• Title/Summary/Keyword: Ultrasound Medical Imaging

Search Result 277, Processing Time 0.024 seconds

Multiple Transmit Focusing Method With Modified Orthogonal Golay Codes for Ultrasound Imaging (초음파 영상에서 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법)

  • 김배형;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.217-231
    • /
    • 2003
  • Coded excitation with complementary Golay sequences is an effective means to increase the SNR and penetration of ultrasound imaging. in which the two complementary binary codes are transmitted successively along each scan-line, reducing the imaging frame rate by half. This method suffers from low frame rate particularly when multiple transmit focusing is employed, since the frame rate will be further reduced in proportion to the number of focal zones. In this paper. a new ultrasound imaging technique based on simultaneous multiple transmit focusing using modified orthogonal Golay codes is proposed to improve lateral resolution with no accompanying decrease in the imaging frame rate, in which a pair of orthogonal Golay codes focused at two different focal depths are transmitted simultaneously. On receive, these modified orthogonal Golay codes are separately compressed into two short pulses and individually focused. These two focused beams are combined to form a frame of image with improved lateral resolution. The Golay codes were modified to improve the transmit power efficiency (TPE) for practical imaging. Computer simulations and experimental results show that the proposed method improves significantly the lateral resolution and penetration of ultrasound imaging compared with the conventional method.

Review of outcomes of using lower ethanol concentration (83%) in percutaneous ultrasound-guided renal cyst sclerotherapy in dogs

  • Sanghyeon Yoon;Jungmin Kwak;Deokho Im;Hakyoung Yoon
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.61.1-61.12
    • /
    • 2023
  • Background: Percutaneous renal cyst sclerotherapy (PRCS) as a treatment for renal cysts is usually performed with a high concentration of ethanol (≥ 90%). This study reviewed cases in which a lower concentration of ethanol (83%) was used for the procedure in dogs. Methods: Records of cases of renal cysts treated by sclerotherapy using 83% ethanol in dogs were reviewed. Outcomes of the treatment were evaluated by comparing volumes of renal cysts before the procedure and the volumes after treatment, using ultrasound images with the volume reduction rates classified as follows: < 50% of initial volume (failed); ≥ 50% but < 80% of initial volume (partial success); ≥ 80% but < 95% of initial volume (great success); ≥ 95% of initial volume (complete success). Results: Out of nine dog kidneys, renal cysts sclerotherapy with 83% ethanol achieved partial success in one kidney, great success in four, and complete success in the other four. No side effect was observed. The mean of the volume-reduction rates was 90.00 ± 11.00 while the minimum and maximum reduction rates were 65% and 100%, respectively. Conclusions: The lower ethanol concentration (83%) is good for disinfecting kidneys in PRCS.

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.

Ultrasound Imaging Improvement using Higher Harmonics of Impluse Sound (고조파음원에 의한 초음파영상의 해상도 개선)

  • Chang, Jee-Won;Yang, Jeong-Won;Kim, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.4
    • /
    • pp.292-300
    • /
    • 1993
  • Acoustical imaging has made brilliant progress in the medical science field, and has also made much progress in the nondestructive testing and under water acoustics applications since doctor Dussik brother has studied about possibilities of making images of brain by recording variations in the intensity of ultrasonic beam from head in 1937. In this paper an acoustical image is reconstructed with the power spectra analysed by impulse ultrasound wave generated by electrodynamic transducer(EDT). The EDT generates the impulse ultrasound of 77KHz in center frequency and 120KHz in bandwidth at -20dB by 1200V exciter in this experiment. The impulse ultrasound has the dominant frequency components of 47KHz, 177KHz, 110KHz and 155KHz. The U shape object is adopted in making an acoustical image. The resulted spectral acoustical images are different from the optical view of the U shape object. However the image reconstructed from 110KHz spectrum is very similar to the original optical shape of the object. Even KHz level impulse sound of 70$\mu$sec pulse width is found to be useful in reconstructing acoustical imaging improvement.

  • PDF

Efficacy and Safety of Ultrasound-Guided Radiofrequency Ablation for Primary Hyperparathyroidism: A Prospective Study

  • Hui-hui Chai;Yu Zhao;Zeng Zeng;Rui-zhong Ye;Qiao-hong Hu;Hong-feng He;Jung Hwan Baek;Cheng-zhong Peng
    • Korean Journal of Radiology
    • /
    • v.23 no.5
    • /
    • pp.555-565
    • /
    • 2022
  • Objective: To assess the efficacy and safety of ultrasound (US)-guided radiofrequency ablation (RFA) in patients with primary hyperparathyroidism (PHPT). Materials and Methods: This prospective study enrolled 39 participants (14 male, 25 female; mean age, 59.5 ± 15.3 [range, 18-87] years) between September 1, 2018, and January 31, 2021. All participants had parathyroid lesions causing PHPT, proven biochemically and through imaging. The imaging features of the PHPT nodules, including the shape, margin, size, composition, and location, were evaluated before treatment. Serum intact parathyroid hormone, calcium, and phosphorus levels; parathyroid nodule volume; and PHPT-related symptoms were recorded before and after treatment. We calculated the technical success, biochemical cure, and clinical cure rates for these patients. Complications were evaluated during and after the ablation. Results: Complete ablation was achieved in 38 of the 39 nodules in the 39 enrolled participants. All the patients were treated in one session. The technical success rate was 97.4% (38/39). The mean follow-up duration was 13.2 ± 4.6 (range, 6.0-24.9) months. At 6 and 12 months post-RFA, the biochemical cure rates were 82.1% (32/39) and 84.4% (27/32), respectively, and the clinical cure rates were 100% (39/39) and 96.9% (31/32), respectively. Only 2.6% (1/39) of the patients had recurrent PHPT. At 1, 3, 6, and 12 months after technically successful RFA, 44.7% (17/38), 34.3% (12/35), 15.8% (6/38), and 12.5% (4/32) of participants, respectively, had elevated eucalcemic parathyroid hormone levels. Recurrent laryngeal nerve paralysis occurred in 5.1% (2/39) of the patients, who recovered spontaneously within 1-3 months. Conclusion: US-guided RFA was effective and safe for PHPT patients. RFA may be an alternative treatment tool for patients who cannot tolerate or refuse to undergo surgery.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

Computed tomography and magnetic resonance imaging features of suspected transitional cell carcinoma lesions involving the bladder, prostate, and urethra in a dog: a case report

  • Wooseok Jin;Sang-Kwon Lee;Seulgi Bae;Taeho Oh;Kija Lee
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.4
    • /
    • pp.39.1-39.5
    • /
    • 2023
  • A 14-year-old, spayed female, poodle was presented with dysuria and hematuria. A mass that appeared hypoechoic on ultrasound and hypoattenuating on computed tomography (CT) extended from the bladder neck to the urethra. Magnetic resonance imaging (MRI) showed the mass invading the muscular layer of the bladder, urethra, and prostate with distinct margins. Transitional cell carcinoma (TCC) was confirmed with the CADET-BRAF test. This study describes the CT and MRI features of suspected TCC lesions involving the bladder, prostate, and urethra. MRI showed superior soft tissue contrast resolution, enabling evaluation of invasion of the muscular layer of the bladder and urethra.

Medical Image Compression using Adaptive Subband Threshold

  • Vidhya, K
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.499-507
    • /
    • 2016
  • Medical imaging techniques such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) and Ultrasound (US) produce a large amount of digital medical images. Hence, compression of digital images becomes essential and is very much desired in medical applications to solve both storage and transmission problems. But at the same time, an efficient image compression scheme that reduces the size of medical images without sacrificing diagnostic information is required. This paper proposes a novel threshold-based medical image compression algorithm to reduce the size of the medical image without degradation in the diagnostic information. This algorithm discusses a novel type of thresholding to maximize Compression Ratio (CR) without sacrificing diagnostic information. The compression algorithm is designed to get image with high optimum compression efficiency and also with high fidelity, especially for Peak Signal to Noise Ratio (PSNR) greater than or equal to 36 dB. This value of PSNR is chosen because it has been suggested by previous researchers that medical images, if have PSNR from 30 dB to 50 dB, will retain diagnostic information. The compression algorithm utilizes one-level wavelet decomposition with threshold-based coefficient selection.

Survey on Utilization of Ultrasonographic Machine in Small Animal Clinics in South Korea (전국 소동물 병원의 초음파 진단기기 및 활용도 현황조사)

  • Chang, Jin-Hwa;Paik, Min-Ji;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.408-414
    • /
    • 2011
  • This study was carried out to analyze the utilization of ultrasound machines in animal hospitals and focused on surveying the present condition of diagnostic ultrasound on veterinary medicine in South Korea. Total 279 veterinary hospitals were surveyed with e-mail questionnaires or telephone survey. E-mail questionnaires consist of 17 items of questions including existence of ultrasound machine, types of ultrasound machine, ultrasound examination costs, frequency, purposes, other diagnostic imaging equipments, and referring system of ultrasound. Telephone surveys asked about the existence of the ultrasound machine and types of the ultrasound machine to 279 animal hospitals. Two hundred and seventy-one out of 279 animal hospitals holds ultrasound machine. Seventy-two percents clinics purchased used ultrasonographic machines and mean years after the date of manufacture is 7.5 years and the proportion of superannuated machines are relatively high. Also many clinicians prefer single organ scanning rather than general scan technique and more than 60% of clinics perform ultrasonographic examination less than 5 times a week. Clinics located in Seoul area tend to have more expensive and brand-new ultrasonographic machines and the distribution of radiology specialist are higher in this area. Problems associated with the present condition were oversupply of machines, unequal distribution of the medical equipment in different localities, ineffective use of the medical equipment, and high percentage of old poor-quality medical equipments. There should be a viable alternative proposal to control amount and quality of the ultrasound machines. Also, the improved management system for the ultrasound machine is required.

Effective Adaptive Dynamic Quadrature Demodulation in Medical Ultrasound Imaging

  • Yoon, Heechul;Jeon, Kang-won;Lee, Hyuntaek;Kim, Kyeongsoon;Yoon, Changhan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.468-475
    • /
    • 2018
  • In medical ultrasound imaging, frequency-dependent attenuation downshifts and reduces a center frequency and a frequency bandwidth of received echo signals, respectively. This causes considerable errors in quadrature demodulation (QDM), result in lowering signal-to-noise ratio (SNR) and contrast resolution (CR). To address this problem, adaptive dynamic QDM (ADQDM) that estimates center frequencies along depth was introduced. However, the ADQDM often fails when imaging regions contain hypoechoic regions. In this paper, we introduce a valid region-based ADQDM (VR-ADQDM) method to reject the misestimated center frequencies to further improve SNR and CR. The valid regions are regions where the center frequency decreases monotonically along depth. In addition, as a low-pass filter of QDM, Gaussian wavelet based dynamic filtering was adopted. From the phantom experiments, average SNR improvements of the ADQDM and the VR-ADQDM over the traditional QDM were 1.22 and 5.27 dB, respectively, and the corresponding maximum SNR improvements were 2.56 and 10.58 dB. The contrast resolution of the VR-ADQDM was also improved by 0.68 compared to that of the ADQDM. Similar results were obtained from in vivo experiments. These results indicate that the proposed method would offer promises for imaging technically-difficult patients due to its capability in improving SNR and CR.