• Title/Summary/Keyword: Ultrasonographic evaluation

Search Result 98, Processing Time 0.026 seconds

The Effect of Muscle Activity on Muscle Architectural of Medial Gastrocnemius in Chronic Stroke Patient Based on Ankle Joint Degree (만성 뇌졸중 환자에서 발목관절 각도에 따른 근 수축이 내측 비복근의 근 구조에 미치는 영향)

  • Kim, Tae-Gon;Bae, Sea-Hyun;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3991-3998
    • /
    • 2012
  • The aim of this study was to effect of muscle activity on muscle architectural of medial gastrocnemius in chronic stroke patient based on ankle joint degree. The subjects of this study were 10 chronic stroke patients modified Ashworth scale(MAS) 2. Ultrasonographic and dynamometer was measured during resting and maximum voluntary isometric contraction(MVIC) on muscle thickness, pennation angle, fascicle length, MVIC. Result from analysis showed that muscle thickness was thinner in the paretic side than in the non-paretic side(p<.001) and the more plantarflexion increased, the thinner muscle thickness became. And at the time of resting rather than of MVIC significant(p<.001). Result from analysis showed that penneation angle was smaller in the paretic side than in the non-paretic side(p<.001) and the more plantarflexion increased, the larger pennation became. And at the time of resting rather than of MVIC significant(p<.001). Result from analysis showed that fascicle was shorter in the paretic side than in the non-paretic side(p<.001) and the more plantarflexion increased, the shorter fascicle length became. And at the time of resting rather than of MVIC significant(p<.001). The results of this study showed that effect of muscle activity on muscle architectural of medial gastrocnemius in chronic stroke patient based on ankle joint degree. Therefore, Ultrasonographic evaluation of chronic stroke patients according ankle joint degree and muscle activity in the clinical diagnosis and therapy is considered a very useful data.

Use of ultrasonography for improving reproductive efficiency in cows II. Comparative evaluation of ovarian structures using ultrasonography and plasma progesterone analysis in subestrous dairy cows (초음파 진단장치를 이용한 축우의 번식효율증진에 관한 연구 II. 무발정 젖소에서 초음파검사 및 progesterone 농도측정에 의한 난소 구조물의 비교평가)

  • Son, Chang-ho;Kang, Byong-kyu;Choi, Han-sun;Kang, Hyun-gu;Paik, In-seok;Suh, Guk-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.642-651
    • /
    • 1998
  • The accuracy of ultrasonography for determining the presence of a functional corpus luteum in subestrous dairy cows was investigated, using a radioimmunoassay for progesterone in plasma. Luteal status (high or low progesterone concentrations) was diagnosed in 534 cows, using B-mode transrectal ultrasonography. Accuracy of ultrasonography was 96.3% and 88.8% in the cows with and without functional corpus luteum, respectively. In 362 cows diagnosed with functional corpus luteum by ultrasonographic examination, 20 cows were diagnosed with the non-functional corpus luteum by analysis of plasma progesterone concentrations (false positive). In 172 cows with non-functional corpus luteum by ultrasonographic examination, 13 cows were diagnosed with the functional corpus luteum based on plasma progesterone assay (false negative). Most of the corpus luteum with well-defined border and homogeneous echotexture were diagnosed with functional corpus luteum. All cows that were not detected a corpus luteum by ultrasonographic examination were diagnosed as non-functional corpus luteum. The corpus luteum of cows that were diagnosed with false positive appeared homogeneous echotexture and above 15 mm in diameter, but the corpus luteum was the non-functional corpus luteum within Day 5 (Day 0 is ovulation day) or after Day 19. The corpus luteum of cows that were diagnosed with false negative appeared heterogeneous echogenicity and below 15 mm in diameter, but the corpus luteum was the functional corpus luteum after Day 5 or around Day 17. It was concluded that accuracy of ultrasonography was excellent for determining the presence of a functional corpus luteum in subestrous dairy cows. The corpus luteum that was diagnosed with false positive or false negative was the developing or regressing states. Thus, ultrasonography was required a serial examination of two or three times accurately diagnosing these corpus luteum.

  • PDF

Time of Initial Detection of the Gestational Structures by Ultrasonography Examination in Small Pet Dogs (소형 애완견에서 초음파 검사에 의한 임신 구조물의 최초 관찰 시기)

  • Park, Sang-Guk;Kim, Bang-Sil;Yun, Chang-Jin;Yeo, Woon-Chang;Park, Chul-Ho;Kim, Jae-Pung;Lee, Suk-Kyung;Moon, Jin-San;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-ho
    • Journal of Embryo Transfer
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • Serial ultrasonographic examinations were daily performed from 15 days after ovulation until parturition to determine the time of first detection and ultrasonographic appearance of the fetal and extra-fetal structures in pregnant 10 Maltese, 10 Yorkshire Terrier, 15 Shih-tzu, and 10 Miniature Schnauzer bitches, respectively. Gestational age was timed from the day of ovulation (day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0ng/ml. The gestational length was $63.4{\sim}63.6$ (range: $61{\sim}65$) days and the geatational length was no statistically significant difference among bitches (p>0.05). The initial detection of the extra-fetal structures were; gestational sac at days $18.9{\sim}19.5\;(17{\sim}22)$, zonary placenta at days $24.6{\sim}25.5\;(23{\sim}28)$, yolk sac membrane at days $24.6{\sim}25.5\;(23{\sim}27)$, yolk sac tubular shape at days $26.1{\sim}26.3\;(24{\sim}28)$, and amniotic membrane at days $26.1{\sim}28.2\;(24{\sim}31)$, respectively. The time of the first detection of the extra-fetal structures were no statistically significant difference among bitches (p>0.05). The initial detection of the fetal structures were; embryo initial detection at days $22.5{\sim}22.9\;(21{\sim}24)$, heartbeat at days $23.2{\sim}23.8\;(21{\sim}25)$, embryo bipolar shape $27.6{\sim}28.9\;(26{\sim}30)$, fetal movement at days $31.9{\sim}32.8\;(27{\sim}34)$, limb buds at days $29.1{\sim}30.7\;(27{\sim}33)$, stomach at days $31.1{\sim}33.1\;(29{\sim}34)$, urinary bladder at days $32.4{\sim}33.2\;(29{\sim}35)$, skeleton at days $34.7{\sim}35.9\;(34{\sim}39)$, and kidney at days $42.1{\sim}44.7\;(41{\sim}48)$, respectively. The the time of the first detection of the fetal structures were no statistically significant difference among bitches (p>0.05). These results indicate the evaluation of the time of first detection and ultrasonographic characteristics of the gestational structures might be useful for pregnancy diagnosis, estimating fetal age, embryonic resorption, fetal monster, abnormal fetal growth and fetal viability, respectively.

Usefulness of Ultrasonographic Examination in Diagnosis and Follow-up of the Frozen Shoulder (동결견의 진단과 치료 경과 판정에 대한 초음파 검사의 유용성)

  • Choi, Chang-Hyuk;Kim, Seok-Jun;Lee, Sang-Hwa;Kim, Hee-Soo;Shim, Jung-Hyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose: In order to know the effectiveness of ultrasonographic examination in diagnosis and follow-up evaluation for the frozen shoulder, we compared those with contralateral side in initial and after steroid injection. Materials and Methods: For the 20 unilateral frozen shoulder from July 2012 to July 2013, ultrasonographic examination was tried using reference line 1 (CBT: distance from coracoid process to LHB tendon) and line 2 (CBG: distance from coracoid process to bicipital groove). We tried 1 time steroid injection and compared the improvement in gross motion and reference line with 2 month, 4 month, and 6 month's serial ultrasonographic examination. Results: The differences on CBT line between lesion side and normal side were -5.6 mm, -5.0 mm, and -4.3 mm in neutral (Neut), external rotation (ER) and internal rotation (IR), respectively. The differences on CBG line were -6.1 mm, -4.7 mm, and -5.0 mm respectively (p<0.05). The changes in the reference line after steroid injection were evaluated at 2 month (CBT: -4.8 mm, -3.5 mm, -2.6 mm / CBG: -4.7 mm, -4.0 mm, -3.6 mm), 4 month (CBT: -4.7 mm, -3.2 mm, -1.7 mm / CBG: -4.3 mm, -3.7 mm, -1.2 mm), and 6 month (CBT: -1.1 mm, -2.9 mm, -0.5 mm / CBG: -1.2 mm, -0.7 mm, -0.9 mm). The gross motion was improved at 4 month after injection, from elevation $108^{\circ}$, ER $32^{\circ}$, IR L5 in initial to $133^{\circ}$, $42^{\circ}$, L3 respectively (p<0.05). Pain improved from 7.5 in initial to 3.0 at 2 month on visual analog scale (VAS). Conclusion: The serial examination after steroid injection revealed that the delayed improvement on reference line (6 month) compared with pain (2 month) or gross motion (4 month). Dynamic ultrasonogram was useful in diagnosis and follow-up evaluation of frozen shoulder.

  • PDF

The Value of High Resolution Ultrasonography in Diagnosis of Thyroid Nodule (갑상선 결절의 진단에 있어서 고해상능 초음파검사의 가치)

  • Shim Hyung-Jin;Choung Hue-Moon;Yoon Jung-Han;JeGal Young-Jong;Park Jin-Gyoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.2
    • /
    • pp.114-118
    • /
    • 1990
  • A clinical study of 37 cases with thyroid nodules, which were treated by surgical excision and confirmed pathologically at the Department of Surgery, Chonnam National University Medical School, from Dec. 1988 to Feb. 1990, was conducted and following results were obtained in ultrasonographic evaluation of thyroid nodules. 1) The thyroid adenoma were showed well-defined margin, homogenous internal echo and surrounding Halo, but thyroid cancer were showed ill-defined margin, inhomogenous internal echo and no surrounding Halo. 2) The sensitivity of high resoution ultrasonography compared with pathologic diagnosis to thyroid cancer was 87.5%, specificity 94.1%, accuracy 88%, false positive 5.88%, and negative 12.5%.

  • PDF

A Painful Glomus Tumor on the Pulp of the Distal Phalanx

  • Shin, Dong-Keun;Kim, Min-Su;Kim, Sang-Woo;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.185-187
    • /
    • 2010
  • A 52-year-old female patient presented with an 8-year history of progressively intense pain, cold sensitivity, and severe tenderness to palpation of the ulnar side of the tip of her right little finger. Subsequent diagnostic evaluation with ultrasonographic imaging revealed the presence of a glomus tumor in the tender area. Glomus tumors are benign, occurring in the vascular hamartomatous tubercles of the glomus body, which is a myoarterial apparatus typically found in the reticular dermis of the skin. Distal glomus tumors are relatively uncommon, and account for approximately 1% of all hand tumors. Most of them are located in the subungual area because of its high concentration of glomus bodies. We report a case of a glomus tumor with a typical triad of symptoms, yet with a rare location : on the pulp of the ulnar aspect of the distal phalanx of the right little finger.

Radiculopathy Caused by Internal Iliac Artery Pseudoaneurysm Managed with Endovascular Embolization

  • Choi, Il;Im, Soo-Bin;Kim, Bum-Tae;Shin, Won-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.6
    • /
    • pp.484-486
    • /
    • 2007
  • The authors describe a case of pseudoaneurysm arising from internal iliac artery presented with radiculopathy mimicking the symptoms of lumbar disc disease or spinal cord tumor. Among the several preoperative evaluation including CT, MRI, electrophysiologic study and ultrasonography, important diagnostic clue was obtained by ultrasonographic findings of turbulence flow at the core of partially enhanced mass in the pelvic cavity. The patient was managed with endovascular coil embolization successfully. The current case makes us remind that assessment of neurological symptoms on lower extremity should include consideration of extraspinal cause in pelvis.

Subperiosteal Osteoid Osteoma of the Knee: Case Report

  • Suh, Hie Bum;Lee, In Sook;Rhee, Seung Joon;Song, You Seon;Song, Jong Woon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • Osteoid osteoma, a frequent lesions of bone, is usually intraosseous but occasionally subperiosteal. We describe the case of a 19-year-old male with knee pain caused by subperiosteal osteoid osteoma. Radiologic evaluation was performed with radiographic, computed tomography (CT), ultrasonographic (US) and magnetic resonance imaging (MRI). But the preoperative diagnosis of osteoid osteoma was delayed because of unusual imaging findings and atypical symptom. After excisional biopsy, histological examination confirmed the diagnosis of osteoid osteoma. The lesion was treated successfully with CT-guided radiofrequency ablation.

Ultrasonographic evaluation of rotator cuff leison

  • Sugimoto Katsumasa;Matsui Nobuo
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 1995.03a
    • /
    • pp.46-46
    • /
    • 1995
  • We investigated the reliablity of the ultrasonography for diagnosis of rotatar cuff taers. We prepared histological sections of forty shoulder joints In match the ultrasound planes, and conducted a comparative study of tke two sets of images. hi cases of rotator cuff tear, hyperechogenic and cartilaginfication of the tear site were detected as hyperechogenic foci. On the countrary, the regions in which tendon fibers were decreased or absent showed sonolucent areas. We caluculated the echo level of rotator cuff objectively. The area of abnormal echo level and the other regions located in the same depth of the rotator cuff were defined by ultrasonic equipment. The mein difference in these two echo levels was calculated. The mean difference in patients with rotator cuff tears was larger than that in normal cases. These results indicate that ultrasonography is a useful procedure in many patients with rotator cuff lesions.

  • PDF