• 제목/요약/키워드: Ultrasound Imaging

검색결과 657건 처리시간 0.033초

초음파 진단영상 대조도 개선을 위한 확률 경계 맵을 이용한 연구 (A method for ultrasound image edge enhancement by using Probabilistic edge map)

  • 최우혁;박원환;박성윤
    • 대한한의진단학회지
    • /
    • 제20권1호
    • /
    • pp.37-44
    • /
    • 2016
  • Ultrasonic imaging is the most widely modality among modern imaging device for medical diagnosis. Nevertheless, medical ultrasound images suffer from speckle noise and low contrast. In this paper, we propose probabilistic edge map for ultrasound image edge enhancement using automatic alien algorithm. The proposed method used applied speckle reduced ultrasound imaging for edge improvement using sequentially acquired ultrasound imaging. To evaluate the performance of method, the similarity between the reference and edge enhanced image was measured by quantity analysis. The experimental results show that the proposed method considerably improves the image quality with region edge enhancement.

의료용 초음파 B-모드 영상을 위한 신호처리 (Signal Processing in Medical Ultrasound B-mode Imaging)

  • 송태경
    • 비파괴검사학회지
    • /
    • 제20권6호
    • /
    • pp.521-537
    • /
    • 2000
  • 초음파 영상은 의료진단을 위한 영상기기 중 가장 널리 쓰이고 있는 방법으로 전자공학에 있어서 DSP 및 VLSI 분야의 기술발전에 힘입어 보다 효율적이고 복잡한 기법들의 적용이 가능하여져 90년대에 이르러 시스템의 성능이 매우 빠르게 발달되었다. 본 논문은 의료진단용 초음파 영상장치에서 사용되는 주요 디지털 신호처리 기법과 시스템 구현 기술에 대하여 기술하였다. 구체적으로는 일반적인 초음파 영상장치의 구조 및 신호처리 기법을 소개하고, 90년대에 개발된 디지털 초음파 영상장치의 기술적인 내용을 그 기술 동향과 전망과 함께 다루었다. 특히 초음파 영상의 화질을 결정하는 가장 중요한 요소인 해상도를 증대하기 위한 모든 초음파 집속 기법을 표현할 수 있는 통합 합성 구경 모형을 제시하고, 이론적인 해석을 통하여 초음파 영상을 위한 어레이 신호처리 기법들을 구분하고 각 방법들에 대한 특성을 조사하였나. 본 논문에서 소개된 신호처리 기법들은 초음파를 이용한 비파괴 검사 분야에 유용하게 적용될 수 있는 것 들이다.

  • PDF

초음파 영상을 위한 직교 상보수열의 설계 (Design of Mutually Orthogonal Polyphase Complementary Sequences for Ultrasound Imaging)

  • 김배형;김태호;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.393-396
    • /
    • 2002
  • In this paper, we present a new method for generating a set of complementary sequences that can be simultaneously transmitted and yet compressed into a short pulse on reveive, and its application to ultrasound imaging. This new complementary sequences can be designed based on a filter bank theory. The new complementary sequences can be used to improve the SNR of ultrasound imaging without sacrificing the spatial resolution and frame rate, compared to conventional pulse-echo imaging. Computer simulations are performed to verify the proposed method.

  • PDF

초음파 영상을 이용한 고강도 집중 초음파 빔 시각화 (High-intensity focused ultrasound beam path visualization using ultrasound imaging)

  • 송재희;장진호;유양모
    • 한국음향학회지
    • /
    • 제39권1호
    • /
    • pp.16-23
    • /
    • 2020
  • 고강도 집중 초음파(High-Intensity Focused Ultrasound, HIFU) 치료에서 HIFU 초점의 효과적인 위치 파악은 안전한 치료 계획을 개발하는 데 중요하다. 자기 공명 영상 유도 HIFU(Magnetic Resonance Imaging guided HIFU, MRIgHIFU)는 HIFU 초점을 영상화하여 치료 중에 초음파 경로를 시각화 할 수 있지만 초음파 이미징 유도 HIFU(Ultrasound imaging guided HIFU, USIgHIFU)에서는 어려움이 있다. 본 연구에서는 USIgHIFU에 대해 HIFU 초점을 영상화할 수 있는 실시간 초음파 빔 시각화 기법을 제시 하였다. 제안 된 방법에서, 음향 강도(Ispta < 720 mW/㎠) 아래의 이미징 초음파 변환자의 동일한 중심 주파수를 갖는 짧은 펄스가 HIFU 변환기를 통해 전송되고, HIFU 빔 경로를 시각화하기 위해 수신 신호는 동적 수신 포커싱 및 후속 에코 처리를 거쳤다. 소 혈청 알부민 젤 팬텀을 이용한 생체외 실험으로부터, HIFU 빔 경로는 낮은 음향 강도 (Ispta = 94.8 mW/㎠)에서도 명확히 영상화 할 수 있었고 HIFU 초점은 손상이 생성되기 전에 성공적으로 시각화하였다. 이 결과는 제안 된 초음파 빔 경로 시각화 방법이 USIgHIFU 치료에서 원치 않는 조직 손상을 최소화하면서 실시간으로 HIFU 초점을 영상화하는 데 사용될 수 있음을 나타낸다.

신경회로망과 다소자 초음파 트랜스듀스에 의한 수중물체의 화상화 (Object imaging in the water by neural network and multi-element ultrasound transducer)

  • 김응규
    • 전자공학회논문지S
    • /
    • 제35S권1호
    • /
    • pp.80-87
    • /
    • 1998
  • In this study, a multi-element ultrasound transducer has been developed aiming at basic experiment of three-dimension endovascular ultrasound endscopy for clinical diagnos, and experimental results of two-dimensional object imaging in the water are presented by the ultrasound tranducer and neural network. Each ultrasound echo received by thirty-six angular transducer elements is inputed to the eural network, and then backpropagation is used as a learning algorithm. A three-layer artificial neural network is used for learning and imaging of targetw placed in front of the transducer. The object shape of imaging is restricted to rectangular shapes by considering experimental restraint conditions. As a result, rough visualization can be realized even for objects with unlearned shapes through the training by primitive patterns of a various sized rectangular targets.

  • PDF

Quantification of Nerve Viscosity Using Shear Wave Dispersion Imaging in Diabetic Rats: A Novel Technique for Evaluating Diabetic Neuropathy

  • Feifei Liu;Diancheng Li;Yuwei Xin;Fang Liu;Wenxue Li;Jiaan Zhu
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.237-245
    • /
    • 2022
  • Objective: Viscoelasticity is an essential feature of nerves, although little is known about their viscous properties. The discovery of shear wave dispersion (SWD) imaging has presented a new approach for the non-invasive evaluation of tissue viscosity. The present study investigated the feasibility of using SWD imaging to evaluate diabetic neuropathy using the sciatic nerve in a diabetic rat model. Materials and Methods: This study included 11 diabetic rats in the diabetic group and 12 healthy rats in the control group. Bilateral sciatic nerves were evaluated 3 months after treatment with streptozotocin. We measured the nerve cross-sectional area (CSA), nerve stiffness using shear wave elastography (SWE), and nerve viscosity using SWD imaging. The motor nerve conduction velocity (MNCV) was also measured. These four indicators and the histology of the sciatic nerves were then compared between the two groups. The performance of CSA, SWE, and SWD imaging in distinguishing the two groups was assessed using receiver operating characteristic (ROC) analysis. Results: Nerve CSA, stiffness, and viscosity in the diabetic group was significantly higher than those in the control group (all p < 0.05). The results also revealed a significantly lower MNCV in the diabetic group (p = 0.005). Additionally, the density of myelinated fibers was significantly lower in the diabetic group (p = 0.004). The average thickness of the myelin sheath was also lower in the diabetic group (p = 0.012). The area under the ROC curve for distinguishing the diabetic neuropathy group from the control group was 0.876 for SWD imaging, which was significantly greater than 0.677 for CSA (p = 0.030) and 0.705 for SWE (p = 0.035). Conclusion: Sciatic nerve viscosity measured using SWD imaging was significantly higher in diabetic rats. The viscosity measured using SWD imaging performed well in distinguishing the diabetic neuropathy group from the control group. Therefore, SWD imaging may be a promising method for the evaluation of diabetic neuropathy.

초음파 의료영상에서 컴파운딩 기법을 이용한 초음파의 평균 음속도의 측정과 음속도 영상의 구현 (Measurement of the Average Speed of Ultrasound and Implementation of Its Imaging Using Compounding Technique in Medical Ultrasound Imaging)

  • 정목근;권성재;최민주
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권3호
    • /
    • pp.233-240
    • /
    • 2009
  • Using a spatial compound imaging technique in a medical ultrasound imaging system, the average speed of sound in a medium of interest is measured, and imaging of its distribution is implemented. When the brightness reaches the highest level in an ultrasonic image obtained as the speed of sound used in focusing is varied, it turns out that the focusing has been accomplished satisfactorily and that the speed of sound which has been adopted becomes the sought-after average speed of sound. Because spatial compound imaging provides many different views of the same object, the adverse effect of erroneous speed-of-sound estimation tends to be more severe in compound imaging than in plain B-mode imaging. Thus, in compound imaging, the average speed of sound even in the case of speckled images can be accurately estimated by observing the brightness change due to different speeds of sound employed. Using this new method that offers spatial diversity, we can construct an image of the speed of sound distribution in a phantom embedded with a 10-mm diameter plastic cylinder whose speed of sound is different from that of the background. The speed of sound in the cylinder is found to be different from that of the surrounding medium.

역투사 알고리듬과 비촛점 트랜스듀서를 적용한 광음향 단층영상 장치개발과 팬텀실험 (Phantom Evaluation and Development of Photoacoustic Tomography Imaging System using Unfocused Ultrasound Transducer and Back-Projection Algorithm)

  • 유상훈;김도현;송철규
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2349-2351
    • /
    • 2010
  • Photo Acoustic Tomography (PAT) is a hybrid imaging modality which combines high contrast of optical imaging and spatial resolution of ultrasound imaging, thus it is suitable to image biological tissue noninvasively. Laser-induced photoacoustic signals were measured from a sample by means of an unfocused ultrasound transducer, then PAT image was reconstructed based on a universal back-projection algorithm. To evaluate the feasibility of our system, phantom test was performed, consequently, the PAT images obtained using our system showed highly analogous shape and volume with those of the phantom. This result demonstrated that our system can provide a powerful tool for imaging the substructure of biological tissue in non-invasive manner.

고주파수 초음파 영상을 위한 저잡음·광대역 수신 시스템 구현 (Implementation of low-noise, wideband ultrasound receiver for high-frequency ultrasound imaging)

  • 문주영;이준수;장진호
    • 한국음향학회지
    • /
    • 제36권4호
    • /
    • pp.238-246
    • /
    • 2017
  • 고주파수, 고해상도 초음파 영상을 획득하기 위해서는 고주파수 초음파 변환기가 가지는 작은 구경에 따른 낮은 민감도와 침투 깊이에 따른 높은 감쇠량을 극복하여야 한다. 이는 고주파수 초음파 변환기의 본질적인 한계점이므로 수신 시스템을 통하여 그 한계점을 극복하여야 한다. 본 논문은 고주파수, 고해상도 초음파 영상을 위하여 고주파수 초음파 변환기의 본질적인 한계인 낮은 민감도와 높은 감쇠량을 극복할 수 있는 저잡음 광대역 수신 시스템 개발과 특성 평가 결과에 관한 것이다. 개발한 저잡음 광대역 수신 시스템은 80 MHz 이상의 동작 주파수 대역에서 최대 73 dB의 증폭 이득과 48 dB의 가변 이득 범위를 만족하며 ${\pm}1dB$의 증폭 이득 평탄도 성능을 가진다. 또한 개발한 수신 시스템은 상용 리시버에 비하여 8.4 dB 이상의 신호대잡음비 성능과 3.7 dB 이상의 대조도 성능이 우수함을 확인하였다.

정상근과 근막 유발점이 활성화된 근육의 초음파 영상의 비교 (Comparison of Ultrasonography Images on Normal Muscle and Myofascial Trigger Points Activated Muscle)

  • 김명훈;김수현;김현진
    • The Journal of Korean Physical Therapy
    • /
    • 제25권2호
    • /
    • pp.76-80
    • /
    • 2013
  • Purpose: The objective of this study was to offer primary clinical data examining whether change of imaging structure and quantitative evaluation of muscle activity on myofascial trigger points can lead to implementation of an analytical technique for evaluation of myofascial pain diagnoses. In addition, we examined the effect of a variety of mediation techniques, in order to examine neuromuscular physiological characteristics of myofascial trigger points muscle by comparing differences in pressure pain threshold and ultrasound imaging. Methods: Participants in the study included 30 adults in their twenties. The subjects were divided into the normal and myofascial trigger points groups. Clinical outcomes were evaluated by pressure pain threshold for pain and ultrasound imaging was performed for evaluation of the structural characteristics of muscle. Independent t-test was used for statistical analysis. Results: The two groups showed statistical significance in the change in pressure pain threshold (p<0.05). Findings of ultrasound imaging analysis showed no significant differences, increased muscle thickness was observed (p>0.05). Findings of ultrasound imaging analysis showed significant differences, increased muscle echodensity was observed (p<0.05). Findings on ultrasound imaging analysis showed significant differences, increased muscle white area index was observed (p<0.05). Conclusion: From these results, active myofascial trigger points muscle showed quality deterioration on ultrasound imaging. Thorough evaluation of imaging structure and physiological characteristics can be useful quantitative analytical techniques for diagnosis of myofascial pain syndrome and a primary factor reflected in physical therapy intervention.