• Title/Summary/Keyword: Ultrasound Diagnosis

Search Result 539, Processing Time 0.027 seconds

Loose Body in the Interphalangeal Joint of the Big Toe (무지 지절에 발생한 관절내 유리체 - 증례보고 -)

  • Bae, Woo-Han;Moon, Jeong-Seok;Lee, Woo-Chun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.24-26
    • /
    • 2009
  • A 20-year-old patient who got injured on his right big toe and complained pain visited to our hospital 9 months ago. Before the patient transferred to our hospital, plain radiographs were obtained at a private hospital and the patient underwent conservative treatment with uncertain diagnosis. However, the symptom was not improved, and he continued to complain intra-articular pain on his interphalangeal joint of big toe during plantarflexion or dorsiflexion. On plain radiographs of our hospital, we observed small bone fragment in his interphalangeal joint of the big toe. On the ultrasonographic images, two loose bodies in the interphalangeal joint were found. Then, we removed the loose bodies as surgical treatment, and the symptom was subsided completely. The purpose of this study is to report the ultrasonographic finding of the loose bodies of interphalangeal joint of the big toe.

  • PDF

Ulnar Nerve Subluxation Diagnosed by Dynamic Ultrasonography (동적 초음파를 이용하여 진단한 주관절 척골 신경 아탈구)

  • Ji, Jong-Hun;Jung, Jae-Jung;Kim, Young-Yul;Kang, Hyun-Taek;Park, Sang-Eun;Kim, Dong-Jin
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.79-83
    • /
    • 2010
  • Musculoskeletal ultrasonography has been used as a convenient and simple tool for diagnosis of various conditions of orthopaedic diseases for many years. Generally magnetic resonance imaging (MRI) is thought to be the best method to search for anatomical structures or variations. However, for dynamic conditions such as dislocation or subluxation of tendons and nerves, MRI is not superior to ultrasonography, especially dynamic ultrasonography. So we present such a patient with an ulnar nerve subluxation at the elbow who has symtoms mimicking cubital tunnel syndrome diagnosed by dynamic ultrasonography and treated successfully by ulnar nerve anterior transposition and think that dynamic ultrasonography is a useful method for diagnosing dynamic condition such as ulnar nerve subluxation mimicking cubital tunnel syndrome.

  • PDF

New insights into pathways of the accessory nerve and transverse cervical artery for distal selective accessory nerve blockade

  • Heo, Yanguk;Cho, Namju;Cho, Hyunho;Won, Hyung-Sun;Yang, Miyoung;Kim, Yeon-Dong
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.48-53
    • /
    • 2020
  • Background: The aim of this study was to clarify the topographical relationship between the accessory nerve (AN) and transverse cervical artery (TCA) to provide safe and convenient injection points for AN blockade. Methods: This study included 21 and 30 shoulders of 14 embalmed Korean adult cadavers and 15 patients, respectively, for dissection and ultrasound (US) examination. Results: The courses of the TCA and AN in the scapular region were classified into four types based on their positional relationships. Type A indicated the nerve that was medial to the artery and ran parallel without changing its location (38%). In type B (38%), the nerve was lateral to the artery and ran parallel without changing its location. In type C (19%), the nerve or artery traversed each other only once during the whole course. In type D (5%), the nerve or artery traversed each other more than twice forming a twist. At the levels of lines I-IV, the nerve was relatively close to the artery (approximately 10 mm). TCAs were observed in all specimens around the superior angle of the scapula at the level of line II, whereas they were not found below line VI. In US images of the patients, the TCA was commonly observed at the level of line II (93.3%) where all ANs and TCAs were observed in cadaveric dissection. Conclusions: The results expand the current knowledge of the relation between the AN and TCA, and provide helpful information for selective diagnostic nerve blocks in the scapular region.

The Prevalence of Thyroid Nodules and the Morphological Analysis of Malignant Nodules on Ultrasonography (갑상선 결절 유병률과 초음파 영상에서 악성소견 결절의 형태학적 분석)

  • An, Hyun;Ji, Tae-jeong;Lee, Hyo-young;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.201-207
    • /
    • 2019
  • The purpose of this study was to evaluate the prevalence of thyroid nodules and malignant findings of thyroid nodules in 1,954 patients (654 males and 1,300 females) aged 20 years or older who underwent thyroid ultrasound from January 2018 to December 2018. Examination of the thyroid gland was performed, and fine needle aspiration cytology was performed on the thyroid nodule. As a result, 108 (16.5%) out of 654 males and 368 (28.3%) out of 1,300 females showed higher prevalence than males. The prevalence of single nodules and multiple nodules in gender and age groups was significantly higher for women and for ages (male p=.001, female p=.001). There was a significant difference in males in the nodule size (p=.001) and no significant difference in females (p=.069). Fine - needle aspiration cytology of 476 patients with nodules was diagnosed as malignant in 46 patients (9.6%). Based on pathologic results, 383 benign and 93 malignant groups were analyzed. Ultrasonographic findings were as follows single nodule (p=.000), solid(p=.004), hypoechoic (p=.000), ill-defined peripheral boundary (p=.000), and calcification (p=.000), respectively. In the diagnosis of thyroid nodule, primary ultrasonographic findings through morphological classification of the nodules may reduce indiscriminate fine needle aspiration cytology in benign and malignant nodules.

Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs

  • Su An Kim;Jaeho Shim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • Background: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. Objectives: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. Methods: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. Results: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 ㎛, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 ㎛, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 ㎛ with a 95% LoA span of 1,110.95 ㎛, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. Conclusions: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.

Multiple Aneurysms with Thrombosis on the Small Saphenous Vein (소복재정맥에서 발생한 혈전을 동반한 여러 개의 정맥류)

  • Chan Kang;Jae-Hwang Song;Yougun Won;Eric W. Tan;Gi-Soo Lee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.28 no.1
    • /
    • pp.27-30
    • /
    • 2024
  • Several types of soft tissue masses occur in the lower extremities. A mass associated with blood vessels is often difficult to diagnose. A 15-year-old male patient visited the author's hospital with discomfort and edema in his right calf that had persisted for six months. A physical examination showed no palpable mass other than mild edema. Three masses were found during the ultrasound scan along the small saphenous vein. The masses had a cyst-like appearance and were filled with thrombus. In duplex ultrasound, vascular reflux was represented inside the masses. During surgery, it was suspected that vascular deformation occurred in the small saphenous vein, and simple ligation and resection treatments were performed. The patient was finally diagnosed with venous aneurysms accompanied by thrombosis based on the histology tests. The symptoms disappeared after surgery, and there were no recurrences or unusual findings at the follow-up one year later. Venous aneurysms occurring in the superficial veins of the lower extremities are rarely reported, but treatment and diagnosis are important. This paper reports a case of an aneurysm on the small saphenous vein.

The Effectiveness of Ultrasound-guide Steroid Injection According to Morton's Neuroma Size (모톤씨 신경종 크기에 따른 초음파 유도하 스테로이드 주사 효과의 비교분석)

  • Kim, Hak Jun;Hur, Chang Ryong;Kim, Jae Kyun;Jang, Kyu Seon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.61-65
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effectiveness of ultrasound-guide steroid injection according to Morton's neuroma size. Materials and Methods: From October 2008 to September 2011, 17 patients (23 cases) diagnosed with Morton's neuroma were investigated. All cases were female and mean age was 52.6 years old. Neuroma were measured by the horizontal and longitudinal length of the mass and underwent ultrasound-guided steroid (5 mg dexamethasone) injection. The efficacy of the injection was determined by Visual Analogue Scale pain score and patient satisfaction(subdivided 4 group-much improved, improved, not improved, aggrevation) Results: 7 of 23(30.4%) cases showed much improved and improved satisfaction and mean longitudinal and horizontal length were $0.71{\pm}0.39cm$ and $0.47{\pm}0.24cm$, respectively. 16 of 23(69.6%) cases showed not improved and aggrevation satisfaction and mean longitudinal and horizontal length were $0.83{\pm}0.42cm$ and $0.54{\pm}0.14cm$, repectively. There was a significant difference in VAS and patient satisfaction in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm. (p<0.05) Conclusion: The ultrasonography is a important modality in diagnosis and treatment of morton's neuroma. Ultrasound-guide steroid injection is effective in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm, respectively.

  • PDF

Development of High Intensity Focused Ultrasound (HIFU) Mediated AuNP-liposomal Nanomedicine and Evaluation with PET Imaging

  • Ji Yoon Kim;Un Chul Shin;Ji Yong Park;Ran Ji Yoo;Soeku Bae;Tae Hyeon Choi;Kyuwan Kim;Young Chan Ann;Jin Sil Kim;Yu Jin Shin;Hokyu Lee;Yong Jin Lee;Kyo Chul Lee;Suhng Wook Kim;Yun-Sang Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • Liposomes as drug delivery system have proved useful carrier for various disease, including cancer. In addition, perfluorocarbon cored microbubbles are utilized in conjunction with high-intensity focused-ultrasound (HIFU) to enable simultaneous diagnosis and treatment. However, microbubbles generally exhibit lower drug loading efficiency, so the need for the development of a novel liposome-based drug delivery material that can efficiently load and deliver drugs to targeted areas via HIFU. This study aims to develop a liposome-based drug delivery material by introducing a substance that can burst liposomes using ultrasound energy and confirm the ability to target tumors using PET imaging. Liposomes (Lipo-DOX, Lipo-DOX-Au, Lipo-DOX-Au-RGD) were synthesized with gold nanoparticles using an avidin-biotin bond, and doxorubicin was mounted inside by pH gradient method. The size distribution was measured by DLS, and encapsulation efficiency of doxorubicin was analyzed by UV-vis spectrometer. The target specificity and cytotoxicity of liposomes were assessed in vitro by glioblastoma U87mg cells to HIFU treatment and analyzed using CCK-8 assay, and fluorescence microscopy at 6-hour intervals for up to 24 hours. For the in vivo study, U87mg model mouse were injected intravenously with 1.48 MBq of 64Cu-labeled Lipo-DOX-Au and Lipo-DOX-Au-RGD, and PET images were taken at 0, 2, 4, 8, and 24 hours. As a result, the size of liposomes was 108.3 ± 5.0 nm at Lipo-DOX-Au and 94.1 ± 12.2 nm at Lipo-DOX-Au-RGD, and it was observed that doxorubicin was mounted inside the liposome up to 52%. After 6 hours of HIFU treatment, the viability of U87mg cells treated with Lipo-DOX-Au decreased by around 20% compared to Lipo-DOX, and Lipo-DOX-Au-RGD had a higher uptake rate than Lipo-DOX. In vivo study using PET images, it was confirmed that 64Cu-Lipo-DOX-Au-RGD was taken up into the tumor immediately after injection and maintained for up to 4 hours. In this study, drugs released from liposomes-gold nanoparticles via ultrasound and RGD targeting were confirmed by non-invasive imaging. In cell-level experiments, HIFU treatment of gold nanoparticle-coupled liposomes significantly decreased tumor survival, while RGD-liposomes exhibited high tumor targeting and rapid release in vivo imaging. It is expected that the combination of these models with ultrasound is served as an effective drug delivery material with therapeutic outcomes.

A Follow-up Study of DMSA Renal Scan in Children with . Acute Pyelonephritis and Vesicoureteral Reflux (급성신우신염과 방광요관역류 환아에서 DMSA신주사의 추적관찰)

  • Oh, Chang-Hee;Choi, Won-Kyoo;Kim, Ji-Hong;Lee, Jae-Seung;Kim, Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.145-151
    • /
    • 1998
  • Purpose : DMSA renal scan is known as a valuable method for evaluating acute pyelonephritis and renal scar in patients with febrile urinary tract infection or vesicoureteral reflux. We made this study, to determine the most effective use of DMSA renal scan. Methods : 155 children were admitted to the Pediatric Department of Yonsei University, Severance hospital with the symptom of urinary tract infection from January, 1992 to June, 1995. DMSA scan, renal ultrasound and VCUG were performed. One consisted of 29 patients with the diagnosis of acute pyelonephritis without vesicoureteral reflux and the otherconsistedofllpatientswithvesicoureteralreflux. Results : The follow-up DMSA scans at mean $0.99{\pm}0.46$ months after the initial DMSA scans were performed in the 29 children with acute pyetonephritis. 21($72.4\%$) of 29 children showed normal DMSA scans. 8 children with abnormal DMSA scans had follow-up DMSA scans at 2.5 months after the initial scans and 6 of 8 children showed normal DMSA scans. Only 12($41.4\%$) of 29 children showed abnormal renal ultrasound. The data about DMSA scans in 32 children with vesicoureteral reflux showed that there were abnormal DMSA scans in Grade $I;25.0\%$, Grade $II;44.5\%$, Grade $III;64.3\%$, Grade $IV;92.9\%$ and Grade $V;100.0\%$. There was a significant difference in that 36 renal unit ($68.0\%$) on DMSA renal scan and 26 renal units ($49.1\%$) on renal ultrasound showed abnormal finding(P<0.05). Conclusion : DMSA renal scan is more useful than renal ultrasound for the diagnosis of acute pyelonephritis. It is considered that if the initial DMSA scan is abnormal, a follow-up DMSA scan must be performed after 10weeks (8-12weeks) and the change in DMSA scan evaluated.

  • PDF