• 제목/요약/키워드: Ultrasound Image

검색결과 427건 처리시간 0.028초

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

Edge Preserving Speckle Reduction of Ultrasound Image with Morphological Adaptive Median Filtering

  • Ryu, Kwang-Ryol;Jung, Eun-Suk
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.535-538
    • /
    • 2009
  • Speckle noise reduction for ultrasound CT image using morphological adaptive median filtering based on edge preservation is presented in this paper. Speckle noise is multiplicative feature and causes ultrasound image to degrade widely from transducer. An input image is classified into edge region and homogeneous region in preprocessing. The speckle is reduced by morphological operation on the 2D gray scale by using convolution and correlation, and edges are preserved. The adaptive median is processed to reduce an impulse noise to preserve edges. As the result, MAM of the proposed method enhances the image to about 10% in comparison with Winner filter by Edge Preservation Index and PSNR, and 10% to only adaptive median filtering.

모바일 초음파 영상신호의 빔포밍 알고리즘을 위한 멀티코어 프로세서 구현 (Implementation of Multi-Core Processor for Beamforming Algorithm of Mobile Ultrasound Image Signals)

  • 최병국;김종면
    • 정보처리학회논문지A
    • /
    • 제18A권2호
    • /
    • pp.45-52
    • /
    • 2011
  • 과거에는 환자가 초음파 영상진단장치가 설치되어 있는 방에 가서 진단을 받았지만, 현재는 의사가 초음파 영상 진단장치를 가지고 이동하면서 환자를 진단(모바일 초음파, handheld ultrasound)할 수 있는 시대가 왔다. 그러나 초음파 영상진단장치로서의 기본적인 기능만을 구현하였으며, 초음파 영상의 질을 결정하는 초음파 빔의 포커싱 알고리즘에서 요구되는 고성능을 만족하지 못하는 실정이다. 또한 모바일 기기의 경우 저전력의 요구조건도 만족하여야 한다. 이를 위해 본 논문에서는 모바일 초음파 영상신호의 포커싱을 위한 방법 중 대표적인 빔포밍 알고리즘(Beamforming Algorithm)을 고성능, 저전력으로 처리 가능한 단일 명령어 다중 데이터(Single Instruction Multiple Data, SIMD)기반의 멀티코어 프로세서를 제안한다. 제안한 SIMD기반 멀티코어 프로세서는 16개의 프로세싱 엘리먼트(Processing Element, PE)로 구성되어 있으며, 초음파의 에코 영상데이터에 내재한 무수한 데이터 레벨 병렬성을 활용하여 빔포밍 알고리즘에서 요구되는 고성능을 만족시킨다. 모의실험 결과, 제안한 멀티코어 프로세서는 현재 상용 고성능 프로세서인 TI DSP C6416보다 평균 15.8배의 성능, 6.9배의 에너지 효율 및 10배의 시스템 면적 효율을 보였다.

조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 - (A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province)

  • 양정화;이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.63-69
    • /
    • 2006
  • 초음파 영상의 질은 진단에 많은 영향을 끼친다. 양질의 영상이 항상 일정하게 유지되기 위해서는 QA(Quality Assurance) 프로그램을 가지고 주기적인 관리가 이루어져야 할 것이다. 본 논문은 임상에서의 QA 상황을 파악하는 첫 번째 단계로 실제 병원의 초음파 영상의 질을 살펴보고자 하였다. 이를 위해 인간의 생체등가물질로 된 팬텀을 이용하여 정상 환자를 스캔할 때와 같은 기준 값에서 가상의 낭포 및 고반사 신호의 구조물들이 몇 개가 보이는지 convex probe와 linear probe를 측정하여 비교하였다. convex probe에서는 정상 간과 비슷한 0.5 dB에서 vertical group, cystic masses, high contrast masses에서는 대부분 잘 보였으며 지방간과 비슷한 조건인 0.7 dB에서는 vertical group이 중간레벨에서, cystic masses와 high contrast masses에서는 대체로 모두 잘 보였다. linear probe에서의 vertical group은 0.5 dB에서 중간레벨만 잘 보였고 cystic masses와 high contrast masses는 두 개에서 네 개 보이는 것들이 고루 분포되었으나 하나도 보이는 않는 경우가 11건수나 되었다. 0.7 dB에서는 vertical group이 6개 이하가 보이는 것이 대부분 이었고 cystic masses와 high contrast masses에서도 두개에서 네 개 보이는 것들이 고루 분포되었고 하나도 보이는 않는 경우도 40건 있었다. 이로서 지방간과 같은 조건하에서는 linear probe의 영상의 질이 대체로 좋지 않으므로 기준 설정 및 물리적인 조건들을 검사 시에 잘 조정하거나 probe의 교체가 필요하다고 판단된다. 많은 병원에서 초음파 장비를 잘 관리하고 있다고 하지만, 영상의 질은 아직도 미흡한 것을 알 수 있다. 초음파 장비의 설치에서부터 영상의 질을 평가하고 지속적이고 정기적인 관리와 평가가 이루어질 수 있는 프로그램이 필요하겠다.

  • PDF

탄성 영상법 개발을 위한 유연성 높은 초음파 시스템의 구현 (Development of Flexible Ultrasound System for Elastography)

  • 김동인;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권1호
    • /
    • pp.32-38
    • /
    • 2012
  • Recently, several ultrasound imaging techniques for tissue characterization have been developed. Among them, ultrasound elastography is regarded as the most promising modality and has been rapidly developed. One of ultrasound elastography techniques is shear modulus imaging. Normal and cancerous tissues show big difference of shear moduli and they have good image contrast. However shear wave elastography requires more complicated hardware and more computations for image reconstruction algorithm. Therefore new efficient techniques are being developed. In this paper, we have developed a very flexible ultrasound system for elastography experiments. The developed system has capabilities to acquire ultrasound RF data of all channels and generate arbitrary ultrasound pulse sequences. It has a huge amount of memories for RF data acquisition and a simple and flexible pulse generator. We have verified the performance of the system showing conventional B-mode images and preliminary results of elastography. The developed system will be used to verify our own reconstruction algorithm and to develop more efficient elastography techniques.

연령에 따른 정상 골격근의 초음파 영상 분석 (Age Related Analysis of Ultrasound Images of Normal Skeletal Muscle)

  • 정진규;김계엽;김종만;김태열
    • 한국전문물리치료학회지
    • /
    • 제13권1호
    • /
    • pp.47-53
    • /
    • 2006
  • Since ultrasound has different reflections depending on components of organization, analysis of ultrasound images of skeletal muscle can offer both quantitative and qualitative reports as concerns skeletal muscle structure. This study is focused on the ultrasound method for evaluating the structural characteristics of skeletal muscle and also conducted to examine its practicality. After obtaining images of the elbow flexors from an ultrasound image device with 88 normal subjects whose ages were between twenty and seventy years old (44 men and 44 women), muscular density and white area index (WAI) which indicated structural characteristics of skeletal muscle were analyzed with gray scale analysis. The study examined correlations between subject's age and items which obtained from measuring ultrasound images and the differences in relations to sex and age. Muscular density and WAI had a high correlation with age and were significantly increased in men and women with greater age. The quantitative evaluation method of skeletal muscle structure which analyzed the ultrasound images has high practicality because it is a non-invasive method which complements physical therapy diagnosis and research methods and promotes functionality evaluation.

  • PDF

의료용 초음파 영상 시스템에서 채널신호의 스펙트럼에서 거리 가중치를 이용한 부엽의 억제 (Suppression of side lobe using distance weight in spectrum of channel signal in medical ultrasound imaging system)

  • 이유림;정목근
    • 한국음향학회지
    • /
    • 제42권3호
    • /
    • pp.203-213
    • /
    • 2023
  • 의료용 초음파 영상 시스템에서, 영상점의 밖에서 오는 신호가 초음파 수신 집속 과정에서 완전히 제거되지 않으면 부엽을 발생시킨다. 부엽의 시간 신호가 영상점에서 오는 시간 신호(주엽)와 같이 중첩되어 나타나면 시간 영역에서 필터 처리를 이용하여 완전히 제거하기 어렵다. 그러나 수신 집속 과정에서 시간 -채널 신호를 푸리에 변환하면, 주엽과 부엽의 신호는 주파수 스펙트럼 영역에서 공간적으로 분리가 된다. 따라서 스펙트럼 영역에서 계산한 주엽과 부엽의 신호크기를 이용하여 크기 가중치를 계산하여 영상에 곱함으로써 부엽을 억제하였다. 그리고 주엽과 부엽의 스펙트럼이 인접할 때, 주엽과 부엽 스펙트럼 사이의 거리에 따라 거리 가중치를 적용하였다. 64 채널 선형 트랜스듀서를 사용하는 5 MHz의 초음파 영상 시스템에서 점확산 영상과 다른 밝기의 낭종을 가지는 스페클 영상을 합성하고 가중치를 적용하여 초음파 영상을 계산하였다. 점반사체 영상에서 해상도의 변화 없이 부엽이 크게 줄어들었으며 낭종 영상에서 대조도가 크게 개선됨을 컴퓨터 시뮬레이션으로 확인하였다.

초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석 (Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images)

  • 천혜리;장현철
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.927-934
    • /
    • 2022
  • 본 연구는 간 초음파 영상을 활용하여 정량적인 측정 분석을 통해 조직 내 감쇠 지수, 조직 내 산란 분포지수 값 분석과 함께 초음파 영상 소견 간 일치도를 알아보고자 하였다. 2022년 8월부터 2022년 10월까지 지방간이 의심되어 간 초음파 검사 처방을 받은 45명의 환자를 대상으로 간 초음파 검사를 시행하였다. 연구결과, 초음파 영상 소견과 조직 내 감쇠 지수 간 일치도 분석 결과 Kappa 값이 0.82(p<0.05)로 두 검사 방법 간 매우 높은 일치도를 보였다. 또한, 초음파 영상 소견과 조직 내 산란 분포 지수 간 일치도 분석 결과에서도 Kappa 값이 0.642(p<0.05)로 두 검사 방법 간 높은 일치도를 보였다. 지방간 예측 시 간 초음파 소견 및 정량적인 초음파 검사 기법인 조직 내 감쇠 지수, 조직 내 산란 분포 지수를 활용한다면 지방간 환자의 진행 정도를 판단할 때 도움이 될 수 있을 것으로 생각된다.

라플라시안 피라미드 기반 총변동 잡음제거 기법을 이용한 초음파 영상 스펙클 제거 유용성 평가 (Evaluation on the Usefulness of Ultrasound Image Speckle Reduction Using Total Variation Denoising (TVD) Method in Laplacian Pyramid)

  • 문주혜;최동혁;이수열;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권4호
    • /
    • pp.140-146
    • /
    • 2016
  • The ultrasound imaging in medical diagnosis has become a popular modality because of its safe, noninvasive, portable, relatively inexpensive, and provides a real-time image formation. However, usefulness of ultrasound imaging is at times limited due to the presence of signal-dependent noise like as speckle. Therefore, noise reduction is very important, as various types of noise generated limits the effectiveness of medical image diagnosis. This paper introduces a speckle noise reduce algorithm using total variation denoising (TVD) in Laplacian pyramid. With this method, speckle is removed by TVD of bandpass ultrasound images in Laplacian pyramid domain. For TVD in each pyramid layer, a ${\lambda}$ is selected by trial-and-error method. The visual comparison of despeckled 'in vivo' ultrasound images from pancreas shows that the proposed method could effectively preserve edges and detailed structures while thoroughly suppressing speckle. For a Simulated B-mode image, contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were obtained like 4.65 dB and 14.11 dB, respectively. The results show that the proposed method can conduct better than some of the existing methods in terms of the CNR and the SNR.

모바일 초음파 영상신호의 빔포밍 기법을 위한 최적의 매니코어 프로세서 구현 (Implementation of an Optimal Many-core Processor for Beamforming Algorithm of Mobile Ultrasound Image Signals)

  • 최병국;김종면
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권8호
    • /
    • pp.119-128
    • /
    • 2011
  • 본 논문에서는 모바일 초음파(mobile ultrasound) 영상신호의 빔포밍 알고리즘에서 요구되는 고성능 및 저전력을 만족시키는 매니코어 프로세서에 대한 디자인 공간 탐색 방법을 소개한다. 매니코어 프로세서의 디자인 공간 탐색을 위해 매니코어의 각 프로세싱 엘리먼트(Processing Element, PE)당 초음파 영상신호 데이터의 수를 변화시키는 실험을 통해 실행시간, 에너지 효율 및 시스템 면적 효율을 측정하고, 측정된 결과를 바탕으로 최적의 매니코어 프로세서 구조를 선택하였다. 모의실험 결과, PE 개수가 4096일 때 에너지 효율이 가장 높았으며, PE 개수가 1024일 때 가장 높은 시스템 면적 효율을 보였다. 또한, PE 개수가 4096인 매니코어 아키텍처는 초음파 영상장치에 가장 많이 사용되는 TI DSP C6416보다 각각 에너지 효율에서 46배, 시스템 면적 효율에서 10배의 향상을 보였다.