• Title/Summary/Keyword: Ultrasound probe

Search Result 97, Processing Time 0.024 seconds

Pregnancy diagnosis in goat by using vaginal cytology and trans-abdominal ultrasonography

  • Ali, Md. Aziz;Islam, Md. Faruk;Rahman, SM Latifur;Zohara, Begum Fatema
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.4
    • /
    • pp.338-346
    • /
    • 2020
  • The present study was conducted in a goat farm for pregnancy diagnosis by using vaginal cytology and B-mode real time ultrasound using 5 MHz probe by transabdominal method. Seventeen pregnant does were used for this study. The objective of the study was to determine the earliest day of pregnancy and describe the chronological characteristics of pregnancy from day 22 to day 40 for vaginal cytology and day 25 to day 60 for ultrasonography of gestation. The differences among the average percentage of cell value in different age of pregnancy were significant (p < 0.05). The average percentage of intermediate cells (81.12%) was also significantly (p < 0.05) higher than superficial (9.41%), keratinized (7.10%) and neutrophil (2.61%) on 22-40th days of pregnancy. In case of real time B-mode ultrasonography, the gestational sac was observed only in three does out of seventeen (17.6 %) at 25-30 days whereas the placentomes and heart beat of the foetus were first detected at 31-35 days in six does (35.3%). The foetal leg buds were first visualized at 36-40 days in four does (23.5%) whereas the foetal vertebral column was first observed at 36-40 days of gestation in only three does (17.6%). In conclusion, vaginal cytology and trans-abdominal ultrasonography can be used for detection of early pregnancy in does.

Endoscopic Bio-Imaging Using Optical Coherence Tomography (마이크로 내시경 및 첨단 광 단층촬영기법을 이용한 생체 이미징)

  • Ahn, Yeh-Chan;Brenner, Matthew;Chen, Zhongping
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 2011
  • Optical coherence tomography(OCT) is an emerging medical diagnostic tool that draws great attention in medical and biological fields. It has a 10-100 times higher spatial resolution than that of the clinical ultrasound but lower imaging depth such as 1-2 mm. In order to image internal organs, OCT needs an endoscopic probe. In this paper, the principle of Fourier-domain optical coherence tomography with high-speed imaging capability was introduced. An OCT endoscope based on MEMS technology was developed. It was attached to the Fourier-domain OCT system to acquire three-dimensional tomographic images of gastrointestinal tract of New Zealand white rabbit. The endoscope had a two-axis scanning mirror that was driven by electrostatic force. The mirror stirred an incident light to sweep two-dimensional plane by scanning. The outer diameter of the endoscope was 6 mm and the mirror diameter was 1.2 mm. A three-dimensional image rendered by 200 two-dimensional tomographs with $200{\times}500$ pixels was displayed within 3.5 seconds. The spatial resolution of the OCT system was 8 ${\mu}m$ in air.

Availability of the Optic Nerve Sheath Diameter Measured by Using Ultrasonography as a Secondary Survey for Patient with Head Injuries in the Emergency Department (응급실에 내원한 두부외상환자의 2차 평가로써 초음파를 이용한 시각신경집 지름 측정은 유용한가?)

  • Lee, Dong Wook;Lee, Jung Won;Park, Sae Hoon;Park, Ihl Sung;Lee, Hyun Jung;Yoo, Byeong Dae;Moon, Hyung Jun
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Bedside ultrasonography is available in most emergency departments, and detecting the intracranial pressure is elevated is critical. Our objective is to evaluate the availability of bedside optic nerve ultrasound (ONUS) as a secondary survey for patients with head injuries in the emergency department (ED). Methods: From September, 2012, to March, 2013, we performed a prospective study of patients presenting to the ED after an accident. Patients with head injuries but without obvious ocular trauma or ocular disease were included. The ONUS was performed using a 3 to 12 MHz linear probe on closed eyelids after a primary survey. We analyzed the correlation between the brain computed tomography (CT) findings that suggested elevated intracranial pressure (ICP) and the Optic nerve sheath diameter (ONSD) measured by using ONUS. Results: A total of 81 patients were enrolled. Forty-seven had CT results consistent with elevated ICP, and their mean ONSD was $5.98{\pm}0.59$ mm; the mean ONSD of patients who showed no signs of elevated ICP on CT was $4.63{\pm}0.21$ mm. The sensitivity and the specificity for the ONSD, compared with elevated ICP, were 98.87% and 100%, respectively, when the cut-off value was set to 4.96 mm. The area under curve (AUC) was 0.997 in the receiver operating characteristic curve (ROC curve). Conclusion: An evaluation using ONUS is a simple noninvasive procedure and is a potentially useful tool as a secondary survey to identify an elevated ICP.

Effect of Chlorhexidine Mouthrinse on Prevention of Microbial Contamination during EBUS-TBNA: A Study Protocol for a Randomized Controlled Trial

  • Kim, Na Young;Park, Jae Hyeon;Park, Jimyung;Kwak, Nakwon;Choi, Sun Mi;Park, Young Sik;Lee, Chang-Hoon;Cho, Jaeyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard diagnostic method for mediastinal and hilar lymphadenopathy. Although rare, fatal infectious complications can occur following EBUS-TBNA. However, to date, there is a lack of effective preventive strategies to reduce these complications. We started a trial to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Methods: This study is a single-center, parallel-group, assessor-blinded randomized controlled trial (RCT). We will enroll 112 adult participants undergoing EBUS-TBNA using a convex probe, and randomly assign them to two groups at a 1:1 ratio. The intervention group will gargle for 1 minute with 100 mL of 0.12% chlorhexidine gluconate before EBUS-TBNA, while the control group will have no mouthrinse before the procedure. Immediately after completion of EBUS-TBNA on all targeted lesions with an aspiration needle, a needle wash sample will be taken by instilling 5 mL of sterile saline into the used needle. The primary outcome is colony forming unit (CFU) counts in aerobic cultures of the needle wash samples. Secondary outcomes are CFU counts in anaerobic cultures, fever within 24 hours after EBUS-TBNA, and infectious complications within 4 weeks after EBUS-TBNA. Conclusion: This trial was designed as the first RCT to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Results from this trial can provide clinical evidence for a simple, safe, and cost-effective strategy to prevent infectious complications following EBUS-TBNA (ClinicalTrials.gov ID: NCT04718922, registered on 22 January 2021).

M-mode Ultrasound Assessment of Diaphragmatic Excursions in Chronic Obstructive Pulmonary Disease : Relation to Pulmonary Function Test and Mouth Pressure (만성폐쇄성 폐질환 환자에서 M-mode 초음파로 측정한 횡격막 운동)

  • Lim, Sung-Chul;Jang, Il-Gweon;Park, Hyeong-Kwan;Hwang, Jun-Hwa;Kang, Yu-Ho;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.736-745
    • /
    • 1998
  • Background: Respiratory muscle interaction is further profoundly affected by a number of pathologic conditions. Hyperinflation may be particularly severe in chronic obstructive pulmonary disease(COPD) patients, in whom the functional residual capacity(FRC) often exceeds predicted total lung capacity(TLC). Hyperinflation reduces the diaphragmatic effectiveness as a pressure generator and reduces diaphragmatic contribution to chest wall motion. Ultrasonography has recently been shown to be a sensitive and reproducible method of assessing diaphragmatic excursion. This study was performed to evaluate how differences of diaphragmatic excursion measured by ultrasonography associate with normal subjects and COPD patients. Methods: We measured diaphragmatic excursions with ultrasonography on 28 healthy subjects(l6 medical students, 12 age-matched control) and 17 COPD patients. Ultrasonographic measurements were performed during tidal breathing and maximal respiratory efforts approximating vital capacity breathing using Aloka KEC-620 with 3.5 MHz transducer. Measurements were taken in the supine posture. The ultrasonographic probe was positioned transversely in the midclavicular line below the right subcostal margin. After detecting the right hemidiaphragm in the B-mode the ultrasound beam was then positioned so that it was approximately parallel to the movement of middle or posterior third of right diaphragm. Recordings in the M-mode at this position were made throughout the test. Measurements of diaphragmatic excursion on M-mode tracing were calculated by the average gap in 3 times-respiration cycle. Pulmonary function test(SensorMedics 2800), maximal inspiratory(PImax) and expiratory mouth pressure(PEmax, Vitalopower KH-101, Chest) were measured in the seated posture. Results: During the tidal breathing, diaphragmatic excursions were recorded $1.5{\pm}0.5cm$, $1.7{\pm}0.5cm$ and $1.5{\pm}0.6cm$ in medical students, age-matched control group and COPD patients, respectively. Diaphragm excursions during maximal respiratory efforts were significantly decreased in COPD patients ($3.7{\pm}1.3cm$) when compared with medical students, age-matched control group($6.7{\pm}1.3cm$, $5.8{\pm}1.2cm$, p< 0.05}. During maximal respiratory efforts in control subjects, diaphragm excursions were correlated with $FEV_1$, FEVl/FVC, PEF, PIF, and height. In COPD patients, diaphragm excursions during maximal respiratory efforts were correlated with PEmax(maximal expiratory pressure), age, and %FVC. In multiple regression analysis, the combination of PEmax and age was an independent marker of diaphragm excursions during maximal respiratory efforts with COPD patients. Conclusion: COPD subjects had smaller diaphragmatic excursions during maximal respiratory efforts than control subjects. During maximal respiratory efforts in COPD patients, diaphragm excursions were well correlated with PEmax. These results suggest that diaphragm excursions during maximal respiratory efforts with COPD patients may be valuable at predicting the pulmonary function.

  • PDF

Practical Applications of DNA Marker-Assisted Selection and OPU-Derived IVF Embryo Transfer for the Production of High Quality Meat in Hanwoo II. Production of IVF Embryos Derived Transvaginal Ovum Pick-up from DNA Marker-Proved Hanwoo (유전자 분석을 통하여 선발된 한우로부터 초음파 유래 체외수정란 이식에 의한 고품질 한우 생산기술의 실용화 II. DNA 검정우로부터 초음파 유래 체외수정란의 생산에 관한 연구)

  • 박희성;이지삼;진동인;박준규;홍승표;이명열;정장용
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.193-201
    • /
    • 2001
  • This study was designed to examine the factors affecting in fertilization and development of embryos in vitro, and to examine whether zone drilling by laser irradiation can improve the hatching rate of IVF embryos from DNA marker-proved Hanwoo. DNA markers related to marbling score were identified using DNA fingerprinting with Ml3 probe and restriction enzyme Hae III. Oocytes were aspirated from immature ovarian follicles using a combined method of rectal ovarian-palpation and transvaginal ultrasound-guidance(6.5MHz) under local anesthesia. The aspirated oocytes were washed twice with fresh D-PBS containing 5% FBS and were rewashed 4 to 5 times with TCM-199 containing 5% FBS. A morphological grade of I to IV was assigned to each oocyte. Data were analyzed using the GLM procedure of SAS. Sperm separation methods did not have any significant effect on cleavage or developmental abilities of IVF embryos. Significantly(P<0.05) higher cleavage rate was observed in embryos from GI(60.0%, 3/5), GII(69.2%, 18/26) and GIII(62.1%, 59/95) compared to embryos from GIV oocytes(36.2%, 25/69). And the developmental rate to blastocyst stage was higher(P<0.05) in embryos from GI(33.3%, 1/3) and GII oocytes(38.9%, 7/18) than those from GIII(16.9%,10/59) and GIV oocytes(4.0%, 1/25). There was no significant difference in development of IVF embryos to blastocyst by media for in vitro culture. Proportion of hatched blastocyst was significantly(P<0.05) higher in embryos received zona drilling by laser than those of non-drilled.

  • PDF

A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography (초음파로 신장의 크기 측정 시 미치는 영향에 관한 연구)

  • Yoon, Seok-Hwan;Kim, Yun-Min;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94cm, and the average length in the left kidney was 11.13cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the kidney.

  • PDF