• Title/Summary/Keyword: Ultrasound (US)

Search Result 244, Processing Time 0.021 seconds

Useful Ultrasound Findings of Pediatric Patients with Equivocal Results of Appendicitis: Analysis Based on a Structured Report Form (애매한 초음파 결과를 보인 소아 환자에서 충수돌기염을 감별하는데 유용한 초음파 소견: 구조화 판독문에 기초한 분석)

  • Jiyoung Choi;Hyuk Jung Kim;Suk Ki Jang;Hyun Jin Kim;Jae Woo Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.182-193
    • /
    • 2021
  • Purpose To identify the features that can be used for differentiating appendicitis from non-appendicitis in pediatric patients with equivocal ultrasound (US) results. Materials and Methods A total of 53 pediatric patients (≤ 18 years old) with equivocal results on US examination for suspected appendicitis between November 2012 and October 2017 were included. US evaluation was conducted based on information retrieved from a predefined structured report form. Then, the likelihood of appendicitis was prospectively classified into five categories. The equivocal results were considered as grade 3 (indeterminate) and grade 4 (probably appendicitis). Results Of the 53 patients, 25 (47.2%) and 28 (52.8%) were classified into grade 3 and 4 groups, respectively. Among the individual US findings, increased vascularity of the appendiceal wall and peri-appendiceal fat infiltration were independent findings associated with the diagnosis of appendicitis (p = 0.005, p = 0.045, respectively) in the multivariate logistic regression analysis and showed the highest diagnostic accuracy (69.8% and 62.3%, respectively). Conclusion Increased vascularity within the appendiceal wall and peri-appendiceal fat infiltration were significant predictors of appendicitis in patients with equivocal US findings.

Effect of a Deep Learning Framework-Based Computer-Aided Diagnosis System on the Diagnostic Performance of Radiologists in Differentiating between Malignant and Benign Masses on Breast Ultrasonography

  • Ji Soo Choi;Boo-Kyung Han;Eun Sook Ko;Jung Min Bae;Eun Young Ko;So Hee Song;Mi-ri Kwon;Jung Hee Shin;Soo Yeon Hahn
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.749-758
    • /
    • 2019
  • Objective: To investigate whether a computer-aided diagnosis (CAD) system based on a deep learning framework (deep learning-based CAD) improves the diagnostic performance of radiologists in differentiating between malignant and benign masses on breast ultrasound (US). Materials and Methods: B-mode US images were prospectively obtained for 253 breast masses (173 benign, 80 malignant) in 226 consecutive patients. Breast mass US findings were retrospectively analyzed by deep learning-based CAD and four radiologists. In predicting malignancy, the CAD results were dichotomized (possibly benign vs. possibly malignant). The radiologists independently assessed Breast Imaging Reporting and Data System final assessments for two datasets (US images alone or with CAD). For each dataset, the radiologists' final assessments were classified as positive (category 4a or higher) and negative (category 3 or lower). The diagnostic performances of the radiologists for the two datasets (US alone vs. US with CAD) were compared Results: When the CAD results were added to the US images, the radiologists showed significant improvement in specificity (range of all radiologists for US alone vs. US with CAD: 72.8-92.5% vs. 82.1-93.1%; p < 0.001), accuracy (77.9-88.9% vs. 86.2-90.9%; p = 0.038), and positive predictive value (PPV) (60.2-83.3% vs. 70.4-85.2%; p = 0.001). However, there were no significant changes in sensitivity (81.3-88.8% vs. 86.3-95.0%; p = 0.120) and negative predictive value (91.4-93.5% vs. 92.9-97.3%; p = 0.259). Conclusion: Deep learning-based CAD could improve radiologists' diagnostic performance by increasing their specificity, accuracy, and PPV in differentiating between malignant and benign masses on breast US.

The Change of Pressure Pain Threshold of Myofascial Trigger Points by Ultrasound Application Method (초음파 적용방식에 따른 근-근막 발통점의 압통각 역치 변화)

  • Lee, Jeong-Woo;Yoon, Se-Won
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.2
    • /
    • pp.61-68
    • /
    • 2003
  • The purpose of this study was to compare the application method of ultrasound on the alteration of pressure pain threshold of myofascial trigger points. We used thirty patients with mayofascial pain syndrome in upper trapezius. Participants classified according to each group in non noxious dose, noxious dose by the ultrasound. The test was measured continuously pre test, post-test by algometer. The following results were obtained; 1. Pressure pain threshold were significantly increased in non-noxious dose and noxious dose group(p<.001). 2. In noxious dose group, pressure pain threshold were more significantly increased than non-noxious dose group(p<.001). These results lead us to the conclusion that non-noxious dose and noxious dose were significantly increased pressure pain threshold of upper trapezius trigger points. Therefore, a further direction of this study will be to provide more evidence that noxious dose have more effect on pressure pain threshold of myofascial trigger points.

  • PDF

Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities (3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Choe, Bo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

Daily localization of partial breast irradiation patients with three-dimensional ultrasound imaging

  • Sayan, Mutlay;Vergalasova, Irina;Hard, Daphne;Wrigth, Heather;Archambault, Jessica;Gagne, Havaleh;Nelson, Carl;Heimann, Ruth
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.259-264
    • /
    • 2019
  • Purpose: Accurate localization of the lumpectomy cavity during accelerated partial breast radiation (APBR) is essential for daily setup to ensure the prescribed dose encompasses the target and avoids unnecessary irradiation to surrounding normal tissues. Three-dimensional ultrasound (3D-US) allows direct visualization of the lumpectomy cavity without additional radiation exposure. The purpose of this study was to evaluate the feasibility of 3D-US in daily target localization for APBR. Materials and methods: Forty-seven patients with stage I breast cancer who underwent breast conserving surgery were treated with a 2-week course of APBR. Patients with visible lumpectomy cavities on high quality 3D-US images were included in this analysis. Prior to each treatment, X-ray and 3D-US images were acquired and compared to images from simulation to confirm accurate position and determine shifts. Volume change of the lumpectomy cavity was determined daily with 3D-US. Results: A total of 118 images of each modality from 12 eligible patients were analyzed. The average change in cavity volume was 7.8% (range, -24.1% to 14.4%) on 3D-US from simulation to the end-of-treatment. Based on 3D-US, significantly larger shifts were necessary compared to portal films in all three dimensions: anterior/posterior (p = 7E-11), left/right (p = 0.002), and superior/inferior (p = 0.004). Conclusion: Given that the lumpectomy cavity is not directly visible via X-ray images, accurate positioning may not be fully achieved by X-ray images. Therefore, when the lumpectomy cavity is visible on US, 3D-US can be considered as an alternative to X-ray imaging during daily positioning for selected patients treated with APBR, thus avoiding additional exposure to ionizing radiation.

The Clinical Usefulness of Ultrasound-Guided Fine Needle Aspiration Cytology in Thyroid Nodules (갑상선 결절에서 초음파 유도 미세침흡인검사의 임상적 유용성)

  • Kim, Mi-Young;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • Thyroid nodules are a common disease in clinical practice. Fine needle aspiration (FNA) is an accurate and safe method for the diagnosis of thyroid nodules. One of the limitations of FNA is the variable rate of unsatisfactory specimens, especially in small sized, deep seated or complex cystic nodules. To overcome this problem, ultrasound-guided FNA (US-FNA) has been widely used. In this study, the clinical usefulness of US-FNA cytology in thyroid nodules was investigated. Female to male ratio was 6.58:1. The incidence of nodules were 157 (43.1%) cases on the right, 130 (35.7%) cases on the left and 9 (2.5%) cases in isthmus. Total 139 cases (38.2%) belong to less than 1cm and 225 cases (61.8%) belong to more than 1cm. As for the echo type in the nodules, solid types were 255(70.1%), cystic type 39 (10.7%) cases, and the percentage of mixed type was 19.2%. The results show that US-FNA reduces the possibility of unsatisfactory cytologic specimens and the rate of false-negative diagnosis, and improves the diagnostic accuracy in investigation thyroid nodules.

  • PDF

Application of Computer-Aided Diagnosis a using Texture Feature Analysis Algorithm in Breast US images (유방 초음파영상에서 질감특성분석 알고리즘을 이용한 컴퓨터보조진단의 적용)

  • Lee, Jin-Soo;Kim, Changsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.507-515
    • /
    • 2015
  • This paper suggests 6 cases of TFA parameters algorithm(Mean, VA, RS, SKEW, UN, EN) to search for the detection of recognition rates regarding breast disease using CAD on ultrasound images. Of the patients who visited a university hospital in Busan city from August 2013 to January 2014, 90 cases of breast ultrasound images based on the findings in breast US and pathology were selected. $50{\times}50$ pixel size ROI was selected from the breast US images. After pre-processing histogram equalization of the acquired test images(negative, benign, malignancy), we calculated results of TFA algorithm using MATLAB. As a result, in the TFA parameters suggested, the disease recognition rates for negative and malignancy was as high as 100%, and negative and benign was approximately 83~96% for the Mean, SKEW, UN, and EN. Therefore, there is the possibility of auto diagnosis as a pre-processing step for a screening test on breast disease. A additional study of the suggested algorithm and the responsibility and reproducibility for various clinical cases will determine the practical CAD and it might be possible to apply this technique to range of ultrasound images.

Visualization of Temperature Elevation Due to Focused Ultrasound in Dissipative Acoustic Medium (음향감쇠매질 내에서 집속초음파에 의한 온도상승의 가시화)

  • Kim, Myoungseok;Kim, Jungsoon;Kim, Moojoon;Ha, Kanglyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.21-30
    • /
    • 2014
  • The temperature change due to focused ultrasound in dissipative acoustic medium is very important because it provides us much information. To measure the temperature change inside of the dissipative acoustic medium non-invasively, we adopt a temperature sensitive film which has thermochromic particles with critical temperature of $30^{\circ}C$. As a dissipative acoustic medium, agar layer is chosen in the study. The temperature change due to the ultrasound was measured depending on the concentration of the sugar in the agar layer. The color change on the film due to the ultrasound was investigated when the concentration of sugar was from 25% to 40%. As the result, there were rapid increases of discolored area on the film within 2~5 second after the ultrasound driving and the increasing rates decreased after the period. To compare the simulation results were also shown. However in the simulated result, the discolored areas linearly increased from start to 10 seconds. The reason of the differences between the experimental results and simulated ones is that the change of thermal conductivity and heat capacity of the medium were not considered in the simulation program.

Disease Testing in Pelvic Pain Patients: Comparison between Ultrasound and Computed Tomography Imaging (골반통 환자의 질환 검사: 초음파와 컴퓨터단층촬영 간의 비교)

  • EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.385-390
    • /
    • 2023
  • The uterus, one of women's reproductive organs, is also closely related to women's health. Among them, hemorrhagic luteal cysts, one of the causes of pelvic pain that women often experience, were observed through CT and ultrasound, and the quality of images was evaluated through quantitative and qualitative evaluations. This study sought to find out whether the test method is more helpful to patients during CT and ultrasound. This study was conducted on 15 adolescent women and 15 adult women(21.31±3.45 average age). The equipment used for filming used EC3-10X (3~10 MHZ) and Philips Mx8000 iCT 256 among Endocavity Probes among Ecube Platinum. After setting a constant ROI on the cyst and the interface as a quantitative analysis method, SNR and CNR values were measured on a 5-point scale based on image quality, lesion clarity, image distortion, clarity of the interface, and motion artifacts (p<0.05). Independent t-test and Mann Whiteny U were performed, and the statistical program used was noted when SPSS (Version 22.0 for windows software package, Chicago, IL, USA) was statistically less than 0.05. Comparing the SNR and CNR values for this experiment, it can be seen that the SNR value was higher in the case of CT images(p<0.05). As a result of the qualitative evaluation, the quality of the image, the clarity of the lesion, the distortion of the image, the clarity of the interface, and the clarity of the boundary were measured on a 5-point scale based on the movement artifact. Comparing each score, CT images scored higher with a finer difference than ultrasound images(p<0.05). In conclusion, both test methods showed excellent results in finding the patient's lesions. However, in quantitative and qualitative evaluations, CT produced higher results in detecting lesions than ultrasound. However, for cyst tests that require continuous observation, ultrasonography, a non-invasive method that is advantageous for patients, will be clinically useful. Therefore, observing the patient's lesions by appropriately distributing these two test methods will provide optimal diagnostic information. These results will be useful for providing clinical basic data and educational materials to CT and US users in the future.