• 제목/요약/키워드: Ultrasonic method

검색결과 2,085건 처리시간 0.025초

실시간 모니터링을 통한 레일절손 검지에 관한 연구 (A Study of Detecting Broken Rail using the Real-time Monitoring System)

  • 김태건;엄범규;이희성
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.1-7
    • /
    • 2013
  • Train accidents can be directly connected to fatal accidents-collision, derailment, Fire, railway crossing accidents-resulting in tremendous human casualties. First of all, the railway derailment is not only related to most of railway accidents but also it can lead to much more catastrophic accompanying train overtured than other factors. Therefore, it is most important factor to ensure railway safety. some foreign countries have applied to the detector machines(e.g., ultrasonic detector car, sleep mode, current detector, optical sensing, optical fiber). Since it was developed in order to prevent train from being derailed. In korea, the existing track method has been used to monitor rail condition using track circuit. However, we found out it impossible for Communication Based Train Control system(CBTC), recent technology to detect rail condition using balise(data transmission devices) without no track circuit. For this reason, it is needed instantly to develop real-time monitoring system used to detect broken rails. Firstly, this paper presents domestic and international statues analysis of rail breaks technology. Secondly, the composition and the characteristics of the real-time monitoring system. Finally, the evidence that this system could assumed the location and type of broken rails was proved by the experiment of prototype and operation line tests. We concluded that this system can detect rail break section in which error span exist within${\pm}1m$.

18게이지 천자침을 이용한 경피신루설치술 (Percutaneous Nephrostomy Using 18 Guage Puncture Needle)

  • 김재운;김진우;조재호;장재천;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제15권1호
    • /
    • pp.159-163
    • /
    • 1998
  • 영남대학교 의과대학 부속병원에서 1995년 3월부터 1997년 6월까지 수신증이 있는 58명의 환자, 98례에서 초음파 유도하에 18게이지 천자침으로 직접 신배를 천자하여 경피신루설치술을 시술하였다. 수신증의 원인은 악성 종양에 의한 협착이 65례였으며 이 중 자궁경부암이 가장 많았으며 양성 협착은 25례로 결석, 결핵, 수술에 의한 요관 손상 등의 순위였고, 원인을 알 수 없는 협착이 8례 있었다. 전 예에서 성공적으로 경피신루를 설치하였다. 시술의 합병증은 7.1%로 기존의 21게이지 세침을 이용한 시술과 비슷하였다. 저자들이 시술한 18게이지 천자침을 이용한 경피신루설치술은 21게이지 세침으로 천자하고 0.018인치 유도 철사와 외피가 있는 19게이지 도관을 사용하는 기존의 시술에 비해 시술의 단계를 간략화하여 시간과 비용을 줄일 수 있을 뿐 아니라 합병증의 발생빈도가 높지 않은 안전한 시술로써 유소아나 수신증이 아주 경미한 경우 등을 제외한 수신증에서 기존의 시술을 대치 할 수 있을 것으로 생각된다.

  • PDF

부자식 수위계를 위한 이동형 교정시스템의 수학 모델 (Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters)

  • 홍성택;신강욱
    • 한국정보통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.1964-1972
    • /
    • 2017
  • K-water에서는 2008년부터 부자식 및 초음파, 레이다식의 수위계에 대한 ISO 17025 국제공인 교정기관을 운영하고 있다. 현재까지 수위계의 교정은 고정표준실에서 실내 교정만이 가능하였으며, 이는 현장 등의 실외에서 교정하는 시스템의 부재가 원인이었다. 따라서 현장에서도 교정이 가능하도록 2015년에 이동형 교정시스템을 개발하였으며, 2016년에 각종 심사 및 위원회를 거쳐 한국인정기구(KOLAS)로부터 인정을 받았다. 본 논문에서는 한국인정기구로부터 인정받은 수위계 이동형 교정시스템 중 부자식 수위계를 현장에서 교정할 수 있는 교정시스템에 대하여 표준기 및 측정과 관련한 제반 사항에 대하여 검토하였다. 또한 설계의 기반이 되는 수학 모델을 도출하였으며, 이동형 교정시스템 구축을 통하여 수문관측 데이터에 대한 과학적인 시스템 운영으로 측정 데이터의 신뢰성을 확보하고자 하였다.

조영증강 초음파 진단에서 파라미터 영상 생성 및 개선 기법 (Parametric Image Generation and Enhancement in Contrast-Enhanced Ultrasonography)

  • 김신해;이은림;조은비;김호준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제6권4호
    • /
    • pp.211-216
    • /
    • 2017
  • 본 논문에서는 조영증강 초음파 진단시스템에서 유용성과 성능을 개선하기 위한 영상처리 기법을 제안한다. 의료초음파 영상에서 진단 파라미터 데이터를 가시화 하는 방법론으로서 연속적인 픽셀 값을 갖는 전이시간 데이터의 표현과, 4가지 유형의 값으로 분류되는 병변 진단 파라미터 영상을 생성하는 방법을 제시한다. 또한 생성된 파라미터 영상에서 노이즈를 제거하기 위한 방법론으로서 MRF 모델을 이용한 영상개선 기법을 제안한다. 이러한 파라미터 영상 생성기법은 초음파 진단 데이터에서 조영증강 패턴의 동적인 변화에 대한 육안 판별의 한계를 극복할 수 있게 한다. 제안된 방법은 원영상에서 영역의 윤곽선을 명확하게 하며 4가지 색상을 통하여 병변의 특성에 관한 시각적 판단을 용이하게 한다. MRF기반 영상개선 과정에서 연속적인 픽셀 값에 대한 에너지함수를 정의하고 이를 최적화 하는 기법을 개발하였으며 실제 의료영상을 사용한 실험을 통하여 제안된 이론의 유용성을 평가하였다.

속초 신흥사 목조지장보살삼존상의 비파괴 손상도 진단 (Nondestructive Deterioration Diagnosis for Wooden Ksitigarbha Triad Statues of Shinhungsa Temple in Sokcho, Korea)

  • 한나라;이찬희;이정은
    • 보존과학회지
    • /
    • 제29권2호
    • /
    • pp.93-102
    • /
    • 2013
  • 속초 신흥사 목조지장보살삼존상(보물 제1749호)은 신흥사 명부전에 안치되어 있다. 이 삼존상에는 부분적으로 균열, 박락 등의 물리적 손상과 안료 변색, 균류 서식 등의 화학적 및 생물학적 손상이 발생하였다. 이 연구에서는 삼존상의 손상도 평가 및 보존계획을 수립하기 위해 손상지도 작성, 초음파 측정, X-선 및 내시경 촬영 등의 비파괴 정밀진단을 수행하였다. 이 결과, 지장보살에서는 개금층 박락이 관찰되며 각종 오염물이 불상표면에 고착되어 있다. 무독귀왕은 누수에 의한 안료변색이 심하다. 도명존자는 노출된 목부재에서 곤충의 서식흔적이 확인되었으며, 내부에서는 벌집이 관찰되었다. 따라서 이 손상도 진단 결과를 바탕으로 삼존상의 원형을 보존하기 위한 보수가 필요한 것으로 판단된다.

연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가 (Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images)

  • 이소희;김종운;이수열;류정원;최동혁;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권5호
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

어종식별을 위한 광대역 초음파 변환기의 설계 -I - 전극분할형 압전진동자의 주파수특성 제어 - (The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Control of the Resonance Frequency of a Piezoelectric Transducer with Two Pair of Electodes -)

  • 이대재
    • 수산해양기술연구
    • /
    • 제33권3호
    • /
    • pp.183-188
    • /
    • 1997
  • 어종의 식별을 위한 음향학적 정보를 추출해 내는 데 활용하기 위한 초음파 변환기를 설계하기 위한 시도의 하나로꺼 전극분할 원반형 압전진동자를 이용하여 공진주파기를 가변시켜 넓은 주파수 대역에 걸쳐 사용할 수 있는 어군탐지기용 송.수파기를 설계하였다. 본 연구에서 설계한 초음파 변환기는 전극분할형 압전진동자의 한쪽 전극에 발전기를 접속하고, 다른 쪽 전국에 2.7~15.0 mH 인덕턴스를 접속하였을 때, 경방향에 대한 공진 주파스는 49.5~ 55.7 kHz의 범위에서 가변시킬 수 있었고, 또한 외부에서 진동자에 인가한 임피던스의 영향에 의해 출현하는 공진주파수에는 61.3~121.7 kHz의 범위에서 가변시킬수 있었다. 그러나, 이들 주파수에 대한 전기음향효율을 고려 할때, 실제로 활용할 수 있는 주파수 범위는 이것보다 훨씬 좁은 폭이 될 것이라 판단된다.

  • PDF

잉크젯을 이용한 디스플레이 생산을 위한 회전 미러 방식의 잉크젯 액적 모니터링 장비 및 측정법 연구 (High-Speed Monitoring Device to Inspect Inkjet Droplets with a Rotating Mirror and Its Measuring Method for Display Applications)

  • 신동윤
    • 대한기계학회논문집A
    • /
    • 제41권6호
    • /
    • pp.525-532
    • /
    • 2017
  • 차세대 주력 디스플레이인 유기 및 양자점 발광 다이오드를 잉크젯을 이용하여 저렴한 비용으로 생산하기 위한 연구개발이 진행되어 왔으며, 잉크 액적의 토출 신뢰성을 고속으로 검사하기 위한 모니터링 장비의 개발이 요구된다. 본 연구에서는 기존 직선 운동 방식의 잉크젯 모니터링 장비 대신에 로터리 및 리니어 초음파 모터를 이용하여 미러를 회전시킴으로써 노즐들에서 토출되는 잉크 액적들을 모니터링할 수 있는 장비를 개발하여 측정 능력을 시험하였다. $10{\mu}m$, $30{\mu}m$$50{\mu}m$ 직경 원형의 측정 오차는 각각 $0.5{\pm}1.0{\mu}m$, $-1.2{\pm}0.3{\mu}m$$0.2{\pm}0.5{\mu}m$였다. 모니터링 시간은 17초가 소요되었으며, 제어 프로그램의 최적화를 통해 8.6초까지 모니터링 시간을 단축할 수 있는 가능성을 확인하였다.

Comparative analysis of the wind characteristics of three landfall typhoons based on stationary and nonstationary wind models

  • Quan, Yong;Fu, Guo Qiang;Huang, Zi Feng;Gu, Ming
    • Wind and Structures
    • /
    • 제31권3호
    • /
    • pp.269-285
    • /
    • 2020
  • The statistical characteristics of typhoon wind speed records tend to have a considerable time-varying trend; thus, the stationary wind model may not be appropriate to estimate the wind characteristics of typhoon events. Several nonstationary wind speed models have been proposed by pioneers to characterize wind characteristics more accurately, but comparative studies on the applicability of the different wind models are still lacking. In this study, three landfall typhoons, Ampil, Jongdari, and Rumbia, recorded by ultrasonic anemometers atop the Shanghai World Financial Center (SWFC), are used for the comparative analysis of stationary and nonstationary wind characteristics. The time-varying mean is extracted with the discrete wavelet transform (DWT) method, and the time-varying standard deviation is calculated by the autoregressive moving average generalized autoregressive conditional heteroscedasticity (ARMA-GARCH) model. After extracting the time-varying trend, the longitudinal wind characteristics, e.g., the probability distribution, power spectral density (PSD), turbulence integral scale, turbulence intensity, gust factor, and peak factor, are comparatively analyzed based on the stationary wind speed model, time-varying mean wind speed model and time-varying standard deviation wind speed model. The comparative analysis of the different wind models emphasizes the significance of the nonstationary considerations in typhoon events. The time-varying standard deviation model can better identify the similarities among the different typhoons and appropriately describe the nonstationary wind characteristics of the typhoons.

환경시료 중 폴리브롬화비페닐(Polybrominated Biphenyls) 분석법 (Method for the Analysis of Polybrominated Biphenyls(PBBs) in Environmental Samples)

  • 신선경;김태승;황승율;이원석;정영희;나진균
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.300-316
    • /
    • 2002
  • 수질 및 토양 시료 중의 PBBs의 분석방법 확립을 위해 표준물질이 준비된 PBBs 22종을 대상으로 추출 및 정제 등의 전처리 회수율 및 검출한계를 환경시료로부터 얻었다. PBBs의 시료 추출법으로 액/액, 속실렛, 초음파 추출법을 적용하였고, 실리카겔, 플로리실 정제컬럼의 적용성 검토 후 GC/MS로 분석하였다. 수질 시료의 경우 검출한계는 브롬화된 정도에 따라 약간의 차이를 보였고 5~10 ng/L이었으며, n-hexane, dichloromethane 및 toluene 등의 단일 용매의 평균회수율은 96~107%, n-hexane:acetone (1:1) 및 (9:1)의 혼합용매의 평균 회수율은 60~80%로 나타났다. 또한, 토양 시료의 경우 검출한계는 0.5~3.5 ng/g이었으며, 선정 용매의 평균 회수율은 속실렛 추출이 67~97% 및 초음파 추출이 64~76%로 나타났다.