• Title/Summary/Keyword: Ultrasound examination

Search Result 314, Processing Time 0.025 seconds

A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode (초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.213-218
    • /
    • 2017
  • Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different (p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.

The Diagnostic Value of Dynamic US in the Extensor Tendon Dislocation at the Metacarpophalangeal Joint (중수지 관절부 신전건 탈구에서 실시간 표시 초음파의 진단적 가치)

  • Moon, Eun-Sun;Park, Yong-Cheol;Kim, Myung-Sun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Purpose: We studied the diagnostic value of dynamic US in the extensor tendon dislocation at the metacarpophalangeal joint. Materials and Methods: From January 2007 to October, we studied 6 cases that had been diagnosed and followed over 5 months (2-10) in average. US examination using a 10-MHz linear transducer were performed in three cases. The causes of dislocations were traumatic in 5 cases and congenital in one case. Results: In only 3 cases which could not be diagnosed clinically, we performed US. In dynamic US, all three cases showed the extensor tendon dislocation evidently. Operative findings were sagittal band rupture in 4 cases, capsular loosening in one case and sagittal band thinning in one case. Sagittal band repair was performed in 4 cases and capsular augmentation in one case. In case of congenital dislocation showing 4 digital extensor tendon dislocations in right hand, we operated only the second extensor by sagittal band repair with augmentation by looping. At last follow-up, no case showed recurrence or limitation of motion. Conclusion: In case of extensor tendon dislocation without apparent clinical finding, US with dynamic study has so great value that it can detect the dislocation in real time, which is superior to MRI.

  • PDF

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

Usefuless of Ultrasonography Examination in Radial Nerve Palsy Associated with Humerus Fracture - Technical Report - (상완골 골절에 동반된 요골 신경 마비 환자에서 초음파 검사의 유용성 - 술기 보고 -)

  • Lee, Sang-Hyuk;Sung, Chang-Min;Park, Hyung-Bin
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Primary radial nerve palsy occurs in association with approximately 10% of humerus shaft fractures. Secondary radial nerve palsy, which is iatrogenic, occurs in association with approximately 10% to 20% of humerus shaft fractures. Whether the radial nerve palsy is caused primarily by the fracture or secondarily by the surgery, it is necessary to determine whether the radial nerve is being disrupted or compressed by the surrounding structures. This evaluation will dictate whether to await natural recovery or to perform surgical exploration. The current authors report one case of primary radial nerve palsy, due to the humerus fracture, and one case of secondary radial nerve palsy, associated with the osteosynthesis procedure. In both patients, the radial nerve was assessed for anatomical integrity with ultrasonography. Nerve disruption was found in one patient, and a sural nerve graft was performed. Nerve adhesion was found in the other patient, and neurolysis was performed. In both cases, the clinical results were satisfactory. This report focuses on the usefulness of ultrasonography in radial nerve assessment in patients with radial nerve palsy.

  • PDF

Analysis of Risk Factors Affecting Breast Cancer Incidence : Breast Ultrasonography (유방암 발생에 영향을 미치는 위험인자 분석: 유방초음파 검진자 대상으로)

  • An, Hyun;Yang, Sung-Hee;Im, In-Chul;Lee, Jin-soo
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.289-295
    • /
    • 2017
  • In general, a number of studies have been conducted on factors affecting breast cancer development, but systematic investigations of risk factors are rare. The purpose of this study was to investigate the factors involved in breast cancer screening before breast ultrasound diagnosis and the risk factors associated with breast cancer screening by ultrasound. Self-administered questionnaire was performed on 417 patients who underwent breast ultrasonography and classified as benign and malignant. Breast cancer was associated with age, BMI, and type of medication(p<0.05). Multivariate analysis showed that the odds ratio was 4.93 times higher in the 50s compared to the less than 50s, 2.43 times higher in the obese group than in the normal group, 0.14 times and 0.16 times lower in hormonal replacement therapy(p<0.05). Therefore, as age increases, periodical examination of health and appropriate weight management are needed. So this study is expected to provide basic data for identification of risk factors affecting breast cancer development.

A Spleen Size Measured by Ultrasound in 20's Normal Adults (초음파검사에 의한 20대 정상 성인의 비장 크기)

  • Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • An enlarged spleen can be caused by infections, cirrhosis and other liver diseases, blood diseases characterized by abnormal blood cells, problems with the lymph system, immune diseases, or other conditions. Therefore, knowing the normal size of the spleen is helpful for the diagnosis of spleen and may be useful for follow-up. Ultrasonographic examination may be considered normal size if the maximum length is less than 12 cm and less than 5 cm in thickness, but may vary depending on sex and race. We aimed to present the normal range of spleen size by measuring the spleen size by ultrasonography in 20's normal adult Korean. The length of the male spleen was 10.95±1.07 cm and the width was 4.48±0.61 cm. The female length was 9.20±1.30 cm and the width was 3.55±0.44 cm. There was a significant difference (p<0.001). The spleen length increased with increasing height (r=.57) and there was a significant positive linear relationship with increasing spleen length as body weight increased(r=.63). In normal adults, 5 men and 2 women had a spleen length of more than 12 cm and 2 men with a size exceeding 13 cm.

Superovulation Response after Follicular Wave Synchronization with Follicular Aspiration by Ultrasonography in HanWoo I. Effect of Follicular Aspiration on Ovarian Response Following Superovulation (과배란 처치시 우세난포 조절에 의한 한우 수정란 생산성 향상에 관한 연구 I. 우세난포 처리에 따른 난소반응)

  • 이병천;이동원;신수정;박종임;황우석
    • Journal of Embryo Transfer
    • /
    • v.14 no.3
    • /
    • pp.203-210
    • /
    • 1999
  • In this stuyd, the effect of the dominant follicle aspiration for the superovulatory response in HanWoo was investigated. The criterion for the presence or absence of a dominant follicle based on their morphological examination. The dominant follicle was aspirated 48hr before the onset of superovulation treatment by 6.5MHz convex probe connected with a carrier and superovulation induced by FSH (Super-Ov Tyrer, Texas, U.S.A) adminstered twic a day s.c. over 4 day in a decreasing regimen. From 13 HanWoo scanned daily to determine the presence and growth of the dominant follicle, its an average diameter of 15.4mm was measured and an average diameter of corpora lutea was 18.7mm on day of follicular aspiration. In the experiment, a follicular remove by ultrasound-guided aspiration, the ovarian response was significantly enhanced when animals were superovulated in the aspiation of a dominant follicle compare with animals superovulated non-aspiration of a dominat follicle. In the aspiration of a dominant follicle donors yieleded more corpora lutea(14.4$\pm$4.7 vs 8.6$\pm$3.4) and transferable embryos(8.9$\pm$4.2 vs 5.4$\pm$2.7) than control. In cows in which the dominant follicle had been aspirated under sonographical control 2 days before superovuation, the number of corpus lutea and transferable embryos were significantly enhanced compared with animals superovulated in the presence of a dominant follicle (14.4$\pm$4.7 vs 6.9$\pm$2.7, ; 8.9$\pm$4.2 vs 3.3$\pm$1.6). After 7 days of artificial insemination, the embryos at 7 days were cllected by uterine flushing after dominant follicle insemination, the embryos at 7 days were collected by uterine flushing after dominant follicle aspiration and superovulation treatment, and evaluated their quality by morphological criteria. Sixteen embryos with excellent and good grade were transferred into 8 recipient cows. Six pregnancies were identified at 60 and 120 days of gestation by rectal palpations. In conclusion, the present study showed that 1) the presence or absence of a dominant follicle signficicnatly affects superovulatory responses, and 2) ultrasound-guided follicular aspiration of the dominant follicle and superovuation treatment provides an accurate and procedure to increase ovarian responses in HanWoo.

  • PDF

Ultrasonographic Diagnosis of the Patellar Clunk Syndrome after Posterior Stabilized Total Knee Arthroplasty - A Case Report - (후방 안정형 인공 관절 전치환술 후 슬개골 덜컹 증후군의 초음파적 진단 - 증례 보고 -)

  • Yoo, Jae Doo;Kim, Nam Ki;Chung, Jae Yoon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.39-44
    • /
    • 2014
  • The patellar clunk syndrome is one of the patellofemoral complication, caused by formation of the fibrous nodule at the suprapatellar region after total knee arthroplasty. The symptom involves painful catching, crepitus and clunk during knee extension. It has been mainly but not exclusively associated with the posterior stabilized total knee system. The fibrous nodule is entrapped in the femoral intercondylar notch of the femoral component during flexion and as the knee is extended, it displaces back to the trochlear groove abruptly and the typical symptoms occur. The risk of developing this complication is primarily related to the design of the femoral component and higher incidence was noted with earlier designs of posterior stabilized knee prosthesis. Modifications have been made to the femoral component to optimize the kinematics of the patellofemoral joint and thereby reduced the incidence of patellar clunk syndrome but did not eliminate the problem completely. Clinical examination is the gold standard of diagnosis and imaging study has been used as a possible adjunct to diagnosis. Especially ultrasonography is an imaging modality, which can be easily performed to detect the fibrous nodule on the quadriceps tendon. We report a case of patellar clunk syndrome which was diagnosed with ultrasonography.

  • PDF

A Study on the Effectiveness of Hand Sanitizer compared to Conventional Ultrasound Gel during Ultrasound Examination (초음파검사 시 기존 초음파젤과 비교한 손소독제의 유용성 연구)

  • Sun-Youl Seo;Jin-Ok Lee;Young-Ran Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.957-964
    • /
    • 2023
  • This study focused on hand sanitizer as a medium that can replace ultrasonic gel, which is vulnerable to contamination by bacteria that reside on the hand. Hand sanitizer produces a strong sterilization effect from germs resident on the hands through different sterilization principles depending on the ingredients. Select products of gel type, cream type, and foam type, except for liquid type with low viscosity, and ultrasonically apply one 62% ethanol gel type and one cream type, one benzalkonium chloride 0.066% cream type and one foam type, respectively. Using ATS-539 as a medium, image evaluation was performed on the axial and lateral resolution and penetration depth, and the presence or absence of an air layer between the probe and the phantom. As a result, in the evaluation of the axial and lateral resolution and the depth of penetration, all four experimental groups met the evaluation criteria. However, in the case of the foam type, although it was suitable for the evaluation criteria of resolution and penetration depth, dark shadows appeared on both sides except for the center of observation during image evaluation. Through this experiment, it was possible to confirm the possibility that the remaining three types of hand sanitizers except the foam type could replace the ultrasonic gel.

Delayed Cancer Diagnosis in Thyroid Nodules Initially Treated as Benign With Radiofrequency Ablation: Ultrasound Characteristics and Predictors for Cancer

  • Myoung Kyoung Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.903-911
    • /
    • 2023
  • Objective: Regrowth after radiofrequency ablation (RFA) of symptomatic large thyroid nodules, initially treated as benign, sometimes turns out to be malignancies. This study aimed to assess the ultrasound (US) characteristics of thyroid nodules initially treated as benign with RFA and later diagnosed as cancers, predictive factors for cancers masquerading as benign, and methods to avoid RFA in these cancers. Materials and Methods: We reviewed the medical records of 134 consecutive patients with 148 nodules who underwent RFA between February 2008 and November 2016 for the debulking of symptomatic thyroid nodules diagnosed as benign using US-guided biopsy. We investigated the pre-RFA characteristics of the thyroid nodules, changes at follow-up after RFA, and the final surgical pathology. Results: Nodule regrowth after RFA was observed in 36 (24.3%) of the 148 benign nodules. Twenty-two of the 36 nodules were surgically removed, and malignancies were confirmed in seven (19.4% of 36). Of the 22 nodules removed surgically, pre-RFA median volume (range) was significantly larger for malignant nodules than for benign nodules: 22.4 (13.9-84.5) vs. 13.4 (7.3-16.8) mL (P = 0.04). There was no significant difference in the regrowth interval between benign and malignant nodules (P = 0.49). The median volume reduction rate (range) at 12 months was significantly lower for malignant nodules than for benign nodules (51.4% [0-57.8] vs. 83.8% [47.9-89.6]) (P = 0.01). The pre-RFA benignity of all seven malignant nodules was confirmed using two US-guided fine-needle aspirations (FNAs), except for one nodule, which was confirmed using US-guided core-needle biopsy (CNB). Regrown malignant nodules were diagnosed as suspicious follicular neoplasms by CNB. Histological examination of the malignant nodules revealed follicular thyroid carcinomas, except for one follicular variant, a papillary thyroid carcinoma. Conclusion: Symptomatic large benign thyroid nodules showing regrowth or suboptimal reduction after RFA may have malignant potential. The confirmation of these nodules is better with CNB than with FNA.