• Title/Summary/Keyword: Ultrasonic therapy

검색결과 73건 처리시간 0.13초

한의 치료로 호전된 경추성 현훈 환자 치험 3예 (Three Cases of Cervical Vertigo Improved by Traditional Korean Medicine Treatment)

  • 최성환;강신우;박현선;박서현;금동호
    • 한방재활의학과학회지
    • /
    • 제32권1호
    • /
    • pp.145-155
    • /
    • 2022
  • The purpose of this study is to evaluate the effectiveness of traditional Korean medicine treatment of cervical vertigo. Three patients were diagnosed as cervical vertigo with correlating symptoms of imbalance and dizziness with neck pain. The diagnosis of cervical vertigo is also dependent on excluding other vestibular disorders on the basis of history, examination, and vestibular function tests. They were treated by acupuncture, transcutaneous electrical nerve stimulation therapy and low-intensity pulsed ultrasound at acupoints and sympathetic ganglion chain of their cervical and upper thoracic region. The evaluation of clinical outcome was done by numeric rating scale (NRS), dizziness handicap inventory (DHI) and neck disability index (NDI), EuroQol-five dimensions questionnaire (EQ-5D) index. After the treatment, the value of their NRS, NDI, DHI was significantly decreased and their EQ-5D index was significantly increased. The traditional Korean medicine treatment at cervical and upper thoracic region could be an effective way to treat cervical vertigo.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.316-324
    • /
    • 2004
  • 목적 : 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사 체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 대상 및 방법 : 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range $3\~3$ m), Computer (RS232C), Sewo Motor (Torque 2.3 Kg) 등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 결과 : 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}1\%$ 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 $2.34{times}10^{-4}$초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 결론 : 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}1\%$ 이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34H10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

불안정한 지지면 위에서의 플랭크 운동이 만성허리통증환자의 유연성, 배 근육 두께 및 통증에 미치는 영향 (The Effect of Unstable Support Surface Plank Exercise on Flexibility, Abdominal Muscle Thickness and Pain in Chronic Low Back Pain)

  • 한우정;손경현
    • 대한물리치료과학회지
    • /
    • 제26권3호
    • /
    • pp.23-36
    • /
    • 2019
  • Background: The purpose of this study was to investigate the effect of Plank exercise on unstable support surfaces on flexibility, abdominal muscle thickness and pain in patients with chronic back pain. Design: Randomized controlled trial. Methods: This study was performed on 16 patients with chronic back pain of ◯◯ military unit. Sixteen subjects were randomly assigned into two groups, an upper extremity trainer group (group I, n=8) and a lower extremity trainer group (group II, n=8). The subjects in group I carried out Flank exercise applying the stability trainer to their upper extremities and ones in group II carried out the same exercise applying the stability trainer to their lower extremities for 4 weeks. In order to ascertain the difference between two groups, flexibility, abdominal muscle thickness and pain were measured before and after the exercise. The flexibility was measured by sit and reach test, the thickness of the abdominal muscle was measured by using ultrasonic imaging equipment, and the pain was measured by the visual analogue scale. A paired t-test was utilized to compare changes in pain, abdominal muscle thickness and flexibility before and after flank exercise on unstable support surfaces. Analysis of Covariance (ANCOVA) was performed for ascertaining the significant differences between groups. The significance level was set by α=.05. Results: 1) The flexibilities of two groups were increased after the exercise (p<0.05). 2) In both groups, the thicknesses of rectus abdominis, external oblique abdominis, internal oblique abdominis, and transverse abdominis were all increased after the exercise (p<0.05). 3) The pains in both groups were decreased after the exercise (p<0.05). 4) In the comparisons of two groups, there were no differences in the flexibility, thickness of external oblique abdominis, internal oblique abdominis and transverse abdominis and pain (p>0.05). Whereas only thickness of Rectus abdominis was larger in the group I than in the group II (p<0.05). Conclusion: Plank exercise on the unstable support surface for 4 weeks resulted in increased flexibility, abdominal muscle thickness and pain reduction in patients with chronic back pain. Therefore, it is considered that performing flank exercise on the unstable supporting surface is suitable for the reduction of the pain in patients with chronic back pain. However, in this study, it is considered that continuous and diverse studies are needed because there was not a large difference between the groups when the upper or lower limbs are provided unstable support surfaces.

초음파와 LED를 이용한 일체형암세포 증식억제 모듈의 기초연구 (Basic study on proliferation control of cancer cells using combined ultrasound and LED therapeutic module)

  • 조경래;최세운
    • 한국정보통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1107-1113
    • /
    • 2018
  • 최근 들어 초음파를 활용한 항암 치료법은 미세한 기포 또는 조영제를 환자에게 주입한 후 특정 주파수의 초음파를 발생시켜 세포의 괴사를 유도하는 치료법으로서, 항암치료 중 발생가능한 부작용을 현저히 감소시킬 수 있는 유용한 치료법으로 제안되고 있다. 이는 정기적인 세포의 사멸은 세포의 손상과 관계없이 필수적인 생물학적 프로세스이며, 초음파는 이러한 세포의 사멸을 유도 또는 증폭시키는 효과가 있기 때문으로 알려져 왔다. 한편, 광 역학 치료는 광원의 고유한 파장에 따라 반응하는 광감응제 등과 같은 화합물을 추가적으로 인체에 주입함으로써 특정 암세포의 괴사 유도가 가능하며 이를 위해 다양한 종류의 레이저 사용이 가능하다. 하지만, 고가의 광원과 대형화된 장비, 광원의 자극으로 인한 발열 현상 등의 한계로 제한적인 사용이 가능하여왔다. 이러한 기술적 한계는 소형 발광 다이오드가 개발됨에 따라 광 역학 치료 장비의 소형화와 발열현상의 제어가 가능하게 되었고, 그 결과 발광 다이오드는 레이저의 대체광원으로 인식되었다. 따라서, 본 논문에서는 의료용으로 광범위하게 사용되며, 부작용이 적고, 비교적 저주파인 1 MHz 초음파 발생장치와 저렴한 발광다이오드를 복합적으로 융합한 일체형 암세포 증식억제 모듈을 개발하고 이를 암세포에 적용시켜 효과를 정량적으로 분석하고자 한다.

협부에 전이된 지방육종의 치험례 (METASTASIZED LIPOSARCOMA IN THE CHEEK : A CASE REPORT)

  • 김우철;홍락원;김태훈;문선혜;박노부;이용오
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제16권3호
    • /
    • pp.309-314
    • /
    • 1994
  • 지방육종은 주로 근간 간엽조직으로부터 발생되어지며, 중년이상의 남성에서 호발하고 주된 발병부위는 하지 및 후복막강이고 구강 주위조직에 이환되는 경우는 극히 드문 악성종양이며, 본 증례에서는 4년 전 좌측 하지에서 발생되어 우측 하지 및 좌측 협부에 전이된 것으로 생각되어지는 점액양의 지방육종으로 종물의 외과적 절제술 및 화학요법을 시행하였고 장기적인 관찰이 요구된다.

  • PDF

팔굽관절 각도가 악력과 위팔노근 두께에 미치는 영향 (The effects of grasp strength and brachioradialis thickness in elbow joint angle)

  • 박정아
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2073-2078
    • /
    • 2015
  • 본 연구에서는 선 자세에서 팔굽관절 각도에 따른 악력과 위팔노근의 두께 변화를 확인하여 팔굽관절 각도가 악력에 미치는 영향을 알아보고자 하였다. 연구를 위해 건강한 대학생 30명을 선별한 후, 선 자세에서 팔굽관절 $0^{\circ}$, $90^{\circ}$, $135^{\circ}$ 굽힘을 취하게 하고 각각의 최대악력과 위팔노근 두께를 전자악력계와 초음파 영상 진단 장비를 이용하여 측정하였다. 그 결과 남자 대학생과 여자대학생 모두 팔굽관절 각도가 $0^{\circ}$일 때 악력이 가장 컸으며, 각도가 증가할수록 악력이 감소하였으나, 통계적으로 유의미한 차이는 없었다(p<.05). 남자대학생과 여자대학생 모두 팔굽관절 각도가 $0^{\circ}$일 때 위팔노근의 두께가 가장 작았으며, 각도가 증가할수록 위팔노근의 두께가 증가하였으며 통계적으로 유의미한 차이가 있었다(p<.05). 본 연구의 결과를 통해 팔굽관절 각도변화가 악력에는 큰 영향을 미치지 않으나, 위팔노근의 두께에는 영향을 미친다는 것을 알 수 있었다.

체외수정시술을 위한 성선자극호르몬 과배란유도에 Poor Response를 나타낸 환자에서 GnRH Analogue의 사용 (GnRH Analogue in Controlled Ovarian Hyperstimulation for Gonadotropin Poor Responder)

  • 김선행;이희경;구병삼
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제20권1호
    • /
    • pp.37-43
    • /
    • 1993
  • In 27 patients with the past history of poor response to the gonadotropin superovulation induction due to poor follicular growth or permature surge of endogenous luteinizing hormone, the effectiveness of pituitary supperssion with the gonadotropin releasing hormone agonist(GnRH-a) in in vitro fertilization(IVF) program was evaluated in 43 cycles using a combination regimen of D-Trp-6 LHRH(Decapeptyl, Ferring)and FSH/hMG from June, 1989 to August, 1990 at Korea University Hospital IVF Clinic. At midluteal phase of menstrual cycle, Decapeptyl-CR was administered by long-term protocol to minimize initial agonistic effect of endogenous gonadotropins. After the confirmation of pituitary suppression, about 2-3 weeks after GNRH-a administration, ovarian follicle growth was stimulated with FSH/hMG and followed by transvaginal ultrasonic measurement of follicle size and by monitoring of serm E2 and LH if necessary. When compared with the control group stimulated with gonadotropin regimen only, the cancellation rate and occurrence rate of premature LH surge during gonadotropin treatment were significantly lower in study group(11.6% and 2.4%, respectively). There is no significant differences in the mean number of aspirated oocytes, fertilization/cleavage rate, embryo transfer(ET) rate, and mean number of embryos transferred between the two groups. The pregnancy rate per treatment cycle, 16.3%, and per ET cycle, 23.3%, were significantly higher in the study group compared with those of control group. These data suggest that GnRH-a therapy is effective for previous poor responder In gonadotropin superovulation induction for IVF.

  • PDF

대학생의 배가로근과 뭇갈래근 두께와 척추정렬간의 상관관계 (Correlations between the Muscle Thickness of the Transverse Abdominis and the Multifidus Muscle with Spinal Alignment in College Students)

  • 임재헌
    • PNF and Movement
    • /
    • 제12권4호
    • /
    • pp.243-248
    • /
    • 2014
  • Purpose: The transverse abdominis and themultifidus muscle are located in the core. They surround one's trunk and help in body stabilization. Specifically, they control spine articulation to maintain posture and balance. Therefore, weakened deep muscle in the trunk may cause spinal malalignment. This study aims to compare the correlation between the thickness of the transverse abdominis and the multifidus muscle and the spine alignment among college students in their 20s. Methods: This study measured the thickness of the transverse abdominis and the multifidus muscle of 42 healthy college students in their 20s using ultrasonic waves. The thickness of the muscle was measured for the length of the cross-section except for fascia. The thickness of the left and right muscles was measured, and the mean value was calculated. As the thickness of the transverse abdominis can increase because of pressure during exhalation, it was measured at the last moment of exhalation. Spinal alignment was measured by the kyphosis angle, lordosis angle, pelvic tilt, trunk inclination, lateral deviation, trunk imbalance, and surface rotation using Formetric III, which is a three-dimensional imaging equipment. They were measured for three times, and the mean values were calculated. The general characteristics of the subjects were analyzed using descriptive statistics. The correlations between each factor were analyzed using Pearson's correlation analysis. Results: The transverse abdominis showed asignificant correlation with trunk inclination (p<.05). The multifidus muscle showed a significant positive correlation with pelvic tilt and a negative correlation with surface rotation (p<.05). Conclusion: The thickness of transverse abdominis and the multifidus muscle appears to influence spinal alignment. Specifically, the multifidus muscle, which plays an important role on the sagittal plane, influences surface rotation, thus making it an important muscle for scoliosis patients. Therefore, a strengthening training program for the transverse abdominis and the multifidus muscle is necessary according to specific purposes among adults with spinal malalignment.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템 (Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit)

  • 김범수;이정주;남경원;정기석;안치범;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.