• Title/Summary/Keyword: Ultrasound examination

Search Result 314, Processing Time 0.028 seconds

Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images (초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석)

  • Hye-Ri, Chun;Hyon-Chol, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2022
  • This study attempted to find out the degree of agreement between ultrasound image findings along with analysis of attenuation index and scatter distribution index values within tissues through quantitative measurement analysis using liver ultrasound images. From August 2022 to October 2022, liver ultrasound was performed on 45 patients who were suspected of having fatty liver and who received a prescription for liver ultrasound. As a result of the study, as a result of analyzing the agreement between the ultrasound image findings and the tissue attenuation index, the Kappa value was 0.82 (p<0.05), showing a very high agreement between the two examination methods. In addition, as a result of the agreement analysis between the ultrasound image findings and the scatter distribution index in the tissue, the Kappa value was 0.642 (p<0.05), showing high agreement between the two examination methods. At the time of fat liver prediction, the use of liver ultrasound findings and quantitative ultrasonography techniques, such as intra-tissue attenuation index and intra-tissue scatter distribution index, may be helpful in determining the degree of progression of fatty liver patients.

Analysis of Job Characteristics for Ultrasound Examination of Radiological Technologists in Yeongnam Area (영남지역 방사선사의 초음파검사 직무특성 분석)

  • Jeong, Bong-Jae;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.639-647
    • /
    • 2022
  • This study analyzed the job characteristics of radiological technologists in charge of ultrasound examinations in the Yeongnam region. The measuring tool used in the study was a questionnaire, and the subjects were radiological technologists in charge of ultrasound examination at medical institutions located in the Yeongnam region from August 01 to November 30, 2021. In consideration of the COVID-19 situation, statistical analysis was performed using the SPSS/PC Ver 18.0 program using e-mail and SNS in a non-face-to-face manner with 158 questionnaires. As a result of analyzing the job characteristics of the radiological technologists in charge of ultrasound examination, the job satisfaction was 3.24±0.61. In the effect of job characteristic factors on job satisfaction, professional position, self-esteem, and trust relationship formation were found to be higher than the average of 3.0. However, as the dissatisfaction factor, compensation and appropriateness of work were cited. Therefore, in order to improve the job characteristics and satisfaction level of radiological technologists in charge of ultrasound examinations, it is necessary to do their best to improve the appropriate work environment of medical institutions and to continuously secure professionalism of radiological technologists in charge of ultrasound examinations.

Clinical Observation on Blood Flow of Facial Acupuncture Points in Bell's Palsy Patients by Doppler Ultrasound (도플러 초음파검사를 이용한 안면마비 환자의 안면부 경혈의 혈류 관찰)

  • Yin, Chang-Shik;Bae, Young-Min;Choi, Yang-Sik;Ko, Jeong-Min;Kim, Sergey;Kang, Uk;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.49-58
    • /
    • 2009
  • Objectives : The aim of this study was to investigate whether Doppler ultrasound device is applicable for the evaluation of facial palsy patients. Methods : A total of 25 patients participated in the first assessment and 22 of them finished a follow-up assessment one week later. An assessment comprised of a Minimax-Doppler-K device examination on bilateral acupoints $ST_5$, $SI_{19}$, $ST_2$, and $BL_1$, House-Brackmann grading, and subjective symptom questionnaire. Measurement reliability was assessed and clinically meaningful variations of Doppler measurement values were explored. Results : Doppler ultrasound examination revealed a significant difference of some measurement values between values of the symptom side and the contralateral side, between groups of severe paralysis and moderate paralysis, and between groups of short duration(0-3 weeks) and long duration (3 weeks-5 months) by non-parametric analyses (p<0.05). Several re-examination values showed a significant correlation with the first examination values by Spearman's correlation tests (p<0.05). Conclusions : This study revealed several possibilities for the clinical application of this device. Further validity tests and device improvements for a user's convenience would be helpful for its practical application.

  • PDF

A Scope of Work of Radiological Technologists for Ultrasound Examinations (초음파검사에 대한 방사선사 업무범위의 법적 고찰)

  • Lim, Chang Seon;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.481-490
    • /
    • 2021
  • There is no qualification system for sonographers in Korea. But the MEDICAL SERVICE TECHNOLOGISTS, ETC. ACT stipulates that radiological technologists can handle ultrasound equipment. However, there is controversy about the scope of the work allowed for radiological technologists to perform ultrasound examinations. Accordingly, the authoritative interpretation of the Ministry of Health and Welfare of Korea, the adjudication of administrative judgment, and the judgment of the courts were analyzed. As a result, the authoritative interpretation expresses that when a radiological technologist performs an ultrasound examination, a diagnosis and specific guidance should be made in real time while the doctor simultaneously watches the radiological technologist's images. In the adjudication of administrative judgment, it was decided that the handling of ultrasound-related equipment was the work of the radiological technologist. The court ruled that it was illegal for a radiological technologist to make a medical judgment on ultrasound examination. In the United States, Canada, etc., the sonographer independently conducts ultrasound examination according to the doctor's prescription, prepares a summary of what they saw and this is passed on to the doctor. Therefore, in Korea, there is a need for institutional improvement so that radiological technologists can perform ultrasound examinations according to doctors' prescriptions without real-time guidance.

A Diagnostic Ultrasound Imaging System (초음파 영상진단장치)

  • Lee, Seong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy (초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구)

  • Hoon Kim;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

Usefulness of Ultrasound for Detecting Suspected Peripheral Nerve Lesions in Diagnosis of Peripheral Neuropathy : Case Report and Brief Review of the Literature

  • Jung, Jae-Hyun;Kim, Kwang-Hai;Choi, Soon-Kyoo;Shim, Jae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.132-135
    • /
    • 2013
  • Ultrasound scanning of a peripheral nerve along its expected course is a simple and useful method for determining the cause of peripheral neuropathy. We present 3 cases of peripheral neuropathy in which the pathology was detected by simple ultrasound scanning of the affected nerve. There were 2 cases of entrapment neuropathy due to mucoid cyst and 1 case of nerve sheath tumor. All lesions were visualized by simple ultrasound scanning of the involved peripheral nerve. Our results suggest that if a lesion affecting the peripheral nerve is suspected after history and physical examination or electrophysiologic studies, ultrasound scanning of the peripheral nerve of interest throughout its course is very helpful for identifying the causative lesion.

Ultrasonographic Diagnosis in the Knee (슬관절에서의 초음파적 진단)

  • Min, Kyoung-Dae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Ultrasound is a first line examination of the knee and useful diagnostic tool in assessing the various knee lesions. The advantages of ultrasound are that it is non-invasive, easily available at bed side, cheap, well accepted by patients, and that it has technical benefits including dynamic evaluation. Its limitations include reliability, which is largely operator dependent and its inability to evaluate deep structures. Technical guidelines of the ultrasound released by European Society of MusculoSkeletal Radiology (ESSR) and ultrasonographic findings of various knee lesions are described.

  • PDF

Nondestructive Examination of Optical Lens by Resonant Ultrasound Spectroscopy (공명초음파 분광법에 의한 광학기기용 렌즈의 비파괴 검사)

  • 김성훈;박상국;김영남;양인영
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.257-262
    • /
    • 2004
  • As optical connectors dominate the performance of optical transmitters or receivers, they need an ultra-precise processing and are composed of optical fibers, ferrule and optical glass lenses. Therefore, this study suggests a nondestructive evaluation technique or a system using resonant ultrasound spectroscopy to evaluate flaws in a optical glass lens. It also conducted a nondestructive evaluation for flaws that are commonly found in a optical glass lens and reviewed the results.

  • PDF

The Effect of Low-intensity Pulsed Ultrasound on Osteogenesis in Mini-pig Mandibles (Mini-pig 하악골에서 저강도진동초음파가 골형성에 미치는 영향)

  • Yun, Yeong-Eun;Lee, Jun;Min, Seung-Ki;Kim, Sang-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.6
    • /
    • pp.467-477
    • /
    • 2011
  • Purpose: The objective of this study was to examine the affected period and the amount of bone formation during osteogenesis of intramembranous bone using low-intensity pulsed ultrasound (LPUS) $in$ $vivo$. Methods: Xeno-bone (Bio-oss) and autogenous bone were grafted bilaterally into mini-pig mandibles. The left mandible served as the control and the other mandible was treated with 3 MHz, 160 mW (output, 0.8 mW) ultrasound stimulation for 7 days 15 minutes per day. The mini-pigs were sacrificed at 1, 2, 4, and 8 weeks, and micro computed tomography (${\mu}CT$), a microscopic examination, and a statistical analysis were performed on the specimens. Results: Based on a computerized image analysis of the ${\mu}CT$ scans, the experimental group had an average 150% more new bone formation than that in the control group. The effect of LPUS continued during the post operative 2 weeks. The histomorphological microscopic examination showed similar results. Conclusion: Our results suggest the LPUS had an effect on early intramembranous bone formation in vivo.