• Title/Summary/Keyword: Ultrasound Intensity

Search Result 224, Processing Time 0.025 seconds

Ultrasound-guided erector spinae plane block for pain management after gastrectomy: a randomized, single-blinded, controlled trial

  • Jeong, Heejoon;Choi, Ji Won;Sim, Woo Seog;Kim, Duk Kyung;Bang, Yu Jeong;Park, Soyoon;Yeo, Hyean;Kim, Hara
    • The Korean Journal of Pain
    • /
    • v.35 no.3
    • /
    • pp.303-310
    • /
    • 2022
  • Background: Open gastrectomy causes severe postoperative pain. Therefore, we investigated the opioid-sparing effect of the ultrasound-guided bilateral erector spinae plane block (ESPB) after open gastrectomy. Methods: Adult patients undergoing open gastrectomy were randomly assigned to either the ESPB group (ESPB + fentanyl based intravenous patient-controlled analgesia [IV-PCA]) or a control group (fentanyl based IV-PCA only). The primary outcome was total fentanyl equivalent consumption during the first 24 hour postoperatively. Secondary outcomes were pain intensities using a numeric rating scale at the post-anesthesia care unit (PACU) and at 3, 6, 12, and 24 hour postoperatively, and the amount of fentanyl equivalent consumption during the PACU stay and at 3, 6, and 12 hour postoperatively, and the time to the first request for rescue analgesia. Results: Fifty-eight patients were included in the analysis. There was no significant difference in total fentanyl equivalent consumption during the first 24 hour postoperatively between the two groups (P = 0.471). Pain intensities were not significantly different between the groups except during the PACU stay and 3 hour postoperatively (P < 0.001, for both). Time to the first rescue analgesia in the ward was longer in the ESPB group than the control group (P = 0.045). Conclusions: Ultrasound-guided ESPB did not decrease total fentanyl equivalent consumption during the first 24 hour after open gastrectomy. It only reduced postoperative pain intensity until 3 hour postoperatively compared with the control group. Ultrasound-guided single-shot ESPB cannot provide an efficient opioid-sparing effect after open gastrectomy.

Comparative Evaluation of Filters for Speckle Noise Reduction in a Clinical Liver Ultrasound Image (간 초음파 영상에서의 스페클 노이즈 제거를 위한 필터들의 비교 평가)

  • Hajin Kim;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.475-484
    • /
    • 2023
  • This study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the filter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.

A Prospective Study on the Value of Ultrasound Microflow Assessment to Distinguish Malignant from Benign Solid Breast Masses: Association between Ultrasound Parameters and Histologic Microvessel Densities

  • Ah Young Park;Myoungae Kwon;Ok Hee Woo;Kyu Ran Cho;Eun Kyung Park;Sang Hoon Cha;Sung Eun Song;Ju-Han Lee;JaeHyung Cha;Gil Soo Son;Bo Kyoung Seo
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.759-772
    • /
    • 2019
  • Objective: To investigate the value of ultrasound (US) microflow assessment in distinguishing malignant from benign solid breast masses as well as the association between US parameters and histologic microvessel density (MVD). Materials and Methods: Ninety-eight breast masses (57 benign and 41 malignant) were examined using Superb Microvascular Imaging (SMI) and contrast-enhanced US (CEUS) before biopsy. Two radiologists evaluated the quantitative and qualitative vascular parameters on SMI (vascular index, morphology, distribution, and penetration) and CEUS (time-intensity curve analysis and enhancement characteristics). US parameters were compared between benign and malignant masses and the diagnostic performance was compared between SMI and CEUS. Subgroup analysis was performed according to lesion size. The effect of vascular parameters on downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4A masses was evaluated. The association between histologic MVD and US parameters was analyzed. Results: Malignant masses were associated with a higher vascular index (15.1 ± 7.3 vs. 5.9 ± 5.6), complex vessel morphology (82.9% vs. 42.1%), central vascularity (95.1% vs. 59.6%), penetrating vessels (80.5% vs. 31.6%) on SMI (all, p < 0.001), as well as higher peak intensity (37.1 ± 25.7 vs. 17.0 ± 15.8, p < 0.001), slope (10.6 ± 11.2 vs. 3.9 ± 4.2, p = 0.001), area (1035.7 ± 726.9 vs. 458.2 ± 410.2, p < 0.001), hyperenhancement (95.1% vs. 70.2%, p = 0.005), centripetal enhancement (70.7% vs. 45.6%, p = 0.023), penetrating vessels (65.9% vs. 22.8%, p < 0.001), and perfusion defects (31.7% vs. 3.5%, p < 0.001) on CEUS (p ≤ 0.023). The areas under the receiver operating characteristic curve (AUCs) of SMI and CEUS were 0.853 and 0.841, respectively (p = 0.803). In 19 masses measuring < 10 mm, central vascularity on SMI was associated with malignancy (100% vs. 38.5%, p = 0.018). Considering all benign SMI parameters on the BI-RADS assessment, unnecessary biopsies could be avoided in 12 category 4A masses with improved AUCs (0.500 vs. 0.605, p < 0.001). US vascular parameters associated with malignancy showed higher MVD (p ≤ 0.016). MVD was higher in malignant masses than in benign masses, and malignant masses negative for estrogen receptor or positive for Ki67 had higher MVD (p < 0.05). Conclusion: US microflow assessment using SMI and CEUS is valuable in distinguishing malignant from benign solid breast masses, and US vascular parameters are associated with histologic MVD.

Effect of Low Intensity Sound Wave on UC-MSC(Umbilical Cord Mesenchymal Stem Cell Growth (저강도 음파 조사가 중간엽 줄기세포 증식에 미치는 영향)

  • Kim, Sung-Min;Kang, Seung-Ho;Jeong, Jae-Hoon;Park, Jung-Keug;Kim, Soo-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.521-525
    • /
    • 2011
  • It is known that the low-intensity sound stimulation really affect to grow the cell. The cellular growth mechanism, however, does not been clearly identified even the effect on the low-intensity sound stimulation. The purpose of this study is to investigate the effect of low-intensity sound stimulation on the alveolar UC-MSC proliferation. Before the low-intensity sound stimulation is applied, the UC-MSC are cultured for 24 hours to facilitate their attachments. The cells are divided into two groups. And each was exposed to a medium with or without the low-intensity ultrasound stimulation at 71dB intensity level. The UC-MSC are again divided into three treatment groups of group 1, 2, and 3 and exposed to a frequency at 50Hz, 100Hz, and 1000Hz, respectively. In the results, it is investigated that the growth rates of UC-MSC for the stimulated groups were higher than those of control groups. In 1000Hz frequency, the number of UC-MSC cell is significantly higher than control groups (p>0.05). We would put the hypothesis that the cell growth could be enhanced by an appropriate low-intensity sound stimulation.

Submucosal Tumor Analysis of Endoscopic Ultrasonography Images (내시경 초음파 영상의 점막하 종양 분석)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1044-1050
    • /
    • 2010
  • Endoscopic ultrasonography is a medical procedure in endoscopy combined with ultrasound to obtain images of the internal organs. It is useful to have a predictive pathological manifestation since a doctor can observe tumors under mucosa. However, it is often subjective to judge the degree of malignant degeneration of tumors. Thus, in this paper, we propose a feature analysis procedure to make the pathological manifestation more objective so as to improve the accuracy and recall of the diagnosis. In the process, we extract the ultrasound region from the image obtained by endoscopic ultrasonography. It is necessary to standardize the intensity of this region with the intensity of water region as a base since frequently found small intensity difference is only to be inefficient in the analysis. Then, we analyze the spot region with high echo and calcium deposited region by applying LVQ algorithm and bit plane partitioning procedure to tumor regions selected by medical expert. For detailed analysis, features such as intensity value, intensity information included within two random points chosen by medical expert in tumor region, and the slant of outline of tumor region in order to decide the degree of malignant degeneration. Such procedure is proven to be helpful for medical experts in tumor analysis.

Feature Analysis of Endoscopic Ultrasonography Images (내시경 초음파 영상의 특징 분석)

  • Kim, kwang-beak;Kang, hyo-joo;Kim, mi-jeong;Kim, gwang-ha
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.390-397
    • /
    • 2009
  • Endoscopic ultrasonography is a medical procedure in endoscopy combined with ultrasound to obtain images of the internal organs. It is useful to have a predictive pathological manifestation since a doctor can observe tumors under mucosa. However, it is often subjective to judge the degree of malignant degeneration of tumors. Thus, in this paper, we propose a feature analysis procedure to make the pathological manifestation more objective so as to improve the accuracy and recall of the diagnosis. In the process, we extract the ultrasound region from the image obtained by endoscopic ultrasonography. It is necessary to standardize the intensity of this region with the intensity of water region as a base since frequently found small intensity difference is only to be inefficient in the analysis. Then, we analyze the spot region with high echo and calcium deposited region by applying LVQ algorithm and bit plane partitioning procedure to tumor regions selected by medical expert. For detailed analysis, features such as intensity value, intensity information included within two random points chosen by medical expert in tumor region, and the slant of outline of tumor region in order to decide the degree of malignant degeneration. Such procedure is proven to be helpful for medical experts in tumor analysis.

  • PDF

Measurement of sonoluminescence intensity for evaluation of the amount of radical generated by ultrasonic cavitation (초음파 캐비테이션에 의해 생성되는 라디칼의 발생량 평가를 위한 소노루미네센스 발광강도의 측정)

  • Jungsoon Kim;Moojoon Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.50-56
    • /
    • 2023
  • The hydroxyl radical (·OH) and superoxide anion radical (·O2- ) generated by the shock wave generated during ultrasonic cavitation collapse in TiO2 suspension are highly useful because they can sterilize and disinfect. For practical use as a sterilization method without any chemicals, in this study, we proposed a method for evaluating the generation of radicals generated by high-intensity ultrasound emitted to titanium dioxide suspension. In the proposed method, the sonoluminescence phenomenon, which emits light by ultrasonic cavitation decay energy, was utilized, and the degree of radical generation was evaluated through the amount of light energy by sonoluminescence. As a result, even at a low concentration of titanium dioxide of 0.02 wt%, light energy 5 times higher than in the absence of titanium dioxide was received. After that, as the concentration increased by 0.1 wt%, the luminous intensity of sonoluminescence increased linearly by about 14.8 × 10-12 lm. Therefore, it was confirmed that the radicals generated by radiating high-intensity ultrasound to the titanium dioxide suspension increased linearly as the concentration of titanium dioxide increased within a given concentration range.

The Effect of Ultrasound Irradiation on the Neural Cell Adhesion Molecules(NCAM) Expression in Rat Spinal Cord after the Sciatic Nerve Crush Injury (초음파가 흰쥐의 좌골신경 압좌손상 후 척수내 Neural Cell Adhesion Molecules의 발현에 미치는 영향)

  • Kim, Hyun-Ae;Han, Jong-Man
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.41-55
    • /
    • 2007
  • Purpose: This study aimed to compare the effect on nerve regeneration of ultrasound irradiation in rats with peripheral nerve injury. Methods: To investigate alterations of the NCAM immunoreactivity in non-crushed part and crushed part of the spinal cord, the unilateral sciatic nerve of the rats were crushed. The expression of NCAM was used as the marked of peripheral nerve regeneration, and also plays an important role in developing nerve system. Experimental animals were sacrificed by perfusion fixation at post-injury 1, 3, 7, 14 days after ultrasound irradiation. The pulsed US was applied at a frequency of 1MHz and a spatial average-temporal average Intensity of 0.5W/of (20% pulse ratio) for 1 mins. The Luxol fast blue-cresyl violet stain were also done to observe the morphological changes. Results: Alteration of NCAM immunoreactivity in the crushed part and the non-crushed part of lower lumbar spinal cord were observed. NCAM-immunoreactivity cells were some increased in the dorsal horn lamina I, III and cell ventral horn at 1 day after unilateral sciatic nerve injury. However, there was not significant difference in the relationship between crushed part and non-crushed part. NCAM-inmmunoreactivity was remarkably increased at 3 days after unilateral sciatic nerve injuryin the gray matter and white matter. NCAM-immunoreactivity was increased in the ventral horn and post horn of experimental crushed part. Also, NCAM-immunoreactivity in large motor neurons in ventral horns lamina VIII, IX were increased at 7 days after unilateral sciatic nerve injury. At 14 days after sciatic nerve crushed injury, there was no significant difference. All group were decreased for 14 days. In the time course of NCAM expression, all groups showed a significant difference at 3day groups(p<0.05). Whereas, CC group was noted a significant difference between 3day and 7 day group respectively. In NCAM expression, there were significantly increased in all group. In the relationship between CNC group and ENC group, significant difference was detected among 3, 7, 14 day group(p<0.05). The difference between CC group and ENC group were noted in all groups(p<0.05). Conclusion: It is consequently suggested that the effects of the ultrasound irradiation may increase the NCAM immunoreactive neurons and glial cell in the spinal cord after unilateral sciatic nerve crushed injury. Therefore, the increased NCAM immunoreactivity in the spinal cord may reflect the neuronal damage and healing process induced by a ultrasound irradiation after peripheral nerve injury in rat.

  • PDF

The Effects of Low-Intensity Ultrasound and Laser on Healing of Bone Fracture (저강도 레이저와 초음파의 동시 적용이 골절 치유 촉진에 미치는 효과)

  • Lee, Hyun-Kee
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.331-372
    • /
    • 2003
  • The purpose of study was to evaluate effects of low-intensity ultrasound and laser on healing of bone fracture. Twenty fracture patient were selected for this study(fourteen males, six females. mean aged 44.8) fracture area was humerus, tibia, forearm bones. The obtain result are as follows. 1. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in male(P<.001). 2. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in female(P<.001). 1. The result of this study were following that pain score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 4. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in male between age(P<.001). 5. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in female between age (P<.001). 6. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in male(P<.001). 7. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in female(P<.001). 8. The result of this study were following that radiologic score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 9. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in male between ages(P<.001). 10. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in female between ages(P<.001). 11. The result of this study were following that healing on fracture area was observed that reduced pre intervention compared with post intervention

  • PDF