• 제목/요약/키워드: Ultrasound Scanning

검색결과 100건 처리시간 0.021초

Scanning acoustic microscopy for material evaluation

  • Hyunung Yu
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.25.1-25.11
    • /
    • 2020
  • Scanning acoustic microscopy (SAM) or Acoustic Micro Imaging (AMI) is a powerful, non-destructive technique that can detect hidden defects in elastic and biological samples as well as non-transparent hard materials. By monitoring the internal features of a sample in three-dimensional integration, this technique can efficiently find physical defects such as cracks, voids, and delamination with high sensitivity. In recent years, advanced techniques such as ultrasound impedance microscopy, ultrasound speed microscopy, and scanning acoustic gigahertz microscopy have been developed for applications in industries and in the medical field to provide additional information on the internal stress, viscoelastic, and anisotropic, or nonlinear properties. X-ray, magnetic resonance, and infrared techniques are the other competitive and widely used methods. However, they have their own advantages and limitations owing to their inherent properties such as different light sources and sensors. This paper provides an overview of the principle of SAM and presents a few results to demonstrate the applications of modern acoustic imaging technology. A variety of inspection modes, such as vertical, horizontal, and diagonal cross-sections have been presented by employing the focus pathway and image reconstruction algorithm. Images have been reconstructed from the reflected echoes resulting from the change in the acoustic impedance at the interface of the material layers or defects. The results described in this paper indicate that the novel acoustic technology can expand the scope of SAM as a versatile diagnostic tool requiring less time and having a high efficiency.

초음파를 이용한 한우의 조기임신진단에 관한 연구 (Studies on Early Pregnancy Diagnosis in Korean Native Cattle by Ultrasonography)

  • 전병준;윤기영;이은송;이우근;이병천;황우석
    • 한국수정란이식학회지
    • /
    • 제11권3호
    • /
    • pp.291-300
    • /
    • 1996
  • Real time B-mode ultrasound was used to detect the early conceptus in 187 Korean native cattles between days 10 and 60 after last insemination. The ultrasound diagnostic findings were systemically confirmed by palpation per rectum after the 60th day of last insemination. The embryonic vesicle and the embryo proper within the veside were first visible on mean day fl and 23, respectively. The heartbeat of the embryo proper could be detected on day 26, and the limb buds, placentomes, amnion, fetal movement, umbilical cord, optic area and split hooves were first visible on day 33, 34, 34, 44.5, 45, 32 and 48, respectively. The mean length of embryo proper was 3.8mm on day 23 which later increased to 56. 6rnrn on day 60. When ultrasound was used to detect the conceptus between days 20 and 30 after insemination and palpation per rectum after the 60th day of insemination, the accuracy rates of pregnancy detection by ultrasound scanning at days 20, 22, 24, 26, 28, 30 were 44.4, 69.2, 78.6, 87.5, 90.0, 93.3%. In summary, the early pregnancy diagnosis of Korean native cattle with ultrasound appears high accuracy rates. It is considered that ultrasound can be used in veterinary practice well.

  • PDF

집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정 (Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices)

  • 도일;조주형;김성목;백경민;김용태;박승민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

전국 소동물 병원의 초음파 진단기기 및 활용도 현황조사 (Survey on Utilization of Ultrasonographic Machine in Small Animal Clinics in South Korea)

  • 장진화;백민지;장동우
    • 한국임상수의학회지
    • /
    • 제28권4호
    • /
    • pp.408-414
    • /
    • 2011
  • This study was carried out to analyze the utilization of ultrasound machines in animal hospitals and focused on surveying the present condition of diagnostic ultrasound on veterinary medicine in South Korea. Total 279 veterinary hospitals were surveyed with e-mail questionnaires or telephone survey. E-mail questionnaires consist of 17 items of questions including existence of ultrasound machine, types of ultrasound machine, ultrasound examination costs, frequency, purposes, other diagnostic imaging equipments, and referring system of ultrasound. Telephone surveys asked about the existence of the ultrasound machine and types of the ultrasound machine to 279 animal hospitals. Two hundred and seventy-one out of 279 animal hospitals holds ultrasound machine. Seventy-two percents clinics purchased used ultrasonographic machines and mean years after the date of manufacture is 7.5 years and the proportion of superannuated machines are relatively high. Also many clinicians prefer single organ scanning rather than general scan technique and more than 60% of clinics perform ultrasonographic examination less than 5 times a week. Clinics located in Seoul area tend to have more expensive and brand-new ultrasonographic machines and the distribution of radiology specialist are higher in this area. Problems associated with the present condition were oversupply of machines, unequal distribution of the medical equipment in different localities, ineffective use of the medical equipment, and high percentage of old poor-quality medical equipments. There should be a viable alternative proposal to control amount and quality of the ultrasound machines. Also, the improved management system for the ultrasound machine is required.

Estimation of Genetic Correlations and Selection Responses for Carcass Traits between Ultrasound and Real Carcass Measurements in Hanwoo Cows

  • Son, Jihyun;Lee, Deukhwan
    • Journal of Animal Science and Technology
    • /
    • 제55권6호
    • /
    • pp.501-508
    • /
    • 2013
  • This study was conducted to determine genetic correlations among carcass traits measured by ultrasound and real carcass measurements and to estimate indirect selection responses for real carcass traits based on ultrasound measurements in Hanwoo cows. To accomplish this, 22,080 ultrasound measurement records from 17,926 cows collected from 2001 to 2012 and 11,907 carcass records obtained from fattened cattle from 2008 to 2012 were used. Genetic parameters were estimated based on eye muscle area (EMA), backfat thickness (BF) and marbling score (MS) measured by ultrasound-scanning of live cows and using the official technique on chilled bovine half-carcasses after slaughtering. Heritability and genetic correlation for carcass traits were estimated using a mixed model equation that consisted of environmental effects as fixed parameters and additive genetic effects and residual effects as random parameters, assuming that traits were different between ultrasound and carcass measurements. This statistical method was applied to the average information restricted maximum likelihood method. The heritability of EMA, BF and MS measured by ultrasound were 0.33, 0.61 and 0.46, respectively, while the heritability estimates of the corresponding traits based on carcass measurements were 0.29, 0.40 and 0.38, respectively and the genetic correlation between ultrasound and carcass traits for EMA, BF and MS were 0.41, 0.78 and 0.67, respectively. The genetic correlation between ultrasound and carcass traits was highly positive. Additionally, the selection response for marbling score was estimated to be 0.42 per generation if the cows were selected based on the ultrasound scan marbling score with an assumed selection intensity of 0.8. Overall, these results indicate that the ultrasound scan technique would be applicable to judging cow selection for genetically improved meat quality.

Development of an Objective Structured Clinical Examination Checklist and a Post-Education Questionnaire for Musculoskeletal Ultrasound Training Focusing on Volar Wrist and Carpal Tunnel Syndrome

  • Cho, Eunbyul;Han, Young-Min;Kang, Yeonseok;Kim, Jae-Hyo;Shin, Min-Seop;Oh, Myungjin;Jung, Hyun-Jong;Jeon, Hyesoo;Cho, Nam Geun;Leem, Jungtae
    • Journal of Acupuncture Research
    • /
    • 제39권2호
    • /
    • pp.105-114
    • /
    • 2022
  • Background: The objective structured clinical examination (OSCE) is used in the colleges of Korean Medicine, but few studies have validated the OSCE evaluation criteria or post-education questionnaires. Diagnostic ultrasound is used in Korean medicine treatment including acupuncture, acupotomy, and pharmacopuncture to increase the safety and efficacy of treatment. We aimed to develop and validate a OSCE checklist and questionnaire for diagnostic musculoskeletal ultrasound training. Methods: A OSCE checklist and rubric for diagnostic ultrasound training, and questionnaire was developed using literature research. Eight expert panelists verified each draft item in a single-round survey. Items with a content validity ratio (CVR) < 0.75 were excluded or modified to reflect the experts' opinions. Results: The OSCE checklist and rubric for diagnostic ultrasound training focusing on volar wrist and carpal tunnel syndrome included: 15 items revised according to CVR and expert opinions, the pre-examination procedure, structures to be identified by ultrasound, scans with 2 diagnostic criteria for carpal tunnel syndrome, an explanation of the exam results, and the post exam procedure. The questionnaire consisted of 15 items, including the overall evaluation of training, the effect of the OSCE, and the perception of the ultrasound. All 6 self-evaluation items were not revised, as they had a CVR of ≥ 0.75. Conclusion: An ultrasound OSCE for scanning the volar wrist and diagnosing carpal tunnel syndrome was developed using 15 validated tasks, 15 survey questions about ultrasound training, and 6 questions for self-evaluation. These results may be used in the future for education in diagnostic ultrasound.

ULTRASOUND가 근관벽의 도말층제거에 미치는 영향에 관한 주사전자현미경적 연구 (SCANNING ELECTRON MICROSCOPIC STUDY OF THE EFFECT OF ULTRASOUND IN THE REMOVAL OF THE SMEAR LAYER FROM THE ROOT CANAL WALL)

  • 윤승섭;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.167-180
    • /
    • 1991
  • The purpose of theis study was to evaluate the effectiveness of ultrasonic instrumentation in removing debris and smear layer from the root canal walls. 54 extracted, permanent single rooted teeth were randomly divided into 6 groups of 9 teeth. After canal preparation, the teeth were longitudinally sectioned. The sepcimens were then naturally dried for 2 days, given a maximun thickness gold coating, and examined under the SEM (JSM-35C type, JAPAN). Photographs of all specimens were then taken of the middle and the apical third of the root canal wall. The results were as follows: 1. In all groups, debris and the smear layer were not completely removed from the canal wall 2. There were no significant differences between at the apical third and at the middle third in removing debris and the smear layer in all groups. 3. There were no significant difference between the step - back group and the ultrasound group in removing debris and smear layer. 4. In general, the step - back/ultrasonund groups showed greater canal debridement than the step - back group or ultrasound group. 5. The step - back/ultrasound group with a No. 25 file for 3 min. showed significantly greater canal debridement than the step-back group (p<0.05), or the other step - back/ultrasound groups(p<0.05).

  • PDF

HIFU: 현황 및 기술적 동향 (High Intensity Focused Ultrasound for Cancer Treatment: Current Agenda and the Latest Technology Trends)

  • 서종범
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.55-63
    • /
    • 2010
  • High Intensity Focused Ultrasound (HIFU) is a noninvasive surgical method mainly targeting deeply located cancer tissue. Ultrasound is generated from an extemally located transducer and the beam is focused at the target volume, so that selective damage can be achieved without harm to overlying or surrounding tissues. The mechanism for cell killing can be combination of thermal and cavitational damage. Although cavitation can be an effective means of tissue destruction, the possibility of massive hemorrhage and the unpredictable nature of cavitational events prevent clinical application of cavitation. Hence, thermal damage has been a main focus related to HIFU research. 2D phased array transducer systems allow electronic scanning of focus, multi-foci, and anti-focus with multi-foci, so that HIFU becomes more applicable in clinical use. Currently, lack of noninvasive monitoring means of HIFU is the main factor to limit clinical applications, but development in MRI and Ultrasound Imaging techniques may be able to provide solutions to overcome this problem. With the development of advanced focusing algorithm and monitoring means, complete noninvasive surgery is expected to be implemented in the near future.

3차원 의료기기용 초음파진단기 프로브 개발 (Development of a Ultrasound Probe for 3-D Ultrasonic Imaging)

  • 박종수;김성래;남윤수
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.