• Title/Summary/Keyword: Ultrasound Energy

Search Result 189, Processing Time 0.03 seconds

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Fabrication of Nanocomposite Powders by Sonochemical Method

  • Hayashi, Yamato;Sekino, Tohru;Niihara, Koichi
    • Journal of Powder Materials
    • /
    • v.8 no.3
    • /
    • pp.207-209
    • /
    • 2001
  • Nano particles have recently been a major research interest, motivated by their unusual physical and chemical properties. Such particles can be synthesized using physical and chemical methods. The physical methods need expensive installation like vacuum induction furnace, whereas in chemical methods the process in generally very simple and low cost. In this study, simple and new fabrication process by using ultrasound was investigated to prepare the nano-sized metal particles on various powders at room temperature.

  • PDF

A Study of Electronic Generation Technique for Dual Ultrasonic Transmitters for the Scale Prevention (스케일 방지를 위한 2쌍 초음파 발신기 구동기법 연구)

  • Heo, Pil-U;Lee, Yang-Rae;Im, Ui-Su
    • 연구논문집
    • /
    • s.28
    • /
    • pp.137-143
    • /
    • 1998
  • In the case of a boiler, scale is made in the tube by the chemical reactions of Ca and Mg ions contained in the water, and heat transfer rate is reduced because of increasement of heat resistance in the pipe of the heat flow. Thus it brings to reduce the energy efficiency and to make environmental pollution by the use of chemicals for the prevention and removement of scale. In this paper, we discussed the design of electronic generator for dual ultrasonic transmitters and analyzed the effect of scale prevention by ultrasound.

  • PDF

Retrospective Analysis of Cytopathology using Gray Level Co-occurrence Matrix Algorithm for Thyroid Malignant Nodules in the Ultrasound Imaging (갑상샘 악성결절의 초음파영상에서 GLCM 알고리즘을 이용한 세포병리 진단의 후향적 분석)

  • Kim, Yeong-Ju;Lee, Jin-Soo;Kang, Se-Sik;Kim, Changsoo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.237-243
    • /
    • 2017
  • This study evaluated the applicability of computer-aided diagnosis by retrospective analysis of GLCM algorithm based on cytopathological diagnosis of normal and malignant nodules in thyroid ultrasound images. In the experiment, the recognition rate and ROC curve of thyroid malignant nodule were analyzed using 6 parameters of GLCM algorithm. Experimental results showed 97% energy, 93% contrast, 92% correlation, 92% homogeneity, 100% entropy and 100% variance. Statistical analysis showed that the area under the curve of each parameter was more than 0.947 (p = 0.001) in the ROC curve, which was significant in the recognition of thyroid malignant nodules. In the GLCM, the cut-off value of each parameter can be used to predict the disease through analysis of quantitative computer-aided diagnosis.

Association of Calcium Intake and Bone Mineral Density by Vitamin D Receptor Genotype among Elderly Women Living in Rural a Area (노년기 농촌여성의 비타민 D 수용체 유전자형에 따른 칼슘 섭취량과 골밀도와의 관계)

  • Kim Ji-Sun;Kim Hee-Seon
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.4
    • /
    • pp.534-540
    • /
    • 2006
  • Recent studies have shown that environmental, biochemical, nutritional or genetic factors affect bone mineral density (BMD). The purpose of the present study was to investigate the effect of vitamin D receptor (VDR) gentotype and nutritional status on BMD of elderly women living in a rural area. Three hundred thirty five elderly women over 65 years in Asan participated the study. Data for demographic and nutrient intakes were obtained by survey with a two day 24 hr recall method. BMD was measured by broadband ultrasound attenuation (BUA) using quantitative ultrasound (QUS). VDR genotypes of the subjects analyzed with Bsm I restriction enzyme were bb (92%), Bb (7%) and BB (1%). No differences were found between genotypes bb and Bb/BB in age, menopausal age, body mass index and body fat. BUA of bb genotype was higher (62.5 $\pm$ 15.6 dB/MHz) than Bb/BB genotype (56.1 $\pm$ 17.6 dB/MHz) by Student's t-tests. Correlation analyses showed strong negative correlation of BMD and age, but positive correlation with BMI, energy and calcium intake. When subgroup analyses were conducted after stratification by the median calcium intake level (412.9 mg/d), the above median calcium intake group showed significant difference in BUA by VDR genotype while the lower median calcium intake group did not show significant difference. The current study confirmed interaction of calcium intake and VDR genotype in association with BMD. Further nutritional intervention will be needed to improve calcium status of the elderly women living in rural areas.

An Efficient Motion Estimation and Compensation Method for Ultrasound Synthetic Aperture Imaging (초음파 합성구경 영상을 위한 효율적인 움직임 추정 및 보상 기법)

  • 김강식;황재섭;정종섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.87-99
    • /
    • 2002
  • This paper describes a method for overcoming the motion artifacts inherent in synthetic aperture(SA) imaging. based on the investigation results as to the influence of a target motion on synthetic aperture techniques. This method uses a region-based motion compensation approach in which only the axial motion is estimated and compensated for a given region of interest(ROI) under the assumption that the whole ROI moves uniformly The estimated axial motion is calculated with a crosscorrelation(CC) method at the Point where the focused signal has the maximum energy within the ROI. We also presents a method for estimating the axial motion using the autocorrelation(AC) method that is widely used to estimate average Doppler frequency Both computer simulations and in vivo experiments show that the proposed methods can improve greatly the spatial resolution and SNR of ultrasound imaging by implementing the SA techniques for two-way dynamic focusing without motion artifacts. In addition the AC-barred motion compensation method provides almost the same results as the CC-based one, but with a dramatically reduced computational complexity.

Characterization of Elastic Modulus of Kelvin Foam Using Elastic Structural Model and Ultrasound (초음파와 탄성 구조 모델을 이용한 캘빈 폼 재료의 탄성계수 평가)

  • Kim, Woochan Ethan;Kim, Nohyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.474-482
    • /
    • 2016
  • A Kelvin foam plate - widely used in the energy and transport industries as a lightweight structural material - was examined to estimate its Young's modulus using ultrasound. An isotropic tetrakaidecahedron foam structure was designed in SolidWorks and printed using 3D printer with an ABS plastic material. The 3D printed foam structure was used to build a foam plate with a 14 mm thickness ($50mm{\times}100mm$ in size) for the ultrasonic test. The Kelvin foam plate, a significantly porous medium, was completely filled with paraffin wax to enable the ultrasound to penetrate through the porous medium. The acoustic wave velocity of the wax-filled Kelvin foam was measured using the time of flight (TOF) method. Furthermore, the elastic modulus of the Kelvin foam was estimated based on an elastic structural model developed in this study. The Young's modulus of the produced Kelvin foam was observed to be approximately 3.4% of the bulk value of the constituent material (ABS plastic). This finding is consistent with experimental and theoretical results reported by previous studies.

Kinetic Study of the Visible Light-Induced Sonophotocatalytic Degradation of MB Solution in the Presence of Fe/TiO2-MWCNT Catalyst

  • Zhang, Kan;Oh, Won-Chun
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1589-1595
    • /
    • 2010
  • In order to effective degradation of organic dye both under visible light or ultrasonic irradiation, the MWCNTs (multiwalled carbon nanotube) deposited with Fe and $TiO_2$ were prepared by a modified sol-gel method. The Fe/$TiO_2$-MWCNT catalyst was characterized by surface area of BET, scanning electron microscope (SEM), Transmission Electron Microscope (TEM), X-ray diffraction (XRD), and energy dispersive X-ray (EDX) and ultraviolet-visible (UV-vis) spectroscopy. The low intensity visible light and low power ultrasound was as an irradiation source and the methylene blue (MB) was choose as the model organic dye. Then degradation experiments were carried out in present of undoped $TiO_2$, Fe/$TiO_2$ and Fe/$TiO_2$-MWCNT catalysts. Through the degradation of MB solution, the results showed the feasible and potential use of Fe/$TiO_2$-MWCNT catalyst under visible light and ultrasonic irradiation due to the enhanced formation of reactive radicals as well as the possible visible light and the increase of ultrasound-induced active surface area of the catalyst. After addition of $H_2O_2$, the MB degradation rates have been accelerated, especially with Fe/$TiO_2$-MWCNT catalyst, in case of that the photo-Fenton reaction occurred. The sonophotocatalysis was always faster than the respective individual processes due to the more formation of reactive radicals as well as the increase of the active surface area of Fe/$TiO_2$-MWCNT catalyst.

Quantitative Ultrasound for Osteoporosis Screening in Postmenopausal Women (폐경 후 여성에서 골다공증의 조기검진도구로서 골초음파의 유용성)

  • Shin, Hee-Young;Jung, Eun-Kyung;Rhee, Jung-Ae;Choi, Jin-Su;Shin, Min-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.408-416
    • /
    • 2001
  • Objectives : To evaluate the diagnostic value of quantitative ultrasound (QUS) in the prediction of osteoporosis as defined by dual energy x-ray absorptiometry (DEXA) in postmenopausal women. Methods : Questionnaires and height and weight measurements were used in the investigation of 176 postmenopausal women. QUS measurements were taken on the right calcaneus while bone mineral density (BMD) measurements of the lumbar spine and femoral neck were made with DEXA. The areas under the curves (AUC) of the speed of sound (SOS) for osteoporosis in the lumbar spine and femoral neck were obtained through receiver operating characteristic (ROC) analysis and evaluated. A comparison was made, for osteoporosis in the lumbar spine and femoral neck, between the AUCs of the logistic model with clinical risk factors and SOS. Results : Pearson's correlation coefficients of SOS and lumbar spine BMD, and of SOS and femoral neck BMD were 0.26 and 0.37. The AUC for the logistic model in its discrimination for lumbar spine osteoporosis was 0.764, and for SOS 0.605. The AUCs for the logistic model in its discrimination for femoral neck osteoporosis and for SOS were 0.890 and 0.892, respectively. Conclusions : These results suggest that the diagnostic value of QUS as a screening tool for osteoporosis is moderate for the femoral neck, but merely low for the lumbar spine and that the predictability provided by SOS is no better than that by the sole use of clinical risk factors in postmenopausal women.

  • PDF

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction