• Title/Summary/Keyword: Ultrasound Imaging

검색결과 657건 처리시간 0.024초

Ultrasound-guided interventions for controlling the thoracic spine and chest wall pain: a narrative review

  • Park, Donghwi;Chang, Min Cheol
    • Journal of Yeungnam Medical Science
    • /
    • 제39권3호
    • /
    • pp.190-199
    • /
    • 2022
  • Ultrasound-guided injection is useful for managing thoracic spine and chest wall pain. With ultrasound, pain physicians perform the injection with real-time viewing of major structures, such as the pleura, vasculature, and nerves. Therefore, the ultrasound-guided injection procedure not only prevents procedure-related adverse events but also increases the accuracy of the procedure. Here, ultrasound-guided interventions that could be applied for thoracic spine and chest wall pain were described. We presented ultrasound-guided thoracic facet joint and costotransverse joint injections and thoracic paravertebral, intercostal nerve, erector spinae plane, and pectoralis and serratus plane blocks. The indication, anatomy, Sonoanatomy, and technique for each procedure were also described. We believe that our article is helpful for clinicians to conduct ultrasound-guided injections for controlling thoracic spine and chest wall pain precisely and safely.

컬러 도플러 초음파를 이용하여 발견한 견부 모기질세포종: 증례보고 (Pilomatricoma of the Shoulder Easily Identified by Color Doppler Ultrasound: A Case Report and Review of Literature)

  • 서준영;김태정;김상림;남광우
    • 대한정형외과 초음파학회지
    • /
    • 제6권1호
    • /
    • pp.10-14
    • /
    • 2013
  • 모기질세포종은 모발의 기질세포로부터 발생하는 양성 피부종양이다. 이것은 주로 두 경부 및 상지에 호발한다. 수술 전 진단의 정확성은 낮으며 단순방사선 검사만 시행한 후 절제생검을 하기도 한다. 저자들은 컬러도플러 초음파를 이용해서 쉽게 진단할 수 있었던 견부에 발생한 모기질세포종에 대해 보고하고자 한다. 초음파를 이용한 진단은 비용효과적인 측면 뿐만 아니라 종양의 내부에 대해 자세한 정보를 알 수 있다는 점에서 전산화 단층촬영이나 자기공명영상보다 더 손쉽고 유용한 진단방법으로 생각된다.

  • PDF

초음파진단기의 빔포밍 기술 (Beamforming Technology in Medical Ultrasound System)

  • 배무호
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.551-563
    • /
    • 2012
  • 초음파진단기는 1950년대부터 사용되기 시작했고 그 동안 꾸준한 기술 발전을 통해 현재 대부분의 병원에서 필수불가결한 영상진단장비로 널리 활용되고 있다. 1970년대 초음파진단기에 어레이 프로브가 사용되기 시작한 이래로 전자적 신호처리를 통한 빔포밍 기술이 초음파진단기에 적용되었고, 꾸준히 개선되어 왔다. 빔포밍 기술은 초음파진단기의 해상도를 결정짓는 중요한 신호처리 기술이다. 이 논문에서는 이 빔포밍 기술의 원리부터 최근 동향까지 간략히 소개하고자 한다. 여기에는 어레이 프로브(array probe)를 사용하는 빔포밍의 원리, 기본적 이론, 실제 구현 등이 포함되고, 또 최근 기술 중 합성구경영상(synthetic aperture imaging: SAI), 적응형 빔포밍(adaptive beamforming), 2차원 어레이 프로브를 사용하는 2차원 빔포밍 기술 등의 주제도 소개한다. 이런 다양한 빔포밍 기술들은 다양한 다른 분야의 기술들과 여러 가지 형태로 발전적으로 융합하면서 시스템의 성능을 지속적으로 향상시켜 갈 것이다.

진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기: 이론적 고찰 (Magnitudes of the Harmonic Components Emitted from Utrasonic Contrast Agents in Response to a Diagnostic Utrasound: Theoretical Consideration)

  • 강관석;유지철;팽동국;임성민;최민주
    • 한국음향학회지
    • /
    • 제24권2호
    • /
    • pp.78-86
    • /
    • 2005
  • 진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기를 이론적으로 고찰하였다. 본 연구에서는 2 MHz 진단용 초음파 펄스에 의한 초음파 조영제의 비선형 동적 반응을 Gilmore Model을 이용하여 수치 해석하였다. 초음파 조영제의 탄성 효과는 무시하였다. 초음파 조영제 반경의 크기 (1-9 $\mu$m)와 초음파의 MI 값 (0.125-8)을 변화시키면서 발생된 서브, 울트라. 2차 하모닉 성분의 파워를 기본 주파수 성분과 비교하였다. 시뮬레이션 결과, 초음파 조영제가 공진 반경 (2 $\mu$m) 보다 클 경우, 초음파 조영제에서 방출하는 서브 하모닉의 파워가 기본 주파수 것 보다 압도적으로 크게 나타났다. 특히 하모닉 영상에서 사용하는 2차 하모닉의 파워는 서브 및 울트라 하모닉 성분 보다 낮은 값을 가지는 것으로 예측되었다. 본 연구 결과는 초음파 조영제를 이용하여 하모닉 영상을 구현할 경우, 서브 및 울트라 하모닉 성분이 2차 하모닉 성분 보다 우수한 영상 변수가 될 수 있음을 시사한다.

희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현 (Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array)

  • 김강식;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.419-430
    • /
    • 2002
  • 본 논문에서는 양방향 화소단위 집속 기법을 희박 어레이 기법을 사용하여 효율적으로 구현하는 방법에 대해 제안한다. 제안한 방법은 각 주사선을 구성할 때 합성에 이용되는 부구경 사이의 간격을 멀리함으로써 적은 수의 부구경으로 큰 크기의 합성구경을 형성하여 시스템의 복잡도를 감소시키면서 초음파 영상의 해상도와 프레임율을 향상시키게 된다. 하지만 이때 합성에 사용되는 부구경 사이의 간격 증가로 인해 그레이팅 로브 값은 상승하게 된다. 이러한 그레이팅 로브는 일반적인 합성구경 기법에서는 제거할 수 있다. 하지만 본 논문에서는 일반적인 합성구경 기법과는 달리 양방향 화소단위 집속 기법에서는 부구경 사이의 간격이 클 경우 발생하는 그레이팅 로브를 제거할 수 없음을 이론적으로 해석하였다. 또한 이러한 그레이팅 로브 값을 송신 집속점을 근거리에 위치시키고 합성에 사용되는 부구경간의 간격을 수신부구경의 크기에 비례하여 적절히 선택함으로써 의료용 초음파 영상에 적합한 -40dB 이하로 억제하는 방법과 조건을 제시하였다. 모의 생체와 실제 인체 실험 결과 제안한 방법을 통해 보다 적은 수의 부구경을 이용하여 더욱 빠른 프레임율의 양방향 화소단위 집속 기법의 구현이 가능함을 확인하였다

A Synthetic Aperture Focusing Method for Three-way Dynamic Focusing

  • Kim Jung-Jun;Chang Jin-Ho;Song Tai-Kyong
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.31-35
    • /
    • 2005
  • A novel synthetic aperture method for real-time three-way dynamic focusing is proposed, which provides lateral beam patterns represented as the product of Fourier transforms of transmit subaperture, receive subaperture, and a synthetic window function. In the proposed method, all array elements are fired individually and for each firing echo signals are recorded from all elements of a receive subaperture moving along an array with the transmit element. The three-way dynamic focusing is then achieved by employing a synthetic aperture algorithm for two-way dynamic focusing and a synthetic focusing method for transmit dynamic focusing. Both theoretical analysis and computer simulation results show that the proposed method produces ultrasound beams with improved lateral resolution at all depths compared to the conventional phased array imaging and synthetic aperture focusing methods.

회전근개 파열의 수술적 치료 후 회전근개 초음파 소견 (Postoperative Ultrasound Findings of the Rotator Cuff Tendon after Arthroscopic Repair of a Rotator Cuff Tear)

  • 권동락
    • Clinical Pain
    • /
    • 제19권2호
    • /
    • pp.64-69
    • /
    • 2020
  • Ultrasound (US) imaging is an efficient, easy to use, rapid, dynamic, noninvasive, with rare side-effects and inexpensive tool allowing for facilitated diagnosis and management of the painful shoulder. It also has advantages over other imaging modalities in the evaluation of the postoperative shoulder for rotator cuff integrity and correct anchor and suture placement, as well as rotator cuff analysis following repair surgery. Early postoperative tendons frequently had a hypo- echoic echo texture and the absence of a fibrillar pattern, which might be misinterpreted as recurrent tears. however, these features often normalized into tendons with an increased echo texture and the reappearance of a fibrillar pattern at 6 months. Based on these sequential findings, the US findings within 3 months after surgery should be interpreted with caution to accurately understand and monitor the repaired tendon status.

Nipple Ultrasound: A Pictorial Essay

  • Angelica Chiorean;Roxana Maria Pintican;Madalina Szep;Diana Feier;Liliana Rogojan;Bogdan Fetica;George Dindelegan;Bura Vlad;Magdalena Duma
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.955-966
    • /
    • 2020
  • Ultrasound (US) is an attractive diagnostic approach to identify both common and uncommon nipple pathologies, such as duct ectasia, nipple abscess, nipple leiomyoma, nipple adenoma, fibroepithelial polyp, ductal carcinoma in situ (restricted to nipple), invasive carcinoma, and Paget's disease. US is the reliable first-line imaging technique to assess nipple pathologies. It is useful to identify and characterize nipple lesions. Additionally, we have presented the mammography and MRI outcomes correlated with histopathologic features for the relevant cases.

흔히 접할 수 있는 고관절 질환들과 영상 검사 (Common Hip Diseases and Their Imaging Studies)

  • 유기형
    • 대한정형외과 초음파학회지
    • /
    • 제1권1호
    • /
    • pp.40-49
    • /
    • 2008
  • 고관절은 인체에서 가장 깊이 위치라는 관절인데다가 고관절에 생긴 병변에 의한 증상은 대부분 모호하고 혼란스럽다. 이러한 이유로 고관절의 영상검사에 대한 연구와 개발은 매우 활발하게 진행되었다. 그 결과 현재는 단순 방사선 사진으로부터 복잡한 자기공명관절조영술에 이르기까지 다양한 방법이 사용되고 있다. 이 간단한 글에서 저자는 각 영상 검사법의 장단점과 흔한 고관절 질환의 영상 진단에 대해 다루고자 한다. 이러한 고관절의 영상 검사법의 중요성은 그것이 임상적인 연관이 있을 때뿐이다. 만일 우리가 각 검사법과 해당 질환들의 특성을 잘 알고 있다면 환자에 대한 가장 이상적인 접근이 가능할 것이지만 그렇지 못하다면 비싼 영상 검사는 의미 없는 그림에 지나지 않을 것이기 때문이다.

  • PDF

Ultrasonographic findings of mesenchymal chondrosarcoma of the mandible: report of a case

  • Shahidi, Shoaleh;Shakibafard, Alireza;Zamiri, Barbod;Mokhtare, Mohammad Reza;Houshyar, Maneli;Houshyar, Maral;Amanpour, Sara
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.115-119
    • /
    • 2012
  • Today, ultrasound imaging is being widely used to assess soft tissue lesions in the maxillofacial region. However, ultrasound investigations of intra-osseous lesions are rare, especially for tumors of the jaws. This report emphasized the capability of this useful imaging modality in identification of the characteristics of malignant conditions involving the bone. Mesenchymal chondrosarcoama, one of the unusual malignant conditions of the jaw, was presented in a young male with significant facial swelling. Different imaging modalities parallel with the histopathologic investigation confirmed the diagnosis. Interestingly, destruction of the bony cortex and new bone formation with a characteristic "sun ray appearance", highly suggestive of sarcomas, was manifested on the ultrasonograph. Thus, this report presented the ultrasonographic features of chondrosarcoma of mandible and considered the ultrasonography to be a useful imaging modality to evaluate intra-osseous jaw lesions.