• Title/Summary/Keyword: Ultrasound image compression

Search Result 14, Processing Time 0.02 seconds

Real-time Ultrasound Contexts Segmentation Based on Ultrasound Image Characteristic (초음파 영상 특성을 이용한 실시간 초음파 영역 추출방법)

  • Choi, Sung Jin;Lee, Min Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.179-188
    • /
    • 2019
  • In ultrasound telemedicine, it is important to reduce the size of the data by compressing the ultrasound image when sending it. Ultrasound images can be divided into image context and other information consisting of patient ID, date, and several letters. Between them, ultrasound context is very important information for diagnosis and should be securely preserved as much as possible. In several previous papers, ultrasound compression methods were proposed to compress ultrasound context and other information into different compression parameters. This ultrasound compression method minimized the loss of ultrasound context while greatly compressing other information. This paper proposed the method of automatic segmentation of ultrasound context to overcome the limitation of the previously described ultrasound compression method. This algorithm was designed to robust for various ultrasound device and to enable real-time operation to maintain the benefits of ultrasound imaging machine. The operation time of extracting ultrasound context through the proposed segmentation method was measured, and it took 311.11 ms. In order to optimize the algorithm, the ultrasound context was segmented with down sampled input image. When the resolution of the input image was reduced by half, the computational time was 126.84 ms. When the resolution was reduced by one-third, it took 45.83 ms to segment the ultrasound context. As a result, we verified through experiments that the proposed method works in real time.

A Study on the Implementation of Multimedia Remote Ultrasound Image Transfer System through ISDN (ISDN(Integrated Services Digital Network)을 통한 멀티미디어 원격 초음파 영상 전달 시스템 구현에 관한 연구)

  • 이영훈;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.33-42
    • /
    • 1996
  • A multimedia remote ultrasound image transfer system for tole-medical services was implemented. The image data of the ultrasound scanner system of the slave is compressed using image compression system. It is transferred to the master PC via ISDN UNI(User-Network Interface) and decompressd by image decompression system. The total system is composed of three parts; first, the image capture card which transfers bidirection- al data between ultrasound scanner system and PC, second, image compression and decompression card, finally, ISDN TA(Terminal Adaptor) card for transferring the image. This system has a easy user interface because it is executed on the basis of MS-WINDOWS. So it is capable of serving medical services at a remote place.

  • PDF

Fast Ultrasound Image Compression Based on Characteristics of Ultrasound Images (초음파 영상특성에 기반한 고속 초음파 영상압축)

  • Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.70-71
    • /
    • 1998
  • In this paper, We proposed fast ultrasound image compression based on characteristics of ultrasound images. In the proposed method, wavelet transform is performed for non-zero coefficients selectively. It codes zero-tree symbols using conditional pdf (probability density function) as orientation of bands. It normalizes wavelet coefficients with threshold of each wavelet band and encodes those using a uniform quantizer. Experimental results show that the proposed method is the proposed method is superior in PSNR to LuraTech's method by about 1.0 dB, to JPEG by about 5.0 dB for $640\times480$ 24bits color ultrasound image.

  • PDF

Medical Image Compression using Adaptive Subband Threshold

  • Vidhya, K
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.499-507
    • /
    • 2016
  • Medical imaging techniques such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) and Ultrasound (US) produce a large amount of digital medical images. Hence, compression of digital images becomes essential and is very much desired in medical applications to solve both storage and transmission problems. But at the same time, an efficient image compression scheme that reduces the size of medical images without sacrificing diagnostic information is required. This paper proposes a novel threshold-based medical image compression algorithm to reduce the size of the medical image without degradation in the diagnostic information. This algorithm discusses a novel type of thresholding to maximize Compression Ratio (CR) without sacrificing diagnostic information. The compression algorithm is designed to get image with high optimum compression efficiency and also with high fidelity, especially for Peak Signal to Noise Ratio (PSNR) greater than or equal to 36 dB. This value of PSNR is chosen because it has been suggested by previous researchers that medical images, if have PSNR from 30 dB to 50 dB, will retain diagnostic information. The compression algorithm utilizes one-level wavelet decomposition with threshold-based coefficient selection.

Enhanced Strain Imaging Using Quality Measure

  • Jeong, Mok-Kun;Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.3E
    • /
    • pp.84-94
    • /
    • 2008
  • Displacement estimation is a crucial step in ultrasonic strain imaging. The displacement between a pre- and postcompression signal in the current data window is estimated by first shifting the postcompression signal by the displacement obtained in the previous data window to reduce their decorrelation and then determining the remaining part of the displacement through autocorrelation and conversion of phase difference into time delay. However, since strain image quality tends to vary with the amount of compression applied, we propose two new methods for enhancing strain image quality, i.e., displacement normalization and adaptive persistence. Both in vitro and in vivo experiments are carried out to acquire ultrasound data and produce strain images in real time under the application of quasi static compression. The experimental results demonstrate that the methods are quite effective in improving strain image quality and thus can be applied to implementing an ultrasound elasticity imaging system that operates in real time.

Decision on Compression Ratios for Real-Time Transfer of Ultrasound Sequences

  • Lee, Jae-Hoon;Sung, Min-Mo;Kim, Hee-Joung;Yoo, Sun-Kwook;Kim, Eun-Kyung;Kim, Dong-Keun;Jung, Suk-Myung;Yoo, Hyung-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.489-491
    • /
    • 2002
  • The need for video diagnosis in medicine has been increased and real-time transfer of digital video will be an important component in PACS and telemedicine. But, Network environment has certain limitations that the required throughput can not satisfy quality of service (QoS). MPEG-4 ratified as a moving video standard by the ISO/IEC provides very efficient video coding covering the various ranges of low bit-rate in network environment. We implemented MPEG-4 CODEC (coder/decoder) and applied various compression ratios to moving ultrasound images. These images were displayed in random order on a client monitor passed through network. Radiologists determined subjective opinion scores for evaluating clinically acceptable image quality and then these were statistically processed in the t-Test method. Moreover the MPEG-4 decoded images were quantitatively analyzed by computing peak signal-to-noise ratio (PSNR) to objectively evaluate image quality. The bit-rate to maintain clinically acceptable image quality was up to 0.8Mbps. We successfully implemented the adaptive throughput or bit-rate relative to the image quality of ultrasound sequences used MPEG-4 that can be applied for diagnostic performance in real-time.

  • PDF

Real-Time Implementation of Medical Ultrasound Strain Imaging System (의료용 초음파 스트레인 영상 시스템의 실시간 구현)

  • Jeong, Mok-Kun;Kwon, Sung-Jae;Bae, Moo-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.101-111
    • /
    • 2008
  • Strain imaging in a medical ultrasound imaging system can differentiate the cancer or tumor in a lesion that is stiffer than the surrounding tissue. In this paper, a strain imaging technique using quasistatic compression is implemented that estimates the displacement between pre- and postcompression ultrasound echoes and obtains strain by differentiating it in the spatial direction. Displacements are computed from the phase difference of complex baseband signals obtained using their autocorrelation, and errors associated with converting the phase difference into time or distance are compensated for by taking into the center frequency variation. Also, to reduce the effect of operator's hand motion, the displacements of all scanlines are normalized with the result that satisfactory strain image quality has been obtained. These techniques have been incorporated into implementing a medical ultrasound strain imaging system that operates in real time.

Contrast Improvement in Diagnostic Ultrasound Strain Imaging Using Globally Uniform Stretching (진단용 초음파 변형률 영상에서 전역 균일 신장에 의한 콘트라스트 향상)

  • Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.504-508
    • /
    • 2010
  • In conventional diagnostic ultrasound strain imaging, when displaying strain image on a monitor, human visual characteristics are utilized such that hard regions are displayed as dark and soft regions are displayed as bright. Thus, hard regions representing tumor or cancer are displayed as dark, decreasing the contrast inside the lesion. Because the lesion area is stiff and thus displayed as dark, a method of inverting the image brightness and thereby increasing the contrast in the lesion for better diagnostic purposes is proposed wherein a postcompression signal is extended in the time domain by a factor corresponding to the reciprocal of the amount of the applied compression using a technique termed globally uniform stretching. Experiments were carried out to verify the proposed method on an ultrasound elasticity phantom with radio-frequency data acquired from a diagnostic ultrasound clinical scanner. It is found that the new method improves the contrast-to-noise ratio by a factor of up to about 1.8 compared to a conventional strain imaging method that employs a reversed gray color map without globally uniform stretching.

Brachial Plexus Injury after Deep Sleep (깊은 수면 이후 발생한 상완신경총 손상)

  • Kwak, Jung Min;Choi, Jun Ho;Park, Dong Yoon
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.44-47
    • /
    • 2019
  • Lying on the side while falling asleep deeply after drinking or taking a sleeping pill can cause compressive neuropathy. We report a 70-year-old male patient of medial cord of left brachial plexus injury (BPI) after deep sleep. The mechanism of the injury might be compression and stretching of brachial plexus. The electrodiagnostic study was performed and the medial cord lesion of BPI was suggested. The ultrasonography image of compression site revealed the nerve swelling of medial cord of brachial plexus and median nerve at the mid-arm level. Pharmacologic treatment including oral prednisolone and exercise training were prescribed. On 6 months after initial visit, neurologic symptom and pain were improved but mild sequelae was remained.

Multiple Transmit Focusing Method With Modified Orthogonal Golay Codes for Ultrasound Imaging (초음파 영상에서 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법)

  • 김배형;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.217-231
    • /
    • 2003
  • Coded excitation with complementary Golay sequences is an effective means to increase the SNR and penetration of ultrasound imaging. in which the two complementary binary codes are transmitted successively along each scan-line, reducing the imaging frame rate by half. This method suffers from low frame rate particularly when multiple transmit focusing is employed, since the frame rate will be further reduced in proportion to the number of focal zones. In this paper. a new ultrasound imaging technique based on simultaneous multiple transmit focusing using modified orthogonal Golay codes is proposed to improve lateral resolution with no accompanying decrease in the imaging frame rate, in which a pair of orthogonal Golay codes focused at two different focal depths are transmitted simultaneously. On receive, these modified orthogonal Golay codes are separately compressed into two short pulses and individually focused. These two focused beams are combined to form a frame of image with improved lateral resolution. The Golay codes were modified to improve the transmit power efficiency (TPE) for practical imaging. Computer simulations and experimental results show that the proposed method improves significantly the lateral resolution and penetration of ultrasound imaging compared with the conventional method.