The goal of this study is to assess a newly developed ultrasonic probe to improve the detection ability and the sizing of the crack in coarse-grained CASS components.

  • PDF

방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템 (Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods)

  • 윤용현;조문재;김용태;이명호
    • 한국음향학회지
    • /
    • 제29권6호
    • /
    • pp.355-364
    • /
    • 2010
  • 초음파 진단장치의 음향출력 특성은 전기음향 변환 장치인 배열 탐침자의 성능에 크게 영향을 받으며, 생물학적안전 측면에서 매우 중요하다. 본 논문에서는 초음파 진단장치용 배열 탐침자로부터 방사되는 음향파워를 소자별로 측정할 수 있는 자동화 시스템을 구성하였으며, 곡선형 탐침자의 경우 각 소자의 지향성이 측정에 미치는 영향을 확인하고 이를 보정하는 기법을 개발하였다. 선형, 위상형, 곡선형 배열 탐침자를 대상으로 음향파워 측정결과, 본 논문에서 제시하는 측정기법은 배열 탐침자의 음향파워 특성을 평가하는데 적합함을 확인하였다.

초음파 섹터 B-스캐너의 개발(I)-프론트 엔드 부분- (Development of Ultrasound Sector B-Scanner(I)-Front End Hardware Part-)

  • 권성재;박종철
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권1호
    • /
    • pp.59-66
    • /
    • 1986
  • 개발된 초음파 섹터 B-스캐너 시제품에서 프론트 엔드 하드웨어는 초음파펄스의 송신 및 수신을 담당하는 부분으로서 변환자에 펄스를 인가하는 펄스발생기, 진폭이 미약한 애널로그 신호를 처리하는 수신회로 및 기계식 섹터 탐촉자를 구동하는 조향제어회로의 3부분으로 크게 나눌 수 있다. 본 논문에서는 위 3부분의 기능 및 설계에 관하여 기술한다. 완성된 프론트 엔드 하드웨어의 특징 가운데 중요한 몇가지만 살펴보면, 링다운 시간을 감소시키는 펄스발생기를 사용하여 축방향의 해상도를 증가시켰고 시가변이득 증폭기에 필요한 제어전압을 여러 형태로 만들 수 있으며 탐촉자내에 있는 감지기의 출력파형을 기준으로 본 초음파 진단장치의 모든 시스템에 공급될 레이트 펄스를 만들어 주는 것이라고 말할 수 있다.

  • PDF

영상피드백을 적용한 골반저근 수축이 복부 근 두께에 미치는 영향 (The Effect of Pelvic Floor Muscle Contraction with Image Feedback on Abdominal Muscle Thickness)

  • 김진희;김난수;장준혁
    • 대한물리의학회지
    • /
    • 제7권4호
    • /
    • pp.533-539
    • /
    • 2012
  • PURPOSE: The purpose of this study was to investigate the effect of pelvic floor muscle contraction with image feedback on Abdominal muscle thickness. METHODS: Twenty three adults participated in this study. Abdominal muscle thickness was measured by ultrasound in three condition(rest, pelvic floor muscle contraction, pelvic floor muscle contraction with image feedback). Subjects was contraction pelvic floor muscle by general method. And ultrasound(convex probe, 3.5MHz) was used to image feedback for selective pelvic floor muscle contraction. One-way ANOVA was used to compare abdominal muscle thickness in three condition. RESULTS: There was no significant difference in external oblique(p=.514) and internal oblique muscle(p=.250) thickness by three condition. There was significant difference in transverse abdominis thickness by three condition (Transverse abdominis thickness was highest while Pelvic floor muscle contraction than pelvic floor muscle contraction with image feedback and rest.)(p=.000). CONCLUSION: This study shows that pelvic floor muscle contraction with image feedback increase the thickness of transverse abdominis lesser than general pelvic floor muscle contraction.