• Title/Summary/Keyword: Ultrasound Scan

Search Result 133, Processing Time 0.033 seconds

Treatment of giant iatrogenic pseudoaneurysm of the femoral artery (대퇴동맥에 발생한 의인성 거대 가성동맥류에 대한 치료)

  • Kang, Wu-Seong;Park, Chan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.423-428
    • /
    • 2019
  • The role of angioembolization has increased because of increases in nonoperative treatment for traumatic splenic injury. We report here a case of successful treatment of iatrogenic pseudoaneurysm of the femoral artery by thrombin injection with coil embolization. A 55-year-old female was admitted to our hospital because of blunt trauma. Computed tomography (CT) revealed a grade V splenic injury with contrast extravasation; therefore, angioembolization was performed. Three days after admission, follow-up CT scan revealed rebleeding from the spleen, and repeat angioembolization was performed. Seven days after admission, an approximately $7.0cm{\times}4.0cm-sized$ pseudoaneurysm was found on follow-up CT scan and there was no bleeding from the spleen. Although thrombin was injected into the aneurysmal sac, there was still inflow of blood, as observed on color-doppler ultrasound. Therefore, coil embolization to the neck of the aneurysm was performed. On angiography, there was no contrast filling into the sac. The size of the pseudoaneurysmal sac had decreased on follow-up CT scan, and the patient was discharged to home without complications. We successfully treated a giant pseudoaneurysm of the femoral artery using thrombin and coil embolization.

Intraoperative Measurement and Analysis of Coronary Artery Bypass Graft Flow (수술중 측정한 관상동맥 우회도관 혈류량의 분석)

  • Park, Kye-Hyun;Chae, Hurn;Yun, Yang-Ku;Lee, Jae-Woong;Kim, Kwhan-Mien;Jun, Tae-Gook;Kim, Jhin-Gook;Shim, Young-Mog;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.760-769
    • /
    • 1997
  • This study aimed to determine factors that influence blood flow through coronary bypass grafts and to analyze relationship between the graft flow and postoperative outcome. Blood flow through 146 bypass grafts(GBF) was measured with transit-time ultrasound flowmeter during coronary artery bypass grafting operations in 50 patients. Single and multiple regression analyses were done for relationships between the GBF and four variables: internal diameter of recipient coronary artery, myocardial value of bypassed branch(es), type of graft, and finding of preoperative myocardial perfusion scan. The relationship between GBF and postoperative scan finding was also analyzed. 1. The mean GBF was significantly higher in sequential grafts than in single vein grafts or in internal thoracic artery grafts(61.5 vs. 46.9 and 42.5 ml/min). 2. Myocardial value and recipient artery diameter were found to be the factors determining GBF. There was no correlation between GHF and presence of perfusion defect in the preoperative scan. 3. Myocardial value was found to be more important than recipient artery diameter in determinintg GBF. 4. Reversible perfusion defects were more frequently found in the areas upplied by grafts with low GBP. But this fact had only mild statistical significance. These results suggest that blood flow through a bypass graft is more determined by the size of its supplyinf: myocardium than by the size of recipient artery. So, we can expect effective improvement in myocardial flow reserve after grafting of small(1~1.5mm) coronary arteries, if they supply substantial area of myocardium.

  • PDF

Development of a Laser-Generated Ultrasonic Inspection System by Using Adaptive Error Correction and Dynamic Stabilizer (적응적 에러 보정과 다이나믹 안정기를 이용한 레이저 유도 초음파 검사 시스템 개발)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Park, Moon-Cheol;Lim, Chang-Hwan;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.391-399
    • /
    • 2005
  • Laser-generated ultrasonic inspection system is a non-contact scanning inspection device with high spatial resolution and wide bandwidth. The amplitude of laser-generated ultrasound is varied according to the energy of pulse laser and the surface conditions of an object where the CW measuring laser beam is pointing. In this paper, we correct the generating errors by measuring the energy of pulse laser beam and correct the measuring errors by extracting the gain information of laser interferometer at each time. h dynamic stabilizer is developed to stably scan on the surface of an object for an laser-generated ultrasonic inspection system. The developed system generates ultrasound after adaptively finding the maximum gain time of an laser interferometer and processes the signal in real time after digitization with high speed. In this paper, we describe hardware configuration and control algorithm to build a stable laser-generated ultrasonic inspection system. Also, we confirmed through experiments that the proposed correction method for the generating errors and measuring errors is effective to improve the performance of a system.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.

Radiologic Evaluation of Intraabdomenal Masses in Childhood (소아복부 종괴의 방사선학적 고찰)

  • Kwon, Hyuk-Po;Byun, Woo-Mok;Hwang, Mi-Soo;Kim, Sun-Yang;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1988
  • The abdominal tumors in children are different from those of adult. These tumors are the third most common one, preceded by leukemia and brain tumors, in children under 15 years. X-ray examination is the most important method among diagnostic approaches. The role of diagnostic imaging is to identify the precise anatomic location and extent of pathologic process with the minimal number of imaging procedures. 23 cases of abdominal tumors were reviewed in respect of age incidence, site of origin, radiologic findings. The results are briefly summarized as follows : 1. Neuroblastoma was the most common(6 cases) and wi1m's tumor(5 cases), choledocal cyst(4 cases), ovarian mass(3 cases), hydronephrosis(2 cases), were descending order in frequency. 2. The most common site was retroperitoneum(60%). Kidney was the single most common site of origin. 3. Radiologic findings. The most common findings of plain radiography was ill defined soft tissue mass and this method was helpful in the presence of calcification especially in neuroblastoma. Ultrasonographic pattern was anechoic(cystic), echoic or mixed pattern, but this method provide less precise anatomical details, nevertheless ultrasonography wes paticullary useful imaging modality for the pediatric abdominal tumors. IVP findings were renal displacement, caliceopelvic system distortion or nonvisualization of kidney, these information was helpful in determining the location of tumors. CT scan showed homogenous or inhomogenous, cystic or solid, mass with their anatomic location. 4. Ultrasonography was the most widely used specific diagnostic method, but had limited value in detecting the anatomic location of tumors. CT scan was superior to ultrasound for determining the extent of tumors.

  • PDF

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

Pattern of Ovulation in Korean Women with Premature Ovarian Failure (한국인 조기난소부전 여성의 배란양상)

  • Kim, Hye-Min;Kim, Jae-Ryoung;Choi, Eun-Joo;Park, Eun-Joo;Hong, Seo-Yu;Lee, Jin-Yong;Park, Won-Il
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • Objective: Significant portion of premature ovarian failure patients ovulate intermittently and even can achieve pregnancy. The clinical features and reproductive potentials of Korean women with premature ovarian failure have never been elucidated. The purpose of this study is to assess ovarian follicular growth and ovulatory potential. Methods: Complete medical records of fifteen women with idiopathic premature ovarian failure were reviewed retrospectively. Subjects with more than 6 ultrasonographic scans and 36 months of follow-up period were included. Once the ovarian follicle was found by ultrasonography, the follicular growth was serially monitored. The result of ovulation induction of 6 cycles in 4 patients were also evaluated. Rate of positive ovarian follicle by ultrasound, rate of natural follicular growth and response of ovulation induction were assessed. Results: Among the 15 patients, 6 women (40%) had ovarian follicle in random ultrasonography. But the chance of positive follicle per ultrasonography scan was 7% (8 out of 115 scans). One out of 6 women eventually ovulated during the follow-up scan. In remaining 5 subjects, size of follicles remained unchanged. None of 6 ovulation induction cycles resulted successful ovulation. Conclusion: Incidence of positive ovarian follicle in Korean premature ovarian failure patients is lower than that of Western counterpart. This result, however, could not be directly compared because of the differences of study design. The ovulation rate by medical ovulation induction in this group is 0%, which is worse than the reported success rate of Western studies.

The Role of Chest CT Scans in the Management of Empyema (농흉에서 전산화 단층촬영의 의의)

  • Heo, Jeong-Suk;Kwun, Oh-Yong;Sohn, Jeong-Ho;Choi, Won-Il;Hwang, Jae-Seok;Han, Seung-Beom;Jeon, Young-June;Kim, Jung-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.397-404
    • /
    • 1994
  • Background: To decide the optimal antibiotics and application of chest tube, examination of pleural fluid is fundamental in the management of empyema. Some criteria for drainage of pleural fluid have been recommended but some controversies have been suggested. Recently, newer radiologic methods including ultrasound and computed tomography scanning, have been applied to the diagnosis and management of pleural effusions. We undertook a retrospective analysis of 30 patients with pleural effusion who had CT scans of the chest in order to apply the criteria of Light et al retrospectively to patients with loculation and to correlate the radiologic appearance of pleural effusions with pleural fluid chemistry. Method: We analyzed the records of 30 out of 147 patients with pleural effusion undergoing chest CT scans. Results: 1) Six of the pleural fluid cultures yielded gram negative organisms and three anaerobic bacterias and one Staphylococcus aureus and one non-hemolytic Streptococci. No organism was cultured in ninteen cases(63.0%). 2) The reasons for taking chest CT scans were to rule out malignancy or parenchymal lung disease(46.7%), poor response to antibiotics(40.0%), hard to aspirate pleural fluid(10.0%) and to decide the site for chest tube insertion(3.3%). 3) There was no significant correlations between ATS stages and loculation but there was a tendency to loculate in stage III. 4) There was a significant inverse relationship between the level of pH and loculation(p<0.05) but there appeared to be no relationship between pleural fluid, LDH, glucose, protein, loculation and pleural thickening. 5) In 12 out of 30, therapeutic measures were changed according to the chest CT scan findings. Conclusion: We were unable to identify any correlations between the plerual fluid chemistry, ATS stages and loculations except pH, and we suggest that tube thoracotomy should be individualized according to the clinical judgement and serial observation. All patients with empyema do not need a chest CT scan but a CT scan can provide determination of loculation, guiding and assessing therapy which should decrease morbidity and hospital stay.

  • PDF

A Study on a Crack Evaluation Technique for Turbine Blade Root Using Phased Array Ultrasonics (위상배열 초음파를 이용한 터빈 블레이드 루트부내 결함평가 기법 연구)

  • Cho, Yong-Sang;Jung, Gye-Jo;Park, Sang-Ki;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.151-157
    • /
    • 2004
  • Ultrasonic testing is a kind of nondestructive test to detect a crack or discontinuity in materials or on material surfaces by sending ultrasound to it. This conventional ultrasonic technique has some limitations in reliably detecting crack or accurately assessing materials in the case of complex-shaped power plant components such as a turbine blade root. An alternative method for such a difficult inspection is highly needed. In this study, application of a phased array ultrasonic testing (UT) system to a turbine blade, one of the critical power plant components, has been considered, and the particular incident angle has been determined so that the greatest track detectability and the most accurate crack length evaluation nay be achieved. The response of ultrasonic phased array was also analyzed to establish a special method to determine the track )ength without moving the transducer. The result showed that the developed method for crack length assessment is a more accurate and effective method, compared with the conventional method.