• 제목/요약/키워드: Ultrasound Measures

Search Result 72, Processing Time 0.03 seconds

Association of Polymorphisms in the Bovine Leptin Gene with Ultrasound Measurements for Improving in Korean Cattle

  • Kong, H.S.;Oh, J.D.;Lee, S.G.;Hong, Y.S.;Song, W.I.;Lee, S.J.;Kim, H.C.;Yoo, B.H.;Lee, H.K.;Jeon, G.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.12
    • /
    • pp.1691-1695
    • /
    • 2006
  • The identification method that inflects real time ultrasound (RUT) and the potential application of marker assisted selection (MAS) for improvement of a cow population of Hanwoo (Korean Native cattle) was studied. The averages of RUT longissimus muscle area, RUT fat thickness, and RUT marbling score scanned at the 13th rib were 55.78 $cm^2$, 3.70 mm and 3.83 scores, respectively. We investigated the effects of the two SNPs (Kpn2 I and Msp I) in the leptin gene on carcass traits for Hanwoo cows by using ultrasound measurements. Genotype CC of the Kpn2 I had a significantly higher effect on back fat thickness (4.23 mm) and longissimus muscle area (57.57 $cm^2$) than genotype TT (3.14 mm, 53.93 $cm^2$, respectively, p<0.05). Genotype AA of the Msp I had a significantly higher effect only on marbling score (5.37) than genotype AB (3.57, p<0.05) and BB (3.37, p<0.05). Significant effects of SNPs in the leptin gene were found for the ultrasound measures of body composition in live cattle.

Manufacture and Image Characteristic Changes Observation by Temperature of Ultrasound Tissue Mimicking Phantom (초음파 Tissue Mimicking 팬텀의 제작과 온도 변화에 따른 영상 특성 변화 관찰)

  • Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.157-161
    • /
    • 2016
  • The purpose of this study is that in measures the acoustic propagate characteristics and temperature sensitivity of ultrasound tissue mimicking phantom(TM phantom). TM phantom manufacture according to the International Electronical Committee(IEC) guidelines for acoustic propagate characteristics of soft tissue. TM phantom was observed to have the image brightness and the image depth penetration decreases changes convergence which was the subject of ultrasound image characteristics in accordance with an external temperature that the change is reduced in temperature below $22^{\circ}C$. This study provide a basis t o create another TM Phantom and TM Phantom has been determined that it is appropriate for use in more than $22^{\circ}C$.

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Relationship Between Ultrasonic and Carcass Measures for Meat Qualities in Hanwoo Steers (한우 거세우에 있어서 생체단층조사기법에 의한 육질판정과 도축 육질 측정치와의 관계)

  • Kim, H. C.;Lee, D. H.;Choi, S. B.;Jeon, G. J.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.183-190
    • /
    • 2003
  • Data from live animal real time ultrasound (RTU) measures from 127 Hanwoo steers were used to assess nutritional physiology and relationship between RTU measures and real carcass measures represented meat quality. Traits considered were longissimus muscle area, fat thickness, and marbling score imaged and scanned using RTU by month and those of carcass measures at about 24 month of age. On this study, increasing pattern for longissimus muscle area would be closely related to growth pattern (p<0.01) and it of fat thickness would be related to quadratic effect of ages. Marbling score would be related to aging, that is, individual deviates of scores were distinctly characterized after 17 mo. even though they were started at about 11 mo. Correlation estimates between RTU measures and corresponding carcass traits were over 0.6 after 17 month of age for all traits considered and these estimates were high as 0.90 after 22 month of age. From this study, Real-time ultrasound measurement would be valuable after 15-17 mo. and measures at about 22 mo. would be helpful to decide age for slaughtering. To utilize these techniques for beef cattle breeding via progeny testing program, 15 mo. RTU measures would be efficiency rather than 12 mo. of other beef breeds. Further study to find genetic variation of RTU measures was needed to utilize these technologies for beef breeding.

The Study of Asymmetrical Contraction of the Lateral Abdominal Muscles in Stroke Patients Using Ultrasound Imaging (초음파 영상을 통한 뇌졸중 환자의 외측복부근 근수축의 비대칭성 연구)

  • Park, Hyun-Ju;Oh, Duck-Won;Shin, Won-Seob
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.3
    • /
    • pp.319-327
    • /
    • 2012
  • Purpose : This study aimed to identify the asymmetry observed in the rehabilitative ultrasound imaging of lateral abdominal muscle thickness and performance between the affected and unaffected side during the abdominal drawing-in maneuver (ADIM), an exercise used to facilitate activation of selectively TrA to stabilize the trunk prior to limb movement. Methods : The Participants were twenty one patients with post-stroke hemiplegia in this study. Ultrasound imaging was used to measure amount of changes in thickness of the external oblique (EO), internal oblique (IO), transversus abdominis (TrA). A Paired t-test was used to compare relaxed muscle thickness to contracted muscle thickness of all 3 muscles between the affected and unaffected sides. Results : The outcome measures included side to side differences of absolute thickness, contraction ratio among the lateral abdominal muscles. There was no significantly difference in between the affected and unaffected side at rest. But, there was a significantly difference in absolute muscle thickness between the affected and unaffected side of only TrA muscle. Also contraction ratio was a significantly difference between the affected and unaffected TrA muscle. Conclusion : These findings support the asymmetrical activation of TrA muscle during abdominal muscle contraction in patients with post-stroke hemiplegia. Further studies are warranted for confirming this outcome.

A Nonparametric Procedure for Bioassay by using Conditional Quantile Processes

  • Kim, Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.3
    • /
    • pp.179-186
    • /
    • 1996
  • Bioequivanence models arise typically in bioassays when new preparations are compared against standard ones by means of responses on some biological organisms. Relative potency measures provide nice interpretations for such bioequivalence and their estimation constitutes the prime interest of such studies. A conditional quantile process based on the k-nearest neighbor method is proposed for this purpose. An alternative procedure based on Kolmogrov-Smirnov type estimator has also been considered along with. ARIC ultrasound data are analyzed as examples.

  • PDF

Prediction of the Dependence of Phase Velocity on Porosity in Cancellous Bone

  • Lee, Kang-Il;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2E
    • /
    • pp.45-50
    • /
    • 2008
  • In recent years, quantitative ultrasound (QUS) technologies have played a growing role in the diagnosis of osteoporosis. Most of the commercial bone somometers measure speed of sound (SOS) and/or broadband ultrasonic attenuation (EUA) at peripheral skeletal sites. However, the QUS parameters are purely empirical measures that have not yet been firmly linked to physical parameters such as bone strength or porosity. In the present study, the theoretical models for wave propagation in cancellous bone, such as the Biot model, the stratified model, and the modified Biot-Attenborough (MBA) model, were applied to predict the dependence of phase velocity on porosity in cancellous bone. The optimum values for the input parameters of the three models in cancellous bone were determined by comparing the predictions with the previously published measurements in human cancellous bone in vitro. This modeling effort is relevant to the use of QUS in the diagnosis of osteoporosis because SOS is negatively correlated to the fracture risk of bone, and also advances our understanding of the relationship between phase velocity and porosity in cancellous bone.

Ultrasonographic findings of the normal diaphragm: thickness and contractility

  • Seok, Jung Im;Kim, Shin Yeop;Walker, Francis O.;Kwak, Sang Gyu;Kwon, Doo Hyuk
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.131-135
    • /
    • 2017
  • Background: Neuromuscular ultrasound can be used to assess the diaphragm. Before it can be used clinically, the reference ranges of diaphragm thickness and contractility must be determined. Methods: We measured the thickness of the diaphragm and the diaphragmatic thickening fraction (DTF) in 80 healthy volunteers with ultrasound and collected their demographic information to determine if age, sex, and body mass index (BMI) influence these measures. Results: The thickness of the diaphragm at resting end expiration was $0.193{\pm}0.044cm$ on the right side and $0.187{\pm}0.039cm$ on the left. The DTF was $104.8{\pm}50.6%$ on the right side and $114.9{\pm}49.2%$ on the left. Sex, weight, height, and BMI significantly affected the thickness of the diaphragm, but had little effect on the DTF. Conclusions: Normal reference values for the diaphragm should be helpful when evaluating the diaphragm. The DTF appears more useful than resting diaphragm thickness because it is affected less by individual variation.

A Comparison of Various Exercises for Scapular Stabilization (견갑골 안정화를 위한 다양한 운동의 비교연구)

  • Kim, Myungjin;Lee, Yujin;Kim, Jihyuk;Bae, Wonsik
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.3
    • /
    • pp.51-62
    • /
    • 2013
  • PURPOSE : This study of 20 healthy male subjects by applying various scapular stabilization exercise to compared Serratus anterior and lower trapezius is change in ultrasound images. METHOD : Thirty healthy subjects voluntarily participated in this study. Ultrasound imaging was recorded from the increasing the activity of Serratus anterior(SA) and Lower trapezius(LT) muscles using Push-up plus, Wall slide, Scapular plane shoulder elevation with resistance exercise. Thickness changes in the Serratus anterior(SA) and lower trapezius(LT) muscles between the relaxed and contracted states in the each exercises. To identify statistical significance, one-way ANOVA with repeated measures was used with the significance level of .05. RESULT : The results of this study were as follows : 1) There were statistically significant difference in thickness changes in the Serratus anterior(SA) and lower trapezius(LT) muscles between the relaxed and contracted states in the each exercises. 2) The Scapular plane shoulder elevation with resistance is more effective to Strengthening in the scapular stabilization muscles than Push up-plus and Wall slide. CONCLUSION : The Scapular plane shoulder elevation with resistance may be used to effectively that patient with various shoulder pain.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.